@@ -1,441 +1,339
1 [Tester]
1 [Tester]
2 TesterType = "HSMP2"
2 TesterType = "SMP3"
3 TesterName = "Hochstrommessplatz 2"
3 TesterName = "Strommessplatz 3"
4 MaxCurrent = 2000
4 MaxCurrent = 130
5 MaxTemperature = 250
5 MaxTemperature = 250
6 MaxAmbientTemperature = 50
6 MaxAmbientTemperature = 50
7 TemperatureWarning- = 10
7 TemperatureWarning- = 10
8 SensorsEnable.<size(s)> = "15"
8 SensorsEnable.<size(s)> = "15"
9 SensorsEnable 0 = "True"
9 SensorsEnable 0 = "True"
10 SensorsEnable 1 = "True"
10 SensorsEnable 1 = "True"
11 SensorsEnable 2 = "True"
11 SensorsEnable 2 = "True"
12 SensorsEnable 3 = "True"
12 SensorsEnable 3 = "True"
13 SensorsEnable 4 = "True"
13 SensorsEnable 4 = "True"
14 SensorsEnable 5 = "True"
14 SensorsEnable 5 = "True"
15 SensorsEnable 6 = "True"
15 SensorsEnable 6 = "True"
16 SensorsEnable 7 = "True"
16 SensorsEnable 7 = "True"
17 SensorsEnable 8 = "True"
17 SensorsEnable 8 = "False"
18 SensorsEnable 9 = "True"
18 SensorsEnable 9 = "False"
19 SensorsEnable 10 = "False"
19 SensorsEnable 10 = "False"
20 SensorsEnable 11 = "False"
20 SensorsEnable 11 = "False"
21 SensorsEnable 12 = "False"
21 SensorsEnable 12 = "False"
22 SensorsEnable 13 = "False"
22 SensorsEnable 13 = "False"
23 SensorsEnable 14 = "False"
23 SensorsEnable 14 = "False"
24 SensorsDescription.<size(s)> = "15"
24 SensorsDescription.<size(s)> = "15"
25 SensorsDescription 0 = "NI-9212: Ch0"
25 SensorsDescription 0 = "NI-9210: Ch0"
26 SensorsDescription 1 = "NI-9212: Ch1"
26 SensorsDescription 1 = "NI-9210: Ch1"
27 SensorsDescription 2 = "NI-9212: Ch2"
27 SensorsDescription 2 = "NI-9210: Ch2"
28 SensorsDescription 3 = "NI-9212: Ch3"
28 SensorsDescription 3 = "NI-9210: Ch3"
29 SensorsDescription 4 = "NI-9212: Ch4"
29 SensorsDescription 4 = "NI-9219: Ch0"
30 SensorsDescription 5 = "NI-9212: Ch5"
30 SensorsDescription 5 = "NI-9219: Ch1"
31 SensorsDescription 6 = "NI-9212: Ch6"
31 SensorsDescription 6 = "NI-9219: Ch2"
32 SensorsDescription 7 = "NI-9212: Ch7"
32 SensorsDescription 7 = "NI-9219: Ch3"
33 SensorsDescription 8 = "NI-9219_1: Ch0"
33 SensorsDescription 8 = ""
34 SensorsDescription 9 = "NI-9219_1: Ch1"
34 SensorsDescription 9 = ""
35 SensorsDescription 10 = "NI-9219_1: Ch2"
35 SensorsDescription 10 = ""
36 SensorsDescription 11 = "NI-9219_2: Ch0"
36 SensorsDescription 11 = ""
37 SensorsDescription 12 = "NI-9219_2: Ch1"
37 SensorsDescription 12 = ""
38 SensorsDescription 13 = "NI-9219_2: Ch2"
38 SensorsDescription 13 = ""
39 SensorsDescription 14 = "NI-9219_2: Ch3"
39 SensorsDescription 14 = ""
40 VoltageDescription.<size(s)> = "5 2"
40 VoltageDescription.<size(s)> = "5 2"
41 VoltageDescription 0 = "NI-9215: Ch0"
41 VoltageDescription 0 = "NI PXI-6281: Ch3"
42 VoltageDescription 1 = "Pr�flingsspannung [V]"
42 VoltageDescription 1 = "Pr�flingsspannung [V]"
43 VoltageDescription 2 = "NI-9219_1: Ch2"
43 VoltageDescription 2 = "NI PXI-6281: Ch4"
44 VoltageDescription 3 = "Zero Flux- Spannung [V]"
44 VoltageDescription 3 = "Shunt- Spannung [V]"
45 VoltageDescription 4 = ""
45 VoltageDescription 4 = ""
46 VoltageDescription 5 = "Strom [A]"
46 VoltageDescription 5 = "Strom [A]"
47 VoltageDescription 6 = ""
47 VoltageDescription 6 = ""
48 VoltageDescription 7 = "Widerstand [mOhm]"
48 VoltageDescription 7 = "Widerstand [mOhm]"
49 VoltageDescription 8 = ""
49 VoltageDescription 8 = ""
50 VoltageDescription 9 = "Leistung [W]"
50 VoltageDescription 9 = "Leistung [W]"
51 CalibrationPassword = "48c8947f69c054a5caa934674ce8881d02bb18fb59d5a63eeaddff735b0e9801e87294783281ae49fc8287a0fd86779b27d7972d3e84f0fa0d826d7cb67dfefc"
51 CalibrationPassword = "48c8947f69c054a5caa934674ce8881d02bb18fb59d5a63eeaddff735b0e9801e87294783281ae49fc8287a0fd86779b27d7972d3e84f0fa0d826d7cb67dfefc"
52
52
53 [Hardware]
53 [Hardware]
54 SimulateDevices = False
54 SimulateDevices = True
55 DI_E-Stop = ""
55 DI_E-Stop = "PXI1Slot5/port0/line5"
56 DI_Setup = ""
56 DI_Setup = "PXI1Slot5/port0/line4"
57 PowerSupply_VISAName = "TCPIP0::10.1.2.40::30000::SOCKET"
57 PowerSupply_VISAName = "COM4"
58 PowerSupply_Address = "0"
58 PowerSupply_Address = "1"
59 PowerSupply_Baudrate = "0"
59 PowerSupply_Baudrate = "9600"
60 PowerSupply_OutputVoltage = "10,000000"
60 PowerSupply_OutputVoltage = "5,500000"
61 PowerSupply_OverVoltageProtection = "9,800000"
61 PowerSupply_OverVoltageProtection = "6,000000"
62 PowerSupply_MinCurrent = "0"
62 PowerSupply_MinCurrent = "0"
63 PowerSupply_Check = False
63 PowerSupply_Check = False
64 PowerSupply_WarningPower = "4000,000000"
64 PowerSupply_WarningPower = "200,000000"
65 PowerSupply_AbortPower = "5000,000000"
65 PowerSupply_AbortPower = "250,000000"
66 PowerSupply_PID = "FALSE"
66 PowerSupply_PID = "False"
67 PowerSupply_PID_Time = "1,000000"
67 PowerSupply_PID_Time = "0,100000"
68 PowerSupply_PID_ProportionalGain = "0,100000"
68 PowerSupply_PID_ProportionalGain = "0,100000"
69 PowerSupply_PID_IntegralTime = "0,180000"
69 PowerSupply_PID_IntegralTime = "0,180000"
70 PowerSupply_PID_DerivativeTime = "0,000000"
70 PowerSupply_PID_DerivativeTime = "0,000000"
71 AbortCurrentDifference = "0,000000"
71 AbortCurrentDifference = "50"
72 Measurement_Channels.<size(s)> = "17"
72 Measurement_Channels.<size(s)> = "17"
73 Measurement_Channels 0 = "NI9215/ai0"
73 Measurement_Channels 0 = "PXI1Slot5/ai4"
74 Measurement_Channels 1 = "NI9219_1/ai2"
74 Measurement_Channels 1 = "PXI1Slot5/ai5"
75 Measurement_Channels 2 = "NI9212/ai0"
75 Measurement_Channels 2 = "NI9210/ai0"
76 Measurement_Channels 3 = "NI9212/ai1"
76 Measurement_Channels 3 = "NI9210/ai1"
77 Measurement_Channels 4 = "NI9212/ai2"
77 Measurement_Channels 4 = "NI9210/ai2"
78 Measurement_Channels 5 = "NI9212/ai3"
78 Measurement_Channels 5 = "NI9210/ai3"
79 Measurement_Channels 6 = "NI9212/ai4"
79 Measurement_Channels 6 = "NI9219/ai0"
80 Measurement_Channels 7 = "NI9212/ai5"
80 Measurement_Channels 7 = "NI9219/ai1"
81 Measurement_Channels 8 = "NI9212/ai6"
81 Measurement_Channels 8 = "NI9219/ai2"
82 Measurement_Channels 9 = "NI9212/ai7"
82 Measurement_Channels 9 = "NI9219/ai3"
83 Measurement_Channels 10 = "NI9219_1/ai0"
83 Measurement_Channels 10 = ""
84 Measurement_Channels 11 = "NI9219_1/ai1"
84 Measurement_Channels 11 = ""
85 Measurement_Channels 12 = "NI9219_1/ai2"
85 Measurement_Channels 12 = ""
86 Measurement_Channels 13 = "NI9219_2/ai0"
86 Measurement_Channels 13 = ""
87 Measurement_Channels 14 = "NI9219_2/ai1"
87 Measurement_Channels 14 = ""
88 Measurement_Channels 15 = "NI9219_2/ai2"
88 Measurement_Channels 15 = ""
89 Measurement_Channels 16 = "NI9219_2/ai3"
89 Measurement_Channels 16 = ""
90 Measurement_Sample = "<size(s)=17> 40,000000 40,000000 2,000000 2,000000 2,000000 2,000000 2,000000 2,000000 2,000000 2,000000 40,000000 40,000000 40,000000 40,000000 40,000000 40,000000 40,000000"
90 Measurement_Sample = "<size(s)=17> 1,000000 1,000000 2,000000 2,000000 2,000000 2,000000 40,000000 40,000000 40,000000 40,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000"
91 ShuntResistance = "0,005"
91 ShuntResistance = 0,001
92 Measurement_Check = False
92 Measurement_Check = False
93 Measurement_Delay = "1"
93 Measurement_Delay = "1"
94 DMM_VISAName = "NI9219_1/ai3"
94 DMM_VISAName = "PXI1Slot3"
95 DMM_ContactLimits = "<size(s)=2> -1,000000 1,000000"
95 DMM_ContactLimits = "<size(s)=2> 0,0 1,0"
96 TemperatureGain = "<size(s)=15> 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000"
96 TemperatureGain = "<size(s)=15> 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000"
97 TemperatureOffset = "<size(s)=15> 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000"
97 TemperatureOffset = "<size(s)=15> 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000"
98 VoltageGain = "<size(s)=5> 1,000000 -1,000000 1,000000 1,000000 1,000000"
98 VoltageGain = "<size(s)=5> 1,000000 1,000000 1,000000 1,000000 1,000000"
99 VoltageOffset = "<size(s)=5> 0,000000 0,000000 0,000000 0,000000 0,000000"
99 VoltageOffset = "<size(s)=5> 0,000000 0,000000 0,000000 0,000000 0,000000"
100 AllowedContactFails = "2"
100 AllowedContactFails = "2"
101
101
102 [HSMP2]
102 [SMP3]
103 DMM_Configuration.Maximum = "10500,000000"
103 DMM_Function = "2-wire Resistance"
104 DMM_Configuration.Minimum = "0,000000"
104 DMM_AutoRange = False
105 DMM_Configuration.Configuration = "4-Wire"
105 DMM_Range = "0,020000"
106 DMM_Configuration.CurrentExcitationSource = "Internal"
106 DMM_Resolution = "0,001000"
107 DMM_Configuration.CurrentExcitationValue = "0,000500"
108 DMM_Sample = "40,000000"
109 Configuration_AI_Voltage.<size(s)> = "2"
107 Configuration_AI_Voltage.<size(s)> = "2"
110 Configuration_AI_Voltage 0.Maximum = "10,000000"
108 Configuration_AI_Voltage 0.Maximum = "5,000000"
111 Configuration_AI_Voltage 0.Minimum = "-10,000000"
109 Configuration_AI_Voltage 0.Minimum = "-5,000000"
112 Configuration_AI_Voltage 0.InputTerminalConfiguration = "Differential"
110 Configuration_AI_Voltage 0.InputTerminalConfiguration = "Differential"
113 Configuration_AI_Voltage 1.Maximum = "10,000000"
111 Configuration_AI_Voltage 1.Maximum = "1,000000"
114 Configuration_AI_Voltage 1.Minimum = "0,000000"
112 Configuration_AI_Voltage 1.Minimum = "-1,000000"
115 Configuration_AI_Voltage 1.InputTerminalConfiguration = "Differential"
113 Configuration_AI_Voltage 1.InputTerminalConfiguration = "Differential"
116 Configuration_AI_Thermocouple.<size(s)> = "15"
114 Configuration_AI_Thermocouple.<size(s)> = "8"
117 Configuration_AI_Thermocouple 0.Maximum = "250,000000"
115 Configuration_AI_Thermocouple 0.Maximum = "250,000000"
118 Configuration_AI_Thermocouple 0.Minimum = "0,000000"
116 Configuration_AI_Thermocouple 0.Minimum = "-200,000000"
119 Configuration_AI_Thermocouple 0.Type = "K"
117 Configuration_AI_Thermocouple 0.Type = "K"
120 Configuration_AI_Thermocouple 0.CJC_Source = "Built-In"
118 Configuration_AI_Thermocouple 0.CJC_Source = "Built-In"
121 Configuration_AI_Thermocouple 0.CJC_Value = "25,000000"
119 Configuration_AI_Thermocouple 0.CJC_Value = "25,000000"
122 Configuration_AI_Thermocouple 1.Maximum = "250,000000"
120 Configuration_AI_Thermocouple 1.Maximum = "250,000000"
123 Configuration_AI_Thermocouple 1.Minimum = "0,000000"
121 Configuration_AI_Thermocouple 1.Minimum = "-200,000000"
124 Configuration_AI_Thermocouple 1.Type = "K"
122 Configuration_AI_Thermocouple 1.Type = "K"
125 Configuration_AI_Thermocouple 1.CJC_Source = "Built-In"
123 Configuration_AI_Thermocouple 1.CJC_Source = "Built-In"
126 Configuration_AI_Thermocouple 1.CJC_Value = "25,000000"
124 Configuration_AI_Thermocouple 1.CJC_Value = "25,000000"
127 Configuration_AI_Thermocouple 2.Maximum = "250,000000"
125 Configuration_AI_Thermocouple 2.Maximum = "250,000000"
128 Configuration_AI_Thermocouple 2.Minimum = "0,000000"
126 Configuration_AI_Thermocouple 2.Minimum = "-200,000000"
129 Configuration_AI_Thermocouple 2.Type = "K"
127 Configuration_AI_Thermocouple 2.Type = "K"
130 Configuration_AI_Thermocouple 2.CJC_Source = "Built-In"
128 Configuration_AI_Thermocouple 2.CJC_Source = "Built-In"
131 Configuration_AI_Thermocouple 2.CJC_Value = "25,000000"
129 Configuration_AI_Thermocouple 2.CJC_Value = "25,000000"
132 Configuration_AI_Thermocouple 3.Maximum = "250,000000"
130 Configuration_AI_Thermocouple 3.Maximum = "250,000000"
133 Configuration_AI_Thermocouple 3.Minimum = "0,000000"
131 Configuration_AI_Thermocouple 3.Minimum = "-200,000000"
134 Configuration_AI_Thermocouple 3.Type = "K"
132 Configuration_AI_Thermocouple 3.Type = "K"
135 Configuration_AI_Thermocouple 3.CJC_Source = "Built-In"
133 Configuration_AI_Thermocouple 3.CJC_Source = "Built-In"
136 Configuration_AI_Thermocouple 3.CJC_Value = "10,000000"
134 Configuration_AI_Thermocouple 3.CJC_Value = "10,000000"
137 Configuration_AI_Thermocouple 4.Maximum = "250,000000"
135 Configuration_AI_Thermocouple 4.Maximum = "250,000000"
138 Configuration_AI_Thermocouple 4.Minimum = "0,000000"
136 Configuration_AI_Thermocouple 4.Minimum = "-200,000000"
139 Configuration_AI_Thermocouple 4.Type = "K"
137 Configuration_AI_Thermocouple 4.Type = "K"
140 Configuration_AI_Thermocouple 4.CJC_Source = "Built-In"
138 Configuration_AI_Thermocouple 4.CJC_Source = "Built-In"
141 Configuration_AI_Thermocouple 4.CJC_Value = "25,000000"
139 Configuration_AI_Thermocouple 4.CJC_Value = "25,000000"
142 Configuration_AI_Thermocouple 5.Maximum = "250,000000"
140 Configuration_AI_Thermocouple 5.Maximum = "250,000000"
143 Configuration_AI_Thermocouple 5.Minimum = "0,000000"
141 Configuration_AI_Thermocouple 5.Minimum = "-200,000000"
144 Configuration_AI_Thermocouple 5.Type = "K"
142 Configuration_AI_Thermocouple 5.Type = "K"
145 Configuration_AI_Thermocouple 5.CJC_Source = "Built-In"
143 Configuration_AI_Thermocouple 5.CJC_Source = "Built-In"
146 Configuration_AI_Thermocouple 5.CJC_Value = "25,000000"
144 Configuration_AI_Thermocouple 5.CJC_Value = "25,000000"
147 Configuration_AI_Thermocouple 6.Maximum = "250,000000"
145 Configuration_AI_Thermocouple 6.Maximum = "250,000000"
148 Configuration_AI_Thermocouple 6.Minimum = "0,000000"
146 Configuration_AI_Thermocouple 6.Minimum = "-200,000000"
149 Configuration_AI_Thermocouple 6.Type = "K"
147 Configuration_AI_Thermocouple 6.Type = "K"
150 Configuration_AI_Thermocouple 6.CJC_Source = "Built-In"
148 Configuration_AI_Thermocouple 6.CJC_Source = "Built-In"
151 Configuration_AI_Thermocouple 6.CJC_Value = "25,000000"
149 Configuration_AI_Thermocouple 6.CJC_Value = "25,000000"
152 Configuration_AI_Thermocouple 7.Maximum = "250,000000"
150 Configuration_AI_Thermocouple 7.Maximum = "250,000000"
153 Configuration_AI_Thermocouple 7.Minimum = "0,000000"
151 Configuration_AI_Thermocouple 7.Minimum = "-200,000000"
154 Configuration_AI_Thermocouple 7.Type = "K"
152 Configuration_AI_Thermocouple 7.Type = "K"
155 Configuration_AI_Thermocouple 7.CJC_Source = "Built-In"
153 Configuration_AI_Thermocouple 7.CJC_Source = "Built-In"
156 Configuration_AI_Thermocouple 7.CJC_Value = "25,000000"
154 Configuration_AI_Thermocouple 7.CJC_Value = "25,000000"
157 Configuration_AI_Thermocouple 8.Maximum = "250,000000"
155 Configuration_AI_NI9219_Resistance.<size(s)> = "4"
158 Configuration_AI_Thermocouple 8.Minimum = "0,000000"
156 Configuration_AI_NI9219_Resistance 0.Maximum = "10500,000000"
159 Configuration_AI_Thermocouple 8.Type = "K"
160 Configuration_AI_Thermocouple 8.CJC_Source = "Built-In"
161 Configuration_AI_Thermocouple 8.CJC_Value = "25,000000"
162 Configuration_AI_Thermocouple 9.Maximum = "250,000000"
163 Configuration_AI_Thermocouple 9.Minimum = "0,000000"
164 Configuration_AI_Thermocouple 9.Type = "K"
165 Configuration_AI_Thermocouple 9.CJC_Source = "Built-In"
166 Configuration_AI_Thermocouple 9.CJC_Value = "25,000000"
167 Configuration_AI_Thermocouple 10.Maximum = "250,000000"
168 Configuration_AI_Thermocouple 10.Minimum = "0,000000"
169 Configuration_AI_Thermocouple 10.Type = "K"
170 Configuration_AI_Thermocouple 10.CJC_Source = "Built-In"
171 Configuration_AI_Thermocouple 10.CJC_Value = "25,000000"
172 Configuration_AI_Thermocouple 11.Maximum = "250,000000"
173 Configuration_AI_Thermocouple 11.Minimum = "-200,000000"
174 Configuration_AI_Thermocouple 11.Type = "K"
175 Configuration_AI_Thermocouple 11.CJC_Source = "Built-In"
176 Configuration_AI_Thermocouple 11.CJC_Value = "25,000000"
177 Configuration_AI_Thermocouple 12.Maximum = "250,000000"
178 Configuration_AI_Thermocouple 12.Minimum = "-200,000000"
179 Configuration_AI_Thermocouple 12.Type = "K"
180 Configuration_AI_Thermocouple 12.CJC_Source = "Built-In"
181 Configuration_AI_Thermocouple 12.CJC_Value = "25,000000"
182 Configuration_AI_Thermocouple 13.Maximum = "250,000000"
183 Configuration_AI_Thermocouple 13.Minimum = "-200,000000"
184 Configuration_AI_Thermocouple 13.Type = "K"
185 Configuration_AI_Thermocouple 13.CJC_Source = "Built-In"
186 Configuration_AI_Thermocouple 13.CJC_Value = "10,000000"
187 Configuration_AI_Thermocouple 14.Maximum = "250,000000"
188 Configuration_AI_Thermocouple 14.Minimum = "-200,000000"
189 Configuration_AI_Thermocouple 14.Type = "K"
190 Configuration_AI_Thermocouple 14.CJC_Source = "Built-In"
191 Configuration_AI_Thermocouple 14.CJC_Value = "25,000000"
192 Configuration_AI_NI9219_Resistance.<size(s)> = "7"
193 Configuration_AI_NI9219_Resistance 0.Maximum = "800,000000"
194 Configuration_AI_NI9219_Resistance 0.Minimum = "0,000000"
157 Configuration_AI_NI9219_Resistance 0.Minimum = "0,000000"
195 Configuration_AI_NI9219_Resistance 0.Configuration = "4-Wire"
158 Configuration_AI_NI9219_Resistance 0.Configuration = "2-Wire"
196 Configuration_AI_NI9219_Resistance 0.CurrentExcitationSource = "Internal"
159 Configuration_AI_NI9219_Resistance 0.CurrentExcitationSource = "Internal"
197 Configuration_AI_NI9219_Resistance 0.CurrentExcitationValue = "0,000500"
160 Configuration_AI_NI9219_Resistance 0.CurrentExcitationValue = "0,000500"
198 Configuration_AI_NI9219_Resistance 0.RTD_Type = "Pt3750"
161 Configuration_AI_NI9219_Resistance 0.RTD_Type = "Pt3750"
199 Configuration_AI_NI9219_Resistance 0.R0 = "1000,000000"
162 Configuration_AI_NI9219_Resistance 0.R0 = "1000,000000"
200 Configuration_AI_NI9219_Resistance 0.ABC = "<size(s)=3> 1,224E-3 2,31E-4 3,938074E-9"
163 Configuration_AI_NI9219_Resistance 0.ABC = "<size(s)=3> 1,224312924E-3 2,308955523E-4 3,938074268E-9"
201 Configuration_AI_NI9219_Resistance 1.Maximum = "250,000000"
164 Configuration_AI_NI9219_Resistance 1.Maximum = "250,000000"
202 Configuration_AI_NI9219_Resistance 1.Minimum = "0,000000"
165 Configuration_AI_NI9219_Resistance 1.Minimum = "-200,000000"
203 Configuration_AI_NI9219_Resistance 1.Configuration = "2-Wire"
166 Configuration_AI_NI9219_Resistance 1.Configuration = "2-Wire"
204 Configuration_AI_NI9219_Resistance 1.CurrentExcitationSource = "Internal"
167 Configuration_AI_NI9219_Resistance 1.CurrentExcitationSource = "Internal"
205 Configuration_AI_NI9219_Resistance 1.CurrentExcitationValue = "0,000500"
168 Configuration_AI_NI9219_Resistance 1.CurrentExcitationValue = "0,000500"
206 Configuration_AI_NI9219_Resistance 1.RTD_Type = "Pt3750"
169 Configuration_AI_NI9219_Resistance 1.RTD_Type = "Pt3750"
207 Configuration_AI_NI9219_Resistance 1.R0 = "1000,000000"
170 Configuration_AI_NI9219_Resistance 1.R0 = "1000,000000"
208 Configuration_AI_NI9219_Resistance 1.ABC = "<size(s)=3> 1,224E-3 2,31E-4 3,938074E-9"
171 Configuration_AI_NI9219_Resistance 1.ABC = "<size(s)=3> 1,224312924E-3 2,308955523E-4 3,938074268E-9"
209 Configuration_AI_NI9219_Resistance 2.Maximum = "250,000000"
172 Configuration_AI_NI9219_Resistance 2.Maximum = "250,000000"
210 Configuration_AI_NI9219_Resistance 2.Minimum = "0,000000"
173 Configuration_AI_NI9219_Resistance 2.Minimum = "-200,000000"
211 Configuration_AI_NI9219_Resistance 2.Configuration = "2-Wire"
174 Configuration_AI_NI9219_Resistance 2.Configuration = "2-Wire"
212 Configuration_AI_NI9219_Resistance 2.CurrentExcitationSource = "Internal"
175 Configuration_AI_NI9219_Resistance 2.CurrentExcitationSource = "Internal"
213 Configuration_AI_NI9219_Resistance 2.CurrentExcitationValue = "0,000500"
176 Configuration_AI_NI9219_Resistance 2.CurrentExcitationValue = "0,000500"
214 Configuration_AI_NI9219_Resistance 2.RTD_Type = "Pt3750"
177 Configuration_AI_NI9219_Resistance 2.RTD_Type = "Pt3750"
215 Configuration_AI_NI9219_Resistance 2.R0 = "1000,000000"
178 Configuration_AI_NI9219_Resistance 2.R0 = "1000,000000"
216 Configuration_AI_NI9219_Resistance 2.ABC = "<size(s)=3> 3,81E-3 -6,02E-7 -6E-12"
179 Configuration_AI_NI9219_Resistance 2.ABC = "<size(s)=3> 1,224312924E-3 2,308955523E-4 3,938074268E-9"
217 Configuration_AI_NI9219_Resistance 3.Maximum = "250,000000"
180 Configuration_AI_NI9219_Resistance 3.Maximum = "250,000000"
218 Configuration_AI_NI9219_Resistance 3.Minimum = "0,000000"
181 Configuration_AI_NI9219_Resistance 3.Minimum = "-200,000000"
219 Configuration_AI_NI9219_Resistance 3.Configuration = "2-Wire"
182 Configuration_AI_NI9219_Resistance 3.Configuration = "2-Wire"
220 Configuration_AI_NI9219_Resistance 3.CurrentExcitationSource = "Internal"
183 Configuration_AI_NI9219_Resistance 3.CurrentExcitationSource = "Internal"
221 Configuration_AI_NI9219_Resistance 3.CurrentExcitationValue = "0,000500"
184 Configuration_AI_NI9219_Resistance 3.CurrentExcitationValue = "0,000500"
222 Configuration_AI_NI9219_Resistance 3.RTD_Type = "Pt3750"
185 Configuration_AI_NI9219_Resistance 3.RTD_Type = "Pt3750"
223 Configuration_AI_NI9219_Resistance 3.R0 = "1000,000000"
186 Configuration_AI_NI9219_Resistance 3.R0 = "1000,000000"
224 Configuration_AI_NI9219_Resistance 3.ABC = "<size(s)=3> 1,224312924E-3 2,308955523E-4 3,938074268E-9"
187 Configuration_AI_NI9219_Resistance 3.ABC = "<size(s)=3> 1,224312924E-3 2,308955523E-4 3,938074268E-9"
225 Configuration_AI_NI9219_Resistance 4.Maximum = "10500,000000"
188 Configuration_AI_NI9219_Type.<size(s)> = "4"
226 Configuration_AI_NI9219_Resistance 4.Minimum = "0,000000"
189 Configuration_AI_NI9219_Type 0 = "Thermocouple"
227 Configuration_AI_NI9219_Resistance 4.Configuration = "2-Wire"
190 Configuration_AI_NI9219_Type 1 = "Thermocouple"
228 Configuration_AI_NI9219_Resistance 4.CurrentExcitationSource = "Internal"
229 Configuration_AI_NI9219_Resistance 4.CurrentExcitationValue = "0,000500"
230 Configuration_AI_NI9219_Resistance 4.RTD_Type = "Pt3750"
231 Configuration_AI_NI9219_Resistance 4.R0 = "1000,000000"
232 Configuration_AI_NI9219_Resistance 4.ABC = "<size(s)=3> 0,001224 0,000231 3,938074E-9"
233 Configuration_AI_NI9219_Resistance 5.Maximum = "250,000000"
234 Configuration_AI_NI9219_Resistance 5.Minimum = "0,000000"
235 Configuration_AI_NI9219_Resistance 5.Configuration = "2-Wire"
236 Configuration_AI_NI9219_Resistance 5.CurrentExcitationSource = "Internal"
237 Configuration_AI_NI9219_Resistance 5.CurrentExcitationValue = "0,000500"
238 Configuration_AI_NI9219_Resistance 5.RTD_Type = "Pt3750"
239 Configuration_AI_NI9219_Resistance 5.R0 = "1000,000000"
240 Configuration_AI_NI9219_Resistance 5.ABC = "<size(s)=3> 0,001224 0,000231 3,938074E-9"
241 Configuration_AI_NI9219_Resistance 6.Maximum = "250,000000"
242 Configuration_AI_NI9219_Resistance 6.Minimum = "0,000000"
243 Configuration_AI_NI9219_Resistance 6.Configuration = "2-Wire"
244 Configuration_AI_NI9219_Resistance 6.CurrentExcitationSource = "Internal"
245 Configuration_AI_NI9219_Resistance 6.CurrentExcitationValue = "0,000500"
246 Configuration_AI_NI9219_Resistance 6.RTD_Type = "Pt3750"
247 Configuration_AI_NI9219_Resistance 6.R0 = "1000,000000"
248 Configuration_AI_NI9219_Resistance 6.ABC = "<size(s)=3> 0,003810 -6,020000E-7 -6,000000E-12"
249 Configuration_AI_NI9219_Type.<size(s)> = "7"
250 Configuration_AI_NI9219_Type 0 = "RTD"
251 Configuration_AI_NI9219_Type 1 = "Resistance_Thermistor"
252 Configuration_AI_NI9219_Type 2 = "Thermocouple"
191 Configuration_AI_NI9219_Type 2 = "Thermocouple"
253 Configuration_AI_NI9219_Type 3 = "Resistance_RTD"
192 Configuration_AI_NI9219_Type 3 = "Thermocouple"
254 Configuration_AI_NI9219_Type 4 = "Resistance_RTD"
255 Configuration_AI_NI9219_Type 5 = "Resistance_RTD"
256 Configuration_AI_NI9219_Type 6 = "Resistance_RTD"
257 POS_Config.IP = "10.1.2.1"
258 POS_Config.Port = "502"
259 POS_AxesNames.<size(s)> = "3"
260 POS_AxesNames 0 = "X"
261 POS_AxesNames 1 = "Y"
262 POS_AxesNames 2 = "Z"
263 POS_Reference_Axes = "<size(s)=3> 1,000000 1,000000 308,000000"
264 POS_Limits_Axis1 = "<size(s)=2> 0 155"
265 POS_Limits_Axis2 = "<size(s)=2> 0 303"
266 POS_Limits_Axis3 = "<size(s)=2> 0 309"
267 POS_AxesFlipped.<size(s)> = "3"
268 POS_AxesFlipped 0 = "True"
269 POS_AxesFlipped 1 = "True"
270 POS_AxesFlipped 2 = "False"
271 Pos_MaxVelocity = "300"
272 Pos_MaxAcceleration = "15000"
273 Pos_MaxJerk = "140000"
274 Pos_DO_E-Stop_Index = "0"
275 Pos_DO_Setup_Index = "2"
276 ForceLimit_Axis3 = "<size(s)=1> 0,000000"
277 ForceLimit_Axis3_Text.<size(s)> = "1"
278 ForceLimit_Axis3_Text 0 = ""
279 ForceLimit_Axis3_AO_Limits = "<size(s)=2> 0,000000 100,000000"
280 ForceLimit_AI_Index = "0"
281 AirCooling_AI_Index = "1"
282 AirCooling_AO_Index = "0"
283
193
284 [DefaultValues]
194 [DefaultValues]
285 WorkingStroke = "0"
195 WorkingStroke = "0"
286 MaxTemperature = "<size(s)=15> 50,000000 250,000000 250,000000 250,000000 250,000000 250,000000 250,000000 250,000000 250,000000 250,000000 250,000000 250,000000 250,000000 250,000000 250,000000"
196 MaxTemperature = "<size(s)=15> 50,000000 250,000000 250,000000 250,000000 250,000000 250,000000 250,000000 250,000000 250,000000 250,000000 250,000000 250,000000 250,000000 250,000000 250,000000"
287 MeasurementTime = "1"
197 MeasurementTime = "1"
288 NominalCurrent = "0"
198 NominalCurrent = "0"
289 TableControl = False
199 TableControl = False
290 SensorsColor = "<size(s)=15> 16776960 16711680 16744448 16744640 16711935 10879142 8388863 8421631 423327 9567230 14869218 14869218 14869218 14869218 14869218"
200 SensorsColor = "<size(s)=15> 16776960 16711680 16744448 16744640 16711935 10879142 8388863 8421631 423327 9567230 14869218 14869218 14869218 14869218 14869218"
291 Sensors+.<size(s)> = "15"
201 Sensors+.<size(s)> = "15"
292 Sensors+ 0 = "True"
202 Sensors+ 0 = "True"
293 Sensors+ 1 = "True"
203 Sensors+ 1 = "True"
294 Sensors+ 2 = "True"
204 Sensors+ 2 = "True"
295 Sensors+ 3 = "False"
205 Sensors+ 3 = "True"
296 Sensors+ 4 = "False"
206 Sensors+ 4 = "False"
297 Sensors+ 5 = "False"
207 Sensors+ 5 = "False"
298 Sensors+ 6 = "False"
208 Sensors+ 6 = "False"
299 Sensors+ 7 = "False"
209 Sensors+ 7 = "False"
300 Sensors+ 8 = "False"
210 Sensors+ 8 = "False"
301 Sensors+ 9 = "False"
211 Sensors+ 9 = "False"
302 Sensors+ 10 = "False"
212 Sensors+ 10 = "False"
303 Sensors+ 11 = "False"
213 Sensors+ 11 = "False"
304 Sensors+ 12 = "False"
214 Sensors+ 12 = "False"
305 Sensors+ 13 = "False"
215 Sensors+ 13 = "False"
306 Sensors+ 14 = "False"
216 Sensors+ 14 = "False"
307 SensorsFunction.<size(s)> = "15"
217 SensorsFunction.<size(s)> = "15"
308 SensorsFunction 0 = "Umgebungstemperatur"
218 SensorsFunction 0 = "Umgebungstemperatur"
309 SensorsFunction 1 = "Pr�flingstemperatur"
219 SensorsFunction 1 = "Pr�flingstemperatur"
310 SensorsFunction 2 = "Temperatur 3"
220 SensorsFunction 2 = "Temperatur 3"
311 SensorsFunction 3 = "Temperatur 4"
221 SensorsFunction 3 = "Temperatur 4"
312 SensorsFunction 4 = "Temperatur 5"
222 SensorsFunction 4 = "Temperatur 5"
313 SensorsFunction 5 = "Temperatur 6"
223 SensorsFunction 5 = "Temperatur 6"
314 SensorsFunction 6 = "Temperatur 7"
224 SensorsFunction 6 = "Temperatur 7"
315 SensorsFunction 7 = "Temperatur 8"
225 SensorsFunction 7 = "Temperatur 8"
316 SensorsFunction 8 = "Temperatur 9"
226 SensorsFunction 8 = "Temperatur 9"
317 SensorsFunction 9 = "Temperatur 10"
227 SensorsFunction 9 = "Temperatur 10"
318 SensorsFunction 10 = "Temperatur 11"
228 SensorsFunction 10 = "Temperatur 11"
319 SensorsFunction 11 = "Temperatur 12"
229 SensorsFunction 11 = "Temperatur 12"
320 SensorsFunction 12 = "Temperatur 13"
230 SensorsFunction 12 = "Temperatur 13"
321 SensorsFunction 13 = "Temperatur 14"
231 SensorsFunction 13 = "Temperatur 14"
322 SensorsFunction 14 = "Temperatur 15"
232 SensorsFunction 14 = "Temperatur 15"
323 ForceLimit_Z = "0"
233 ForceLimit_Z = "0"
324 MovingParameter.Velocity = "20,000000"
234 MovingParameter.Velocity = "20,000000"
325 MovingParameter.Acceleration = "50,000000"
235 MovingParameter.Acceleration = "50,000000"
326 MovingParameter.Jerk = "140000,000000"
236 MovingParameter.Jerk = "140000,000000"
327 Learning_Steps.X = "1,000000"
237 Learning_Steps.X = "1,000000"
328 Learning_Steps.Y = "1,000000"
238 Learning_Steps.Y = "1,000000"
329 Learning_Steps.Z = "1,000000"
239 Learning_Steps.Z = "1,000000"
330
240
331 [Pathes]
241 [Pathes]
332 User = "C:\Work\CurrentTester\support\User.txt"
242 User = "C:\Work\CurrentTester\support\User.txt"
333 ReportsFolder = "C:\Work\CurrentTester\support\ResultData_HSMP2"
243 ReportsFolder = "C:\Work\CurrentTester\support\ResultData_SMP3"
334 ProtocolsFolder = "\\orion\G K S - Test1\01_Access\Anlagen"
244 ProtocolsFolder = "\\orion\G K S - Test1\01_Access\Anlagen"
335 CurrentProfilesFolder = "\\orion\labview\CurrentTester\support\CurrentProfiles"
245 CurrentProfilesFolder = "\\orion\labview\CurrentTester\support\CurrentProfiles"
336 Applicants = "C:\Work\CurrentTester\support\Applicants.txt"
246 Applicants = "C:\Work\CurrentTester\support\Applicants.txt"
337 Note = "C:\Work\CurrentTester\support\Note.txt"
247 Note = "C:\Work\CurrentTester\support\Note.txt"
338
248
339 [Report]
249 [Report]
340 FileNameFormat = "%s_TestResults.txt"
250 FileNameFormat = "%s_TestResults.txt"
341 ReportNameFormat = "%s_TestReport_%s.xlsx"
251 ReportNameFormat = "%s_TestReport_%s.xlsx"
342 ReportTemplate_German = "C:\Work\CurrentTester\support\ReportTemplates\TemplateGerman.xlsx"
252 ReportTemplate_German = "C:\Work\CurrentTester\support\ReportTemplates\TemplateGerman.xlsx"
343 ReportTemplate_English = "C:\Work\CurrentTester\support\ReportTemplates\TemplateEnglish.xlsx"
253 ReportTemplate_English = "C:\Work\CurrentTester\support\ReportTemplates\TemplateEnglish.xlsx"
344
254
345 [Protocol]
255 [Protocol]
346 ProtocolNameFormat = "%s_A%d_Report_%s.docx"
256 ProtocolNameFormat = "%s_A%d_Report_%s.docx"
347 ProtocolTemplate_German = "C:\Work\CurrentTester\support\ReportTemplates\ProtocolTemplateGerman.dotx"
257 ProtocolTemplate_German = "C:\Work\CurrentTester\support\ReportTemplates\ProtocolTemplateGerman.dotx"
348 ProtocolTemplate_English = "C:\Work\CurrentTester\support\ReportTemplates\ProtocolTemplateEnglish.dotx"
258 ProtocolTemplate_English = "C:\Work\CurrentTester\support\ReportTemplates\ProtocolTemplateEnglish.dotx"
349 ProtocolComment_German = "Alle Messungen sind mit einem galvanisch isoliertem Thermosensor Type K durchf�hrt worden.\0ADie Testergebnisse und Auswertungen beziehen sich ausschlie�lich auf die Muster, die zu diesem Test unter Laborbedingungen verwendet wurden und auf den verwendeten Testaufbau!"
259 ProtocolComment_German = "Alle Messungen sind mit einem galvanisch isoliertem Thermosensor Type K durchf�hrt worden.\0ADie Testergebnisse und Auswertungen beziehen sich ausschlie�lich auf die Muster, die zu diesem Test unter Laborbedingungen verwendet wurden und auf den verwendeten Testaufbau!"
350 ProtocolComment_English = "All measurements were carried out with a galvanically isolated Type K thermal sensors.\0AThe test results and evaluations refer exclusively to the samples that were used for this test under laboratory conditions and to the test setup used!"
260 ProtocolComment_English = "All measurements were carried out with a galvanically isolated Type K thermal sensors.\0AThe test results and evaluations refer exclusively to the samples that were used for this test under laboratory conditions and to the test setup used!"
351 ProtocolDataFolderName = "Bilder|Messungen"
261 ProtocolDataFolderName = "Bilder|Messungen"
352 ProtocolFolderFormat = "%s_%s_Stromtest"
262 ProtocolFolderFormat = "%s_%s_Stromtest"
353
263
354 [StateMessages]
264 [StateMessages]
355 Info.<size(s)> = "32"
265 Info.<size(s)> = "26"
356 Info 0 = "Aktivierter Not-Halt oder eine T�r steht offen! Ein Teststart ist nicht m�glich"
266 Info 0 = "Aktivierter Not-Halt oder eine T�r steht offen! Ein Teststart ist nicht m�glich"
357 Info 1 = "Zum Anlegen eines neuen Tests "Neuer Test" klicken"
267 Info 1 = "Zum Anlegen eines neuen Tests "Neuer Test" klicken"
358 Info 2 = "Grunddaten anlegen oder bestehenden Test �ffnen"
268 Info 2 = "Grunddaten anlegen oder bestehenden Test �ffnen"
359 Info 3 = "Testdaten anlegen"
269 Info 3 = "Testdaten anlegen"
360 Info 4 = "Zur manuellen Stromeinstellung sollte die Schutzt�renfreigabe aufgehoben werden, zum Verfahren der Achsen sollte der Automatikbetrieb der Anlagensteuerung aktiviert werden!"
270 Info 4 = "Der Schl�sselschalter muss in die Position "Einrichten" gebracht werden um die Einrichtbuttons zu aktivieren oder in die Position "Automatik" um den Test starten zu k�nnen oder den Strom manuell einzustellen!"
361 Info 5 = "Test geladen"
271 Info 5 = "Test geladen"
362 Info 6 = "Laufende Pr�fung..."
272 Info 6 = "Laufende Pr�fung..."
363 Info 7 = "Pr�fung erfolgreich abgeschlossen"
273 Info 7 = "Pr�fung erfolgreich abgeschlossen"
364 Info 8 = "Fehler aufgetreten!"
274 Info 8 = "Fehler aufgetreten!"
365 Info 9 = "Test abgebrochen!"
275 Info 9 = "Test abgebrochen!"
366 Info 10 = "Test abgebrochen! Maximale Temperatur wurde �berschritten"
276 Info 10 = "Test abgebrochen! Maximale Temperatur wurde �berschritten"
367 Info 11 = "Test abgebrochen! Fehlerhafte Kontaktierung"
277 Info 11 = "Test abgebrochen! Fehlerhafte Kontaktierung"
368 Info 12 = "Test abgebrochen! Messrate ist zu hoch"
278 Info 12 = "Test abgebrochen! Messrate ist zu hoch"
369 Info 13 = "Test abgebrochen! Stromprofil- Generierung ist fehlgeschlagen"
279 Info 13 = "Test abgebrochen! Stromprofil- Generierung ist fehlgeschlagen"
370 Info 14 = "Test abgebrochen! Eingestellte Abschaltleistung der Stromquelle wurde erreicht"
280 Info 14 = "Test abgebrochen! Eingestellte Abschaltleistung der Stromquelle wurde erreicht"
371 Info 15 = "Test abgebrochen! Gemessener Strom liegt au�erhalb des definierten Bereichs"
281 Info 15 = "Test abgebrochen! Gemessener Strom liegt au�erhalb des definierten Bereichs"
372 Info 16 = "Testprotokoll wird erstellt... Bitte warten"
282 Info 16 = "Testprotokoll wird erstellt... Bitte warten"
373 Info 17 = "Testprotokoll erstellt"
283 Info 17 = "Testprotokoll erstellt"
374 Info 18 = "Der letzte Test ist geladen..."
284 Info 18 = "Der letzte Test ist geladen..."
375 Info 19 = "Testdaten zur Testberichterstellung laden"
285 Info 19 = "Testdaten zur Testberichterstellung laden"
376 Info 20 = "Testdaten werden geladen... Bitte warten"
286 Info 20 = "Testdaten werden geladen... Bitte warten"
377 Info 21 = "Testdaten zur Testberichterstellung ausw�hlen"
287 Info 21 = "Testdaten zur Testberichterstellung ausw�hlen"
378 Info 22 = "Testbericht wird erstellt... Bitte warten"
288 Info 22 = "Testbericht wird erstellt... Bitte warten"
379 Info 23 = "Testbericht erstellt"
289 Info 23 = "Testbericht erstellt"
380 Info 24 = "Test ist gespeichert"
290 Info 24 = "Test ist gespeichert"
381 Info 25 = "Testdaten werden ge�ndert... Bitte warten"
291 Info 25 = "Testdaten werden ge�ndert... Bitte warten"
382 Info 26 = "Achsen werden initialisiert..."
292 Result.<size(s)> = "26"
383 Info 27 = "Referenzfahrt l�uft..."
384 Info 28 = "X-Achse wird referenziert..."
385 Info 29 = "Y-Achse wird referenziert..."
386 Info 30 = "Z-Achse wird referenziert..."
387 Info 31 = "Position wird angefahren..."
388 Result.<size(s)> = "32"
389 Result 0 = "Not-Halt"
293 Result 0 = "Not-Halt"
390 Result 1 = ""
294 Result 1 = ""
391 Result 2 = "Bereit"
295 Result 2 = "Bereit"
392 Result 3 = "Bereit"
296 Result 3 = "Bereit"
393 Result 4 = "Einrichtbetrieb"
297 Result 4 = "Einrichtbetrieb"
394 Result 5 = "Bereit"
298 Result 5 = "Bereit"
395 Result 6 = "Pr�fung l�uft"
299 Result 6 = "Pr�fung l�uft"
396 Result 7 = "Pr�fung fertig"
300 Result 7 = "Pr�fung fertig"
397 Result 8 = "Fehler"
301 Result 8 = "Fehler"
398 Result 9 = "Pr�fung Stop"
302 Result 9 = "Pr�fung Stop"
399 Result 10 = "Pr�fung Stop"
303 Result 10 = "Pr�fung Stop"
400 Result 11 = "Pr�fung Stop"
304 Result 11 = "Pr�fung Stop"
401 Result 12 = "Pr�fung Stop"
305 Result 12 = "Pr�fung Stop"
402 Result 13 = "Pr�fung Stop"
306 Result 13 = "Pr�fung Stop"
403 Result 14 = "Pr�fung Stop"
307 Result 14 = "Pr�fung Stop"
404 Result 15 = "Pr�fung Stop"
308 Result 15 = "Pr�fung Stop"
405 Result 16 = "Bereit"
309 Result 16 = "Bereit"
406 Result 17 = "Bereit"
310 Result 17 = "Bereit"
407 Result 18 = "Bereit"
311 Result 18 = "Bereit"
408 Result 19 = "Bereit"
312 Result 19 = "Bereit"
409 Result 20 = "Bereit"
313 Result 20 = "Bereit"
410 Result 21 = "Bereit"
314 Result 21 = "Bereit"
411 Result 22 = "Bereit"
315 Result 22 = "Bereit"
412 Result 23 = "Bereit"
316 Result 23 = "Bereit"
413 Result 24 = "Bereit"
317 Result 24 = "Bereit"
414 Result 25 = "Bereit"
318 Result 25 = "Bereit"
415 Result 26 = ""
416 Result 27 = "Einrichtbetrieb"
417 Result 28 = "Einrichtbetrieb"
418 Result 29 = "Einrichtbetrieb"
419 Result 30 = "Einrichtbetrieb"
420 Result 31 = "Einrichtbetrieb"
421
319
422 [DialogMessages]
320 [DialogMessages]
423 Messages.<size(s)> = "13"
321 Messages.<size(s)> = "13"
424 Messages 0 = "Achtung Einrichtbetrieb!\0AM�gliche Gefahren:\0A-Klemmgefahr\0A-Hei�e Oberfl�chen\0A-Lichtbogen"
322 Messages 0 = "Achtung Einrichtbetrieb!\0AM�gliche Gefahren:\0A-Klemmgefahr\0A-Hei�e Oberfl�chen\0A-Lichtbogen"
425 Messages 1 = "Bitte achten Sie darauf, dass alle Eingabefelder in der gew�hlten Sprache sind"
323 Messages 1 = "Bitte achten Sie darauf, dass alle Eingabefelder in der gew�hlten Sprache sind"
426 Messages 2 = "Geben Sie die f�r die Testberichterstellung erforderlichen Daten ein. Bitte achten Sie darauf, dass alle Eingabefelder in der gew�hlten Sprache sind"
324 Messages 2 = "Geben Sie die f�r die Testberichterstellung erforderlichen Daten ein. Bitte achten Sie darauf, dass alle Eingabefelder in der gew�hlten Sprache sind"
427 Messages 3 = "\0A\0A\0AF�r den ausgew�hlten Artikel sind mehrere Stromprofile verf�gbar, eine kombinierte Anzeige ist daher nicht m�glich!"
325 Messages 3 = "\0A\0A\0AF�r den ausgew�hlten Artikel sind mehrere Stromprofile verf�gbar, eine kombinierte Anzeige ist daher nicht m�glich!"
428 Messages 4 = "W�hlen Sie eine Testkonfigurationsdatei zum Laden aus"
326 Messages 4 = "W�hlen Sie eine Testkonfigurationsdatei zum Laden aus"
429 Messages 5 = "W�hlen Sie einen Ordner aus, der die Testergebnisse zum Laden enth�lt"
327 Messages 5 = "W�hlen Sie einen Ordner aus, der die Testergebnisse zum Laden enth�lt"
430 Messages 6 = "W�hlen Sie einen ID-Ordner aus, der alle Testergebnisse zum Laden enth�lt"
328 Messages 6 = "W�hlen Sie einen ID-Ordner aus, der alle Testergebnisse zum Laden enth�lt"
431 Messages 7 = "Die Merkzetteldaten werden gel�scht!\0ABitte best�tigen Sie die Operation oder schlie�en Sie das Dialogfeld, um den Vorgang abzubrechen ..."
329 Messages 7 = "Die Merkzetteldaten werden gel�scht!\0ABitte best�tigen Sie die Operation oder schlie�en Sie das Dialogfeld, um den Vorgang abzubrechen ..."
432 Messages 8 = "Sollen die Testmessdaten zur sp�teren Testberichtserstellung au�erhalb des Stromtesters in das unten stehende Verzeichnis im Netzwerk kopiert werden?"
330 Messages 8 = "Sollen die Testmessdaten zur sp�teren Testberichtserstellung au�erhalb des Stromtesters in das unten stehende Verzeichnis im Netzwerk kopiert werden?"
433 Messages 9 = "Sollen die Testdaten ge�ndert, bestehende Verzeichnisse umbenannt und vorhandene Excel- Testprotokolle �berschrieben werden?"
331 Messages 9 = "Sollen die Testdaten ge�ndert, bestehende Verzeichnisse umbenannt und vorhandene Excel- Testprotokolle �berschrieben werden?"
434 Messages 10 = "W�hlen Sie Artikel zum Laden aus"
332 Messages 10 = "W�hlen Sie Artikel zum Laden aus"
435 Messages 11 = "Soll das unten stehende Verzeichnis erstellt werden?"
333 Messages 11 = "Soll das unten stehende Verzeichnis erstellt werden?"
436 Messages 12 = "Zur Achsensteuerung mit freigegebenen T�ren sollte der Zustimmtaster w�hrend der Bewegung gedr�ckt werden"
334 Messages 12 = "Zur Achsensteuerung mit freigegebenen T�ren sollte der Zustimmtaster w�hrend der Bewegung gedr�ckt werden"
437
335
438 [Tips]
336 [Tips]
439 Text.<size(s)> = "2"
337 Text.<size(s)> = "2"
440 Text 0 = "Der resultierende vollst�ndige Windows-Dateipfad f�r die eingegebene Test ID, den Unterordner und die Pr�flingsbezeichnung ist zu lang!"
338 Text 0 = "Der resultierende vollst�ndige Windows-Dateipfad f�r die eingegebene Test ID, den Unterordner und die Pr�flingsbezeichnung ist zu lang!"
441 Text 1 = "Der eingegebene Sensorname soll einmalig und nicht leer sein, maximal 31 Zeichen aufweisen und keines der folgenden Zeichen enthalten: \/:*?"<>|." No newline at end of file
339 Text 1 = "Der eingegebene Sensorname soll einmalig und nicht leer sein, maximal 31 Zeichen aufweisen und keines der folgenden Zeichen enthalten: \/:*?"<>|."
1 NO CONTENT: modified file
NO CONTENT: modified file
1 NO CONTENT: modified file
NO CONTENT: modified file
1 NO CONTENT: modified file
NO CONTENT: modified file
1 NO CONTENT: modified file
NO CONTENT: modified file
The requested commit or file is too big and content was truncated. Show full diff
1 NO CONTENT: modified file
NO CONTENT: modified file
General Comments 0
You need to be logged in to leave comments. Login now