##// END OF EJS Templates
Delete file @ r60:61
  1
  2
  3
  4
  5
  6
  7
  8
  9
 10
 11
 12
 13
 14
 15
 16
 17
 18
 19
 20
 21
 22
 23
 24
 25
 26
 27
 28
 29
 30
 31
 32
 33
 34
 35
 36
 37
 38
 39
 40
 41
 42
 43
 44
 45
 46
 47
 48
 49
 50
 51
 52
 53
 54
 55
 56
 57
 58
 59
 60
 61
 62
 63
 64
 65
 66
 67
 68
 69
 70
 71
 72
 73
 74
 75
 76
 77
 78
 79
 80
 81
 82
 83
 84
 85
 86
 87
 88
 89
 90
 91
 92
 93
 94
 95
 96
 97
 98
 99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
[Tester]
TesterType = "EHF1"
TesterName = "Elektrischer Hochfrequenzmessplatz 1"
[Dashboard]
Name = "EHF1"
Path = "C:\Work\Labor-Dashboard\EHF1.html"
[cHardware]
POSConfig.IP = "10.1.2.1"
POSConfig.Port = "502"
POS_AxesNames.<size(s)> = "3"
POS_AxesNames 0 = "X"
POS_AxesNames 1 = "Y"
POS_AxesNames 2 = "Z"
POS_Reference_Axes = "<size(s)=3> 1,000000 1,000000 110,000000"
POS_Limits_Axis1 = "<size(s)=2> 0 210"
POS_Limits_Axis2 = "<size(s)=2> 0 242"
POS_Limits_Axis3 = "<size(s)=2> 0 111"
POS_AxesFlipped.<size(s)> = "3"
POS_AxesFlipped 0 = "True"
POS_AxesFlipped 1 = "True"
POS_AxesFlipped 2 = "False"
Pos_MaxVelocity = "300"
Pos_MaxVelocityUnblockedDoor = "20"
Pos_MaxAcceleration = "15000"
Pos_MaxAccelerationUnblockedDoor = "20"
Pos_MaxJerk = "140000"
Pos_MaxJerkUnblockedDoor = "14000"
ForceLimit_Axis3 = "<size(s)=5> 10,000000 5,000000 6,000000 7,000000 8,000000"
ForceLimit_Axis3_Text.<size(s)> = "5"
ForceLimit_Axis3_Text 0 = ""
ForceLimit_Axis3_Text 1 = "�30 N"
ForceLimit_Axis3_Text 2 = "�40 N"
ForceLimit_Axis3_Text 3 = "�50 N"
ForceLimit_Axis3_Text 4 = "�60 N"
ForceLimit_Axis3_AO_Limits = "<size(s)=2> 0,000000 10,000000"
AO_ForceLimit = "Dev0/Ao0"
DI_E-Stop = "Dev0/AuxPort/Di0"
DI_Door = "Dev0/AuxPort/Di1"
DC_Wait = "100"
DC_Device_1 = "USB-6509"
DC_Device_2 = "USB-6525"
CameraWindow.<size(s)> = "2"
CameraWindow 0 = "Kamera"
CameraWindow 1 = "Baumer Camera Explorer (64 Bit) v2.8.15736 "
DMMConfig.ResourceName = "COM1"
DMMConfig.Baudrate = "9600"
DMMConfig.ChannelList = "101,102,103,104,105,106,107,108,109,110"
ChargeMeterConfig.ResourceName = "COM10"
ChargeMeterConfig.Baudrate = "9600"
NetworkAnalyser.Names.<size(s)> = "3"
NetworkAnalyser.Names 0 = "Rohde & Schwarz (ZVA67)"
NetworkAnalyser.Names 1 = "Rohde & Schwarz (ZNL20)"
NetworkAnalyser.Names 2 = "Copper Mountain (Planar 804/1)"
NetworkAnalyser.ResourceNames.<size(s)> = "3"
NetworkAnalyser.ResourceNames 0 = "TCPIP0::10.1.2.30::inst0::INSTR"
NetworkAnalyser.ResourceNames 1 = "TCPIP0::10.1.2.10::inst0::INSTR"
NetworkAnalyser.ResourceNames 2 = ""
NetworkAnalyser.StateFilesFolder.<size(s)> = "3"
NetworkAnalyser.StateFilesFolder 0 = "C:\Rohde&Schwarz\Nwa\Calibration\RecallSets\"
NetworkAnalyser.StateFilesFolder 1 = "C:\Users\Public\Documents\Rohde-Schwarz\ZNL\Calibration\RecallSets\"
NetworkAnalyser.StateFilesFolder 2 = "C:\Work\PositioningSystem\support\Planar804\StateFiles"
NetworkAnalyser.TestResultFolder.<size(s)> = "3"
NetworkAnalyser.TestResultFolder 0 = "C:\Work\PositioningSystem\support\ZVA67\"
NetworkAnalyser.TestResultFolder 1 = "C:\Work\PositioningSystem\support\ZNL20\"
NetworkAnalyser.TestResultFolder 2 = "C:\Work\PositioningSystem\support\Planar804\"
NetworkAnalyser.TestResultFormat = "%d.%m.%Y-%H%M%S"
NetworkAnalyser.ResultFolder.<size(s)> = "3"
NetworkAnalyser.ResultFolder 0 = "C:\Work\PositioningSystem\support\ZVA67\"
NetworkAnalyser.ResultFolder 1 = "C:\Work\PositioningSystem\support\ZNL20\"
NetworkAnalyser.ResultFolder 2 = "C:\Work\PositioningSystem\support\Planar804\"
NetworkAnalyser.ResultFormat = "%d.%m.%Y-%H%M%S_HF"
NetworkAnalyser.CommonMemory.<size(s)> = "2"
NetworkAnalyser.CommonMemory 0 = "Z:\"
NetworkAnalyser.CommonMemory 1 = "D:\Testdaten\"
[cPathes]
pUser = "C:\Work\PositioningSystem\support\User.txt"
pResultsFolder = "C:\Work\PositioningSystem\support\ResultData"
pGraphs = "C:\Work\PositioningSystem\support\Temp"
pExcelReports = "C:\Work\PositioningSystem\support\Temp"
pTestRun = "C:\Work\PositioningSystem\support\TestRuns"
pMatrix = "C:\Work\PositioningSystem\support\Matrixes"
pDC = "C:\Work\PositioningSystem\support\DC-Configurations"
pNote = "C:\Work\PositioningSystem\support\Note.txt"
pLimits = "C:\Work\PositioningSystem\support\Limits"
pNetwork = "C:\Work\PositioningSystem\support\CopyFolder"
[cDefaultValues]
MovingParameter.Velocity = "20,000000"
MovingParameter.Acceleration = "50,000000"
MovingParameter.Jerk = "140000,000000"
ForceLimit_Z = "0"
Learning_Steps.Axis1 = "0,0500000"
Learning_Steps.Axis2 = "0,0500000"
Learning_Steps.Axis3 = "1,000000"
Learning_ZStopOffset = "-2,000000"
Learning_Measurements = "3"
Learning_NetworkAnalyser = "0"
Comment = ""
Matrix_WorkingStroke = "4,000000"
Matrix_Z- = "1,000000"
Matrix_Contacts = "1"
Matrix_XDelta = "1,000000"
Matrix_XSize = "2"
Matrix_YDelta = "1,000000"
Matrix_YSize = "2"
Colors = "<size(s)=10> 16776960 16744448 16744640 16711935 10879142 8388863 8421631 423327 3381759 9567230"
TestRun_LoopsNumber = "2"
TestRun_Delay = "100"
TestRun_-Z = "1"
TestRun_Stroke = "4"
TestRun_Time = "0"
TestRun_StrokesNumber = "10"
[cReport]
FileNameFormat = "%s_TestProtocol.txt"
FileNameFormat_Standard = "%d.%m.%Y-%H%M%S_Standard.csv"
FileNameFormat_DC = "%d.%m.%Y-%H%M%S_DC.csv"
FileNameFormat_Position = "%d.%m.%Y-%H%M%S_Position.csv"
FileNameFormat_Camera = "%d.%m.%Y-%H%M%S.png"
ReportNameFormat = "%s_TestReport.xlsx"
ReportTemplate_German = "C:\Work\PositioningSystem\support\ReportTemplates\TemplateGerman.xlsx"
ReportTemplate_English = "C:\Work\PositioningSystem\support\ReportTemplates\TemplateEnglish.xlsx"
ForceTemplate = "C:\Work\PositioningSystem\support\ReportTemplates\ForceTemplate.xlsx"
ResistanceForceDistanceTemplate = "C:\Work\PositioningSystem\support\ReportTemplates\ResistanceForceDistanceTemplate.xlsx"
StandardTemplate.<size(s)> = "4"
StandardTemplate 0 = "C:\Work\PositioningSystem\support\ReportTemplates\StandardTemplate.xlsx"
StandardTemplate 1 = "C:\Work\PositioningSystem\support\ReportTemplates\StandardTemplate.xlsx"
StandardTemplate 2 = "C:\Work\PositioningSystem\support\ReportTemplates\StandardTemplate_Common.xlsx"
StandardTemplate 3 = "C:\Work\PositioningSystem\support\ReportTemplates\StandardTemplate_Increment.xlsx"
StandardTemplate_Macro = "C:\Work\PositioningSystem\support\ReportTemplates\Macro.bas"
StandardTemplate_Scripts.<size(s)> = "7"
StandardTemplate_Scripts 0 = "AktualisiereXYDiagrammWiderstand"
StandardTemplate_Scripts 1 = "AktualisiereXYDiagrammKraft"
StandardTemplate_Scripts 2 = "AktualisiereXYDiagrammInkrementWiderstand"
StandardTemplate_Scripts 3 = "AktualisiereXYDiagrammInkrementKraft"
StandardTemplate_Scripts 4 = "AktualisiereXYDiagrammInkrementWiderstandPosition"
StandardTemplate_Scripts 5 = "AktualisiereXYDiagrammInkrementKraftPosition"
StandardTemplate_Scripts 6 = "AktualisiereXYDiagrammHF"
DCTemplate = "C:\Work\PositioningSystem\support\ReportTemplates\DCTemplate.xlsx"
PositionTemplate = "C:\Work\PositioningSystem\support\ReportTemplates\PositionTemplate.xlsx"
HFTemplate = "C:\Work\PositioningSystem\support\ReportTemplates\HFTemplate.xlsx"
CameraSubset.Left = "274"
CameraSubset.Top = "40"
CameraSubset.Right = "1616"
CameraSubset.Bottom = "1048"
[cStateMessages]
Info.<size(s)> = "32"
Info 0 = "Not-Halt aktiviert!"
Info 1 = "Einrichtbetrieb f�r Achsensteuerung aktiviert! Nur manuelle Positionierung m�glich"
Info 2 = "T�r ist freigegeben! Nur manuelle Positionierung m�glich"
Info 3 = "Positioniereinheit wird initialisiert! Bitte warten..."
Info 4 = "Datenerfassungssystem wird initialisiert! Bitte warten..."
Info 5 = "Ladungsverst�rker wird initialisiert! Bitte warten..."
Info 6 = "Netzwerkanalysator wird initialisiert! Bitte warten..."
Info 7 = "Zum Anlegen eines neuen Tests "Neuer Test" klicken"
Info 8 = "Testdaten anlegen"
Info 9 = "Lernfahrten"
Info 10 = "Achsen werden initialisiert..."
Info 11 = "Referenzfahrt l�uft..."
Info 12 = "X-Achse wird referenziert..."
Info 13 = "Y-Achse wird referenziert..."
Info 14 = "Z-Achse wird referenziert..."
Info 15 = "Position wird angefahren..."
Info 16 = "Kraftmessung wird durchgef�hrt..."
Info 17 = "Widerstand/Kraftmessung wird durchgef�hrt..."
Info 18 = "Kamerabild wird gespeichert..."
Info 19 = "Testablauf"
Info 20 = "Test geladen"
Info 21 = "Laufender Test..."
Info 22 = "Verz�gerung l�uft..."
Info 23 = "Messung wird durchgef�hrt..."
Info 24 = "Lastwechsel wird ausgef�hrt..."
Info 25 = "Test erfolgreich abgeschlossen"
Info 26 = "Test bestanden"
Info 27 = "Test fehlgeschlagen"
Info 28 = "Fehler aufgetreten!"
Info 29 = "Test abgebrochen!"
Info 30 = "Messergebnisse werden exportiert... Bitte warten"
Info 31 = "Messergebnisse wurden exportiert"
Result.<size(s)> = "32"
Result 0 = "Not-Halt"
Result 1 = ""
Result 2 = ""
Result 3 = ""
Result 4 = "Einrichtbetrieb"
Result 5 = "Einrichtbetrieb"
Result 6 = "Einrichtbetrieb"
Result 7 = ""
Result 8 = ""
Result 9 = "Einrichtbetrieb"
Result 10 = "Einrichtbetrieb"
Result 11 = "Einrichtbetrieb"
Result 12 = "Einrichtbetrieb"
Result 13 = "Einrichtbetrieb"
Result 14 = "Einrichtbetrieb"
Result 15 = "Einrichtbetrieb"
Result 16 = "Einrichtbetrieb"
Result 17 = "Einrichtbetrieb"
Result 18 = ""
Result 19 = ""
Result 20 = ""
Result 21 = "Test l�uft"
Result 22 = "Test l�uft"
Result 23 = "Einrichtbetrieb"
Result 24 = "Test l�uft"
Result 25 = "Fertig"
Result 26 = "Bestanden"
Result 27 = "Fehlgeschlagen"
Result 28 = "Fehler"
Result 29 = "Stop"
Result 30 = ""
Result 31 = ""
[cDialogMessages]
Messages.<size(s)> = "15"
Messages 0 = "W�hlen Sie eine Testkonfigurationsdatei zum Laden aus"
Messages 1 = "W�hlen Sie einen Ordner aus, der die Testergebnisse zum Laden enth�lt"
Messages 2 = "Die Merkzetteldaten werden gel�scht!\0ABitte best�tigen Sie die Operation oder schlie�en Sie das Dialogfeld, um den Vorgang abzubrechen ..."
Messages 3 = "W�hlen Sie einen Testablauf zum Laden aus"
Messages 4 = "Geben Sie einen Namen f�r den Testablauf ein"
Messages 5 = "Die Testmatrix wird gel�scht!\0ABitte best�tigen Sie die Operation oder schlie�en Sie das Dialogfeld, um den Vorgang abzubrechen ..."
Messages 6 = "W�hlen Sie eine Testmatrix zum Laden aus"
Messages 7 = "Geben Sie einen Namen f�r die Testmatrix ein"
Messages 8 = "W�hlen Sie eine DC-Konfiguration zum Laden aus"
Messages 9 = "Geben Sie einen Namen f�r die DC-Konfiguration ein"
Messages 10 = "W�hlen Sie eine Vorlage aus:"
Messages 11 = "Test wurde abgebrochen.\0AOption zur Achseninitialisierung w�hlen oder abbrechen."
Messages 12 = "Geben Sie einen Namen f�r die Limits ein"
Messages 13 = "W�hlen Sie die Parameter f�r die �berschreibung aller ausgew�hlten Positionen aus und geben Sie diese ein:"
Messages 14 = "Kein HF-Testschritt mit Radiusmessung und Testbestehenskriterien"
[cCAQ]
Login = "EHF1-Tester"
Pw = "EHF1-Tester"
AuthIDFile = ""
AuthID = "XB2F9FAFD5559F4FB5B92FE524B40D8A3C"
MAPNumber = 130
LocationName = "GKS Montage HF-Tester"