- HSMP1 implemented (EXE updated)
LabVIEW -
r4:5
parent child Browse files
Show More
1 NO CONTENT: modified file
1 NO CONTENT: modified file
@@ -58,7 +58,7
58 58 ShuntResistance = 0,001
59 59 Measurement_Check = False
60 60 DMM_VISAName = "PXI1Slot3"
61 DMM_ContactLimits = "<size(s)=2> 0,0 1,5"
61 DMM_ContactLimits = "<size(s)=2> 0,0 1,0"
62 62 TemperatureGain = "<size(s)=10> 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000"
63 63 TemperatureOffset = "<size(s)=10> 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000"
64 64 VoltageGain = "<size(s)=4> 1,000000 1,000000 1,000000 1,000000"
@@ -84,61 +84,61
84 84 Configuration_AI_Voltage 1.InputTerminalConfiguration = "Differential"
85 85 Configuration_AI_Thermocouple.<size(s)> = "10"
86 86 Configuration_AI_Thermocouple 0.Maximum = "250,000000"
87 Configuration_AI_Thermocouple 0.Minimum = "-250,000000"
87 Configuration_AI_Thermocouple 0.Minimum = "-200,000000"
88 88 Configuration_AI_Thermocouple 0.Type = "K"
89 89 Configuration_AI_Thermocouple 0.CJC_Source = "Built-In"
90 90 Configuration_AI_Thermocouple 0.CJC_Value = "25,000000"
91 91 Configuration_AI_Thermocouple 0.Unit = "Deg C"
92 92 Configuration_AI_Thermocouple 1.Maximum = "250,000000"
93 Configuration_AI_Thermocouple 1.Minimum = "-250,000000"
93 Configuration_AI_Thermocouple 1.Minimum = "-200,000000"
94 94 Configuration_AI_Thermocouple 1.Type = "K"
95 95 Configuration_AI_Thermocouple 1.CJC_Source = "Built-In"
96 96 Configuration_AI_Thermocouple 1.CJC_Value = "25,000000"
97 97 Configuration_AI_Thermocouple 1.Unit = "Deg C"
98 98 Configuration_AI_Thermocouple 2.Maximum = "250,000000"
99 Configuration_AI_Thermocouple 2.Minimum = "-250,000000"
99 Configuration_AI_Thermocouple 2.Minimum = "-200,000000"
100 100 Configuration_AI_Thermocouple 2.Type = "K"
101 101 Configuration_AI_Thermocouple 2.CJC_Source = "Built-In"
102 102 Configuration_AI_Thermocouple 2.CJC_Value = "25,000000"
103 103 Configuration_AI_Thermocouple 2.Unit = "Deg C"
104 104 Configuration_AI_Thermocouple 3.Maximum = "250,000000"
105 Configuration_AI_Thermocouple 3.Minimum = "-250,000000"
105 Configuration_AI_Thermocouple 3.Minimum = "-200,000000"
106 106 Configuration_AI_Thermocouple 3.Type = "K"
107 107 Configuration_AI_Thermocouple 3.CJC_Source = "Constant Value"
108 108 Configuration_AI_Thermocouple 3.CJC_Value = "10,000000"
109 109 Configuration_AI_Thermocouple 3.Unit = "Deg C"
110 110 Configuration_AI_Thermocouple 4.Maximum = "250,000000"
111 Configuration_AI_Thermocouple 4.Minimum = "-250,000000"
111 Configuration_AI_Thermocouple 4.Minimum = "-200,000000"
112 112 Configuration_AI_Thermocouple 4.Type = "K"
113 113 Configuration_AI_Thermocouple 4.CJC_Source = "Built-In"
114 114 Configuration_AI_Thermocouple 4.CJC_Value = "25,000000"
115 115 Configuration_AI_Thermocouple 4.Unit = "Deg C"
116 116 Configuration_AI_Thermocouple 5.Maximum = "250,000000"
117 Configuration_AI_Thermocouple 5.Minimum = "-250,000000"
117 Configuration_AI_Thermocouple 5.Minimum = "-200,000000"
118 118 Configuration_AI_Thermocouple 5.Type = "K"
119 119 Configuration_AI_Thermocouple 5.CJC_Source = "Built-In"
120 120 Configuration_AI_Thermocouple 5.CJC_Value = "25,000000"
121 121 Configuration_AI_Thermocouple 5.Unit = "Deg C"
122 122 Configuration_AI_Thermocouple 6.Maximum = "250,000000"
123 Configuration_AI_Thermocouple 6.Minimum = "-250,000000"
123 Configuration_AI_Thermocouple 6.Minimum = "-200,000000"
124 124 Configuration_AI_Thermocouple 6.Type = "K"
125 125 Configuration_AI_Thermocouple 6.CJC_Source = "Built-In"
126 126 Configuration_AI_Thermocouple 6.CJC_Value = "25,000000"
127 127 Configuration_AI_Thermocouple 6.Unit = "Deg C"
128 128 Configuration_AI_Thermocouple 7.Maximum = "250,000000"
129 Configuration_AI_Thermocouple 7.Minimum = "-250,000000"
129 Configuration_AI_Thermocouple 7.Minimum = "-200,000000"
130 130 Configuration_AI_Thermocouple 7.Type = "K"
131 131 Configuration_AI_Thermocouple 7.CJC_Source = "Built-In"
132 132 Configuration_AI_Thermocouple 7.CJC_Value = "25,000000"
133 133 Configuration_AI_Thermocouple 7.Unit = "Deg C"
134 134 Configuration_AI_Thermocouple 8.Maximum = "250,000000"
135 Configuration_AI_Thermocouple 8.Minimum = "-250,000000"
135 Configuration_AI_Thermocouple 8.Minimum = "-200,000000"
136 136 Configuration_AI_Thermocouple 8.Type = "K"
137 137 Configuration_AI_Thermocouple 8.CJC_Source = "Built-In"
138 138 Configuration_AI_Thermocouple 8.CJC_Value = "25,000000"
139 139 Configuration_AI_Thermocouple 8.Unit = "Deg C"
140 140 Configuration_AI_Thermocouple 9.Maximum = "250,000000"
141 Configuration_AI_Thermocouple 9.Minimum = "-250,000000"
141 Configuration_AI_Thermocouple 9.Minimum = "-200,000000"
142 142 Configuration_AI_Thermocouple 9.Type = "K"
143 143 Configuration_AI_Thermocouple 9.CJC_Source = "Built-In"
144 144 Configuration_AI_Thermocouple 9.CJC_Value = "25,000000"
@@ -174,11 +174,44
174 174 PowerSupply_VISAName = "COM2"
175 175 PowerSupply_Address = "6"
176 176 PowerSupply_Baudrate = "9600"
177 PowerSupply_OutputVoltage = "8,000000"
178 PowerSupply_OverVoltageProtection = "9,000000"
177 179 DMM_Baudrate = "9600"
178 NI_USB6252_Out_LiftTable = "Dev1/port0/line5"
179 NI_USB6252_Out_SettingMode.<size(s)> = "2"
180 NI_USB6252_Out_SettingMode 0 = "Dev1/port0/line0"
181 NI_USB6252_Out_SettingMode 1 = "Dev1/port0/line1"
180 Measurement_Channels_AutoRange.<size(s)> = "13"
181 Measurement_Channels_AutoRange 0 = "TRUE"
182 Measurement_Channels_AutoRange 1 = "TRUE"
183 Measurement_Channels_AutoRange 2 = "TRUE"
184 Measurement_Channels_AutoRange 3 = "TRUE"
185 Measurement_Channels_AutoRange 4 = "TRUE"
186 Measurement_Channels_AutoRange 5 = "TRUE"
187 Measurement_Channels_AutoRange 6 = "TRUE"
188 Measurement_Channels_AutoRange 7 = "TRUE"
189 Measurement_Channels_AutoRange 8 = "TRUE"
190 Measurement_Channels_AutoRange 9 = "TRUE"
191 Measurement_Channels_AutoRange 10 = "TRUE"
192 Measurement_Channels_AutoRange 11 = "TRUE"
193 Measurement_Channels_AutoRange 12 = "TRUE"
194 Measurement_Channels_Range = "<size(s)=13> 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000"
195 Measurement_Channels_Resolution.<size(s)> = "13"
196 Measurement_Channels_Resolution 0 = "6.5"
197 Measurement_Channels_Resolution 1 = "6.5"
198 Measurement_Channels_Resolution 2 = "6.5"
199 Measurement_Channels_Resolution 3 = "6.5"
200 Measurement_Channels_Resolution 4 = "6.5"
201 Measurement_Channels_Resolution 5 = "6.5"
202 Measurement_Channels_Resolution 6 = "6.5"
203 Measurement_Channels_Resolution 7 = "6.5"
204 Measurement_Channels_Resolution 8 = "6.5"
205 Measurement_Channels_Resolution 9 = "6.5"
206 Measurement_Channels_Resolution 10 = "6.5"
207 Measurement_Channels_Resolution 11 = "6.5"
208 Measurement_Channels_Resolution 12 = "6.5"
209 Resistance_Function = "Resistance"
210 Resistance_OffsetCompensation = "FALSE"
211 TableControl_Out_LiftTable = "Dev1/port0/line5"
212 TableControl_Out_SettingMode.<size(s)> = "2"
213 TableControl_Out_SettingMode 0 = "Dev1/port0/line0"
214 TableControl_Out_SettingMode 1 = "Dev1/port0/line1"
182 215
183 216 [DefaultValues]
184 217 WorkingStroke = "0"
@@ -42,25 +42,26
42 42 DI_Setup = ""
43 43 PowerSupply_MinCurrent = "1"
44 44 PowerSupply_Check = False
45 Measurement_Channels.<size(s)> = "12"
45 Measurement_Channels.<size(s)> = "13"
46 46 Measurement_Channels 0 = "102"
47 Measurement_Channels 1 = "104"
48 Measurement_Channels 2 = "106"
49 Measurement_Channels 3 = "107"
50 Measurement_Channels 4 = "108"
51 Measurement_Channels 5 = "109"
52 Measurement_Channels 6 = "110"
53 Measurement_Channels 7 = ""
47 Measurement_Channels 1 = "102"
48 Measurement_Channels 2 = "104"
49 Measurement_Channels 3 = "106"
50 Measurement_Channels 4 = "107"
51 Measurement_Channels 5 = "108"
52 Measurement_Channels 6 = "109"
53 Measurement_Channels 7 = "110"
54 54 Measurement_Channels 8 = ""
55 55 Measurement_Channels 9 = ""
56 56 Measurement_Channels 10 = ""
57 57 Measurement_Channels 11 = ""
58 Measurement_Channels 12 = ""
58 59 ShuntResistance = 0,00006
59 60 Measurement_Check = False
60 61 DMM_VISAName = "COM1"
61 DMM_ContactLimits = "<size(s)=2> 0,0 50,0"
62 DMM_ContactLimits = "<size(s)=2> 0,0 0,05"
62 63 TemperatureGain = "<size(s)=10> 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000"
63 TemperatureOffset = "<size(s)=10> 0,000000 0,000000 0,000000 0,500000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000"
64 TemperatureOffset = "<size(s)=10> 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000"
64 65 VoltageGain = "<size(s)=4> 1,000000 1,000000 1,000000 1,000000"
65 66 VoltageOffset = "<size(s)=4> 0,000000 0,000000 0,000000 0,000000"
66 67 AllowedContactFails = "2"
@@ -84,61 +85,61
84 85 Configuration_AI_Voltage 1.InputTerminalConfiguration = "Differential"
85 86 Configuration_AI_Thermocouple.<size(s)> = "10"
86 87 Configuration_AI_Thermocouple 0.Maximum = "250,000000"
87 Configuration_AI_Thermocouple 0.Minimum = "-250,000000"
88 Configuration_AI_Thermocouple 0.Minimum = "-200,000000"
88 89 Configuration_AI_Thermocouple 0.Type = "K"
89 90 Configuration_AI_Thermocouple 0.CJC_Source = "Built-In"
90 91 Configuration_AI_Thermocouple 0.CJC_Value = "25,000000"
91 92 Configuration_AI_Thermocouple 0.Unit = "Deg C"
92 93 Configuration_AI_Thermocouple 1.Maximum = "250,000000"
93 Configuration_AI_Thermocouple 1.Minimum = "-250,000000"
94 Configuration_AI_Thermocouple 1.Minimum = "-200,000000"
94 95 Configuration_AI_Thermocouple 1.Type = "K"
95 96 Configuration_AI_Thermocouple 1.CJC_Source = "Built-In"
96 97 Configuration_AI_Thermocouple 1.CJC_Value = "25,000000"
97 98 Configuration_AI_Thermocouple 1.Unit = "Deg C"
98 99 Configuration_AI_Thermocouple 2.Maximum = "250,000000"
99 Configuration_AI_Thermocouple 2.Minimum = "-250,000000"
100 Configuration_AI_Thermocouple 2.Minimum = "-200,000000"
100 101 Configuration_AI_Thermocouple 2.Type = "K"
101 102 Configuration_AI_Thermocouple 2.CJC_Source = "Built-In"
102 103 Configuration_AI_Thermocouple 2.CJC_Value = "25,000000"
103 104 Configuration_AI_Thermocouple 2.Unit = "Deg C"
104 105 Configuration_AI_Thermocouple 3.Maximum = "250,000000"
105 Configuration_AI_Thermocouple 3.Minimum = "-250,000000"
106 Configuration_AI_Thermocouple 3.Minimum = "-200,000000"
106 107 Configuration_AI_Thermocouple 3.Type = "K"
107 108 Configuration_AI_Thermocouple 3.CJC_Source = "Constant Value"
108 109 Configuration_AI_Thermocouple 3.CJC_Value = "10,000000"
109 110 Configuration_AI_Thermocouple 3.Unit = "Deg C"
110 111 Configuration_AI_Thermocouple 4.Maximum = "250,000000"
111 Configuration_AI_Thermocouple 4.Minimum = "-250,000000"
112 Configuration_AI_Thermocouple 4.Minimum = "-200,000000"
112 113 Configuration_AI_Thermocouple 4.Type = "K"
113 114 Configuration_AI_Thermocouple 4.CJC_Source = "Built-In"
114 115 Configuration_AI_Thermocouple 4.CJC_Value = "25,000000"
115 116 Configuration_AI_Thermocouple 4.Unit = "Deg C"
116 117 Configuration_AI_Thermocouple 5.Maximum = "250,000000"
117 Configuration_AI_Thermocouple 5.Minimum = "-250,000000"
118 Configuration_AI_Thermocouple 5.Minimum = "-200,000000"
118 119 Configuration_AI_Thermocouple 5.Type = "K"
119 120 Configuration_AI_Thermocouple 5.CJC_Source = "Built-In"
120 121 Configuration_AI_Thermocouple 5.CJC_Value = "25,000000"
121 122 Configuration_AI_Thermocouple 5.Unit = "Deg C"
122 123 Configuration_AI_Thermocouple 6.Maximum = "250,000000"
123 Configuration_AI_Thermocouple 6.Minimum = "-250,000000"
124 Configuration_AI_Thermocouple 6.Minimum = "-200,000000"
124 125 Configuration_AI_Thermocouple 6.Type = "K"
125 126 Configuration_AI_Thermocouple 6.CJC_Source = "Built-In"
126 127 Configuration_AI_Thermocouple 6.CJC_Value = "25,000000"
127 128 Configuration_AI_Thermocouple 6.Unit = "Deg C"
128 129 Configuration_AI_Thermocouple 7.Maximum = "250,000000"
129 Configuration_AI_Thermocouple 7.Minimum = "-250,000000"
130 Configuration_AI_Thermocouple 7.Minimum = "-200,000000"
130 131 Configuration_AI_Thermocouple 7.Type = "K"
131 132 Configuration_AI_Thermocouple 7.CJC_Source = "Built-In"
132 133 Configuration_AI_Thermocouple 7.CJC_Value = "25,000000"
133 134 Configuration_AI_Thermocouple 7.Unit = "Deg C"
134 135 Configuration_AI_Thermocouple 8.Maximum = "250,000000"
135 Configuration_AI_Thermocouple 8.Minimum = "-250,000000"
136 Configuration_AI_Thermocouple 8.Minimum = "-200,000000"
136 137 Configuration_AI_Thermocouple 8.Type = "K"
137 138 Configuration_AI_Thermocouple 8.CJC_Source = "Built-In"
138 139 Configuration_AI_Thermocouple 8.CJC_Value = "25,000000"
139 140 Configuration_AI_Thermocouple 8.Unit = "Deg C"
140 141 Configuration_AI_Thermocouple 9.Maximum = "250,000000"
141 Configuration_AI_Thermocouple 9.Minimum = "-250,000000"
142 Configuration_AI_Thermocouple 9.Minimum = "-200,000000"
142 143 Configuration_AI_Thermocouple 9.Type = "K"
143 144 Configuration_AI_Thermocouple 9.CJC_Source = "Built-In"
144 145 Configuration_AI_Thermocouple 9.CJC_Value = "25,000000"
@@ -174,11 +175,44
174 175 PowerSupply_VISAName = "COM2"
175 176 PowerSupply_Address = "6"
176 177 PowerSupply_Baudrate = "9600"
178 PowerSupply_OutputVoltage = "8,000000"
179 PowerSupply_OverVoltageProtection = "9,000000"
177 180 DMM_Baudrate = "9600"
178 NI_USB6252_Out_LiftTable = "Dev1/port0/line5"
179 NI_USB6252_Out_SettingMode.<size(s)> = "2"
180 NI_USB6252_Out_SettingMode 0 = "Dev1/port0/line0"
181 NI_USB6252_Out_SettingMode 1 = "Dev1/port0/line1"
181 Measurement_Channels_AutoRange.<size(s)> = "13"
182 Measurement_Channels_AutoRange 0 = "TRUE"
183 Measurement_Channels_AutoRange 1 = "TRUE"
184 Measurement_Channels_AutoRange 2 = "TRUE"
185 Measurement_Channels_AutoRange 3 = "TRUE"
186 Measurement_Channels_AutoRange 4 = "TRUE"
187 Measurement_Channels_AutoRange 5 = "TRUE"
188 Measurement_Channels_AutoRange 6 = "TRUE"
189 Measurement_Channels_AutoRange 7 = "TRUE"
190 Measurement_Channels_AutoRange 8 = "TRUE"
191 Measurement_Channels_AutoRange 9 = "TRUE"
192 Measurement_Channels_AutoRange 10 = "TRUE"
193 Measurement_Channels_AutoRange 11 = "TRUE"
194 Measurement_Channels_AutoRange 12 = "TRUE"
195 Measurement_Channels_Range = "<size(s)=13> 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000"
196 Measurement_Channels_Resolution.<size(s)> = "13"
197 Measurement_Channels_Resolution 0 = "6.5"
198 Measurement_Channels_Resolution 1 = "6.5"
199 Measurement_Channels_Resolution 2 = "6.5"
200 Measurement_Channels_Resolution 3 = "6.5"
201 Measurement_Channels_Resolution 4 = "6.5"
202 Measurement_Channels_Resolution 5 = "6.5"
203 Measurement_Channels_Resolution 6 = "6.5"
204 Measurement_Channels_Resolution 7 = "6.5"
205 Measurement_Channels_Resolution 8 = "6.5"
206 Measurement_Channels_Resolution 9 = "6.5"
207 Measurement_Channels_Resolution 10 = "6.5"
208 Measurement_Channels_Resolution 11 = "6.5"
209 Measurement_Channels_Resolution 12 = "6.5"
210 Resistance_Function = "Resistance"
211 Resistance_OffsetCompensation = "FALSE"
212 TableControl_Out_LiftTable = "Dev1/port0/line5"
213 TableControl_Out_SettingMode.<size(s)> = "2"
214 TableControl_Out_SettingMode 0 = "Dev1/port0/line0"
215 TableControl_Out_SettingMode 1 = "Dev1/port0/line1"
182 216
183 217 [DefaultValues]
184 218 WorkingStroke = "0"
@@ -212,7 +246,7
212 246
213 247 [Pathes]
214 248 User = "C:\Work\CurrentTester\support\User.txt"
215 ReportsFolder = "C:\Work\CurrentTester\support\ResultData"
249 ReportsFolder = "C:\ResultData"
216 250 CurrentProfilesFolder = "C:\Work\CurrentTester\support\CurrentProfiles"
217 251
218 252 [Report]
@@ -58,9 +58,9
58 58 ShuntResistance = 0,001
59 59 Measurement_Check = False
60 60 DMM_VISAName = "PXI1Slot3"
61 DMM_ContactLimits = "<size(s)=2> 0,0 1,5"
61 DMM_ContactLimits = "<size(s)=2> 0,0 1,0"
62 62 TemperatureGain = "<size(s)=10> 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000"
63 TemperatureOffset = "<size(s)=10> 0,000000 0,000000 0,000000 0,500000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000"
63 TemperatureOffset = "<size(s)=10> 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000"
64 64 VoltageGain = "<size(s)=4> 1,000000 1,000000 1,000000 1,000000"
65 65 VoltageOffset = "<size(s)=4> 0,000000 0,000000 0,000000 0,000000"
66 66 AllowedContactFails = "2"
@@ -72,7 +72,7
72 72 PowerSupply_OutputVoltage = 3,000000
73 73 PowerSupply_OverVoltageProtection = 6,000000
74 74 DMM_Function = "2-wire Resistance"
75 DMM_AutoRange = False
75 DMM_AutoRange = True
76 76 DMM_Range = "0,020000"
77 77 DMM_Resolution = "0,001000"
78 78 Configuration_AI_Voltage.<size(s)> = "2"
@@ -84,61 +84,61
84 84 Configuration_AI_Voltage 1.InputTerminalConfiguration = "Differential"
85 85 Configuration_AI_Thermocouple.<size(s)> = "10"
86 86 Configuration_AI_Thermocouple 0.Maximum = "250,000000"
87 Configuration_AI_Thermocouple 0.Minimum = "-250,000000"
87 Configuration_AI_Thermocouple 0.Minimum = "-200,000000"
88 88 Configuration_AI_Thermocouple 0.Type = "K"
89 89 Configuration_AI_Thermocouple 0.CJC_Source = "Built-In"
90 90 Configuration_AI_Thermocouple 0.CJC_Value = "25,000000"
91 91 Configuration_AI_Thermocouple 0.Unit = "Deg C"
92 92 Configuration_AI_Thermocouple 1.Maximum = "250,000000"
93 Configuration_AI_Thermocouple 1.Minimum = "-250,000000"
93 Configuration_AI_Thermocouple 1.Minimum = "-200,000000"
94 94 Configuration_AI_Thermocouple 1.Type = "K"
95 95 Configuration_AI_Thermocouple 1.CJC_Source = "Built-In"
96 96 Configuration_AI_Thermocouple 1.CJC_Value = "25,000000"
97 97 Configuration_AI_Thermocouple 1.Unit = "Deg C"
98 98 Configuration_AI_Thermocouple 2.Maximum = "250,000000"
99 Configuration_AI_Thermocouple 2.Minimum = "-250,000000"
99 Configuration_AI_Thermocouple 2.Minimum = "-200,000000"
100 100 Configuration_AI_Thermocouple 2.Type = "K"
101 101 Configuration_AI_Thermocouple 2.CJC_Source = "Built-In"
102 102 Configuration_AI_Thermocouple 2.CJC_Value = "25,000000"
103 103 Configuration_AI_Thermocouple 2.Unit = "Deg C"
104 104 Configuration_AI_Thermocouple 3.Maximum = "250,000000"
105 Configuration_AI_Thermocouple 3.Minimum = "-250,000000"
105 Configuration_AI_Thermocouple 3.Minimum = "-200,000000"
106 106 Configuration_AI_Thermocouple 3.Type = "K"
107 107 Configuration_AI_Thermocouple 3.CJC_Source = "Constant Value"
108 108 Configuration_AI_Thermocouple 3.CJC_Value = "10,000000"
109 109 Configuration_AI_Thermocouple 3.Unit = "Deg C"
110 110 Configuration_AI_Thermocouple 4.Maximum = "250,000000"
111 Configuration_AI_Thermocouple 4.Minimum = "-250,000000"
111 Configuration_AI_Thermocouple 4.Minimum = "-200,000000"
112 112 Configuration_AI_Thermocouple 4.Type = "K"
113 113 Configuration_AI_Thermocouple 4.CJC_Source = "Built-In"
114 114 Configuration_AI_Thermocouple 4.CJC_Value = "25,000000"
115 115 Configuration_AI_Thermocouple 4.Unit = "Deg C"
116 116 Configuration_AI_Thermocouple 5.Maximum = "250,000000"
117 Configuration_AI_Thermocouple 5.Minimum = "-250,000000"
117 Configuration_AI_Thermocouple 5.Minimum = "-200,000000"
118 118 Configuration_AI_Thermocouple 5.Type = "K"
119 119 Configuration_AI_Thermocouple 5.CJC_Source = "Built-In"
120 120 Configuration_AI_Thermocouple 5.CJC_Value = "25,000000"
121 121 Configuration_AI_Thermocouple 5.Unit = "Deg C"
122 122 Configuration_AI_Thermocouple 6.Maximum = "250,000000"
123 Configuration_AI_Thermocouple 6.Minimum = "-250,000000"
123 Configuration_AI_Thermocouple 6.Minimum = "-200,000000"
124 124 Configuration_AI_Thermocouple 6.Type = "K"
125 125 Configuration_AI_Thermocouple 6.CJC_Source = "Built-In"
126 126 Configuration_AI_Thermocouple 6.CJC_Value = "25,000000"
127 127 Configuration_AI_Thermocouple 6.Unit = "Deg C"
128 128 Configuration_AI_Thermocouple 7.Maximum = "250,000000"
129 Configuration_AI_Thermocouple 7.Minimum = "-250,000000"
129 Configuration_AI_Thermocouple 7.Minimum = "-200,000000"
130 130 Configuration_AI_Thermocouple 7.Type = "K"
131 131 Configuration_AI_Thermocouple 7.CJC_Source = "Built-In"
132 132 Configuration_AI_Thermocouple 7.CJC_Value = "25,000000"
133 133 Configuration_AI_Thermocouple 7.Unit = "Deg C"
134 134 Configuration_AI_Thermocouple 8.Maximum = "250,000000"
135 Configuration_AI_Thermocouple 8.Minimum = "-250,000000"
135 Configuration_AI_Thermocouple 8.Minimum = "-200,000000"
136 136 Configuration_AI_Thermocouple 8.Type = "K"
137 137 Configuration_AI_Thermocouple 8.CJC_Source = "Built-In"
138 138 Configuration_AI_Thermocouple 8.CJC_Value = "25,000000"
139 139 Configuration_AI_Thermocouple 8.Unit = "Deg C"
140 140 Configuration_AI_Thermocouple 9.Maximum = "250,000000"
141 Configuration_AI_Thermocouple 9.Minimum = "-250,000000"
141 Configuration_AI_Thermocouple 9.Minimum = "-200,000000"
142 142 Configuration_AI_Thermocouple 9.Type = "K"
143 143 Configuration_AI_Thermocouple 9.CJC_Source = "Built-In"
144 144 Configuration_AI_Thermocouple 9.CJC_Value = "25,000000"
@@ -174,11 +174,44
174 174 PowerSupply_VISAName = "COM2"
175 175 PowerSupply_Address = "6"
176 176 PowerSupply_Baudrate = "9600"
177 PowerSupply_OutputVoltage = "8,000000"
178 PowerSupply_OverVoltageProtection = "9,000000"
177 179 DMM_Baudrate = "9600"
178 NI_USB6252_Out_LiftTable = "Dev1/port0/line5"
179 NI_USB6252_Out_SettingMode.<size(s)> = "2"
180 NI_USB6252_Out_SettingMode 0 = "Dev1/port0/line0"
181 NI_USB6252_Out_SettingMode 1 = "Dev1/port0/line1"
180 Measurement_Channels_AutoRange.<size(s)> = "13"
181 Measurement_Channels_AutoRange 0 = "TRUE"
182 Measurement_Channels_AutoRange 1 = "TRUE"
183 Measurement_Channels_AutoRange 2 = "TRUE"
184 Measurement_Channels_AutoRange 3 = "TRUE"
185 Measurement_Channels_AutoRange 4 = "TRUE"
186 Measurement_Channels_AutoRange 5 = "TRUE"
187 Measurement_Channels_AutoRange 6 = "TRUE"
188 Measurement_Channels_AutoRange 7 = "TRUE"
189 Measurement_Channels_AutoRange 8 = "TRUE"
190 Measurement_Channels_AutoRange 9 = "TRUE"
191 Measurement_Channels_AutoRange 10 = "TRUE"
192 Measurement_Channels_AutoRange 11 = "TRUE"
193 Measurement_Channels_AutoRange 12 = "TRUE"
194 Measurement_Channels_Range = "<size(s)=13> 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000"
195 Measurement_Channels_Resolution.<size(s)> = "13"
196 Measurement_Channels_Resolution 0 = "6.5"
197 Measurement_Channels_Resolution 1 = "6.5"
198 Measurement_Channels_Resolution 2 = "6.5"
199 Measurement_Channels_Resolution 3 = "6.5"
200 Measurement_Channels_Resolution 4 = "6.5"
201 Measurement_Channels_Resolution 5 = "6.5"
202 Measurement_Channels_Resolution 6 = "6.5"
203 Measurement_Channels_Resolution 7 = "6.5"
204 Measurement_Channels_Resolution 8 = "6.5"
205 Measurement_Channels_Resolution 9 = "6.5"
206 Measurement_Channels_Resolution 10 = "6.5"
207 Measurement_Channels_Resolution 11 = "6.5"
208 Measurement_Channels_Resolution 12 = "6.5"
209 Resistance_Function = "Resistance"
210 Resistance_OffsetCompensation = "FALSE"
211 TableControl_Out_LiftTable = "Dev1/port0/line5"
212 TableControl_Out_SettingMode.<size(s)> = "2"
213 TableControl_Out_SettingMode 0 = "Dev1/port0/line0"
214 TableControl_Out_SettingMode 1 = "Dev1/port0/line1"
182 215
183 216 [DefaultValues]
184 217 WorkingStroke = "0"