[Tester]
|
|
|
TesterType = "HSMP2"
|
|
|
TesterName = "Hochstrommessplatz 2"
|
|
|
MaxCurrent = 2000
|
|
|
MaxTemperature = 250
|
|
|
MaxAmbientTemperature = 50
|
|
|
SensorsEnable.<size(s)> = "15"
|
|
|
SensorsEnable 0 = "True"
|
|
|
SensorsEnable 1 = "True"
|
|
|
SensorsEnable 2 = "True"
|
|
|
SensorsEnable 3 = "True"
|
|
|
SensorsEnable 4 = "True"
|
|
|
SensorsEnable 5 = "True"
|
|
|
SensorsEnable 6 = "True"
|
|
|
SensorsEnable 7 = "False"
|
|
|
SensorsEnable 8 = "False"
|
|
|
SensorsEnable 9 = "False"
|
|
|
SensorsEnable 10 = "False"
|
|
|
SensorsEnable 11 = "False"
|
|
|
SensorsEnable 12 = "False"
|
|
|
SensorsEnable 13 = "False"
|
|
|
SensorsEnable 14 = "False"
|
|
|
SensorsDescription.<size(s)> = "15"
|
|
|
SensorsDescription 0 = "NI-9212: Ch1"
|
|
|
SensorsDescription 1 = "NI-9212: Ch2"
|
|
|
SensorsDescription 2 = "NI-9212: Ch3"
|
|
|
SensorsDescription 3 = "NI-9212: Ch4"
|
|
|
SensorsDescription 4 = "NI-9219_1: Ch1"
|
|
|
SensorsDescription 5 = "NI-9219_1: Ch2"
|
|
|
SensorsDescription 6 = "NI-9219_1: Ch3"
|
|
|
SensorsDescription 7 = "NI-9219_2: Ch1"
|
|
|
SensorsDescription 8 = "NI-9219_2: Ch2"
|
|
|
SensorsDescription 9 = "NI-9219_2: Ch3"
|
|
|
SensorsDescription 10 = "NI-9219_2: Ch4"
|
|
|
SensorsDescription 11 = "NI-9219_3: Ch1"
|
|
|
SensorsDescription 12 = "NI-9219_3: Ch2"
|
|
|
SensorsDescription 13 = "NI-9219_3: Ch3"
|
|
|
SensorsDescription 14 = "NI-9219_3: Ch4"
|
|
|
VoltageDescription.<size(s)> = "5 2"
|
|
|
VoltageDescription 0 = "NI-9215: Ch1"
|
|
|
VoltageDescription 1 = "Pr�flingsspannung [V]"
|
|
|
VoltageDescription 2 = "NI-9215: Ch2"
|
|
|
VoltageDescription 3 = "Zero Flux- Spannung [V]"
|
|
|
VoltageDescription 4 = ""
|
|
|
VoltageDescription 5 = "Strom [A]"
|
|
|
VoltageDescription 6 = ""
|
|
|
VoltageDescription 7 = "Widerstand [mOhm]"
|
|
|
VoltageDescription 8 = ""
|
|
|
VoltageDescription 9 = "Leistung [W]"
|
|
|
CalibrationPassword = "48c8947f69c054a5caa934674ce8881d02bb18fb59d5a63eeaddff735b0e9801e87294783281ae49fc8287a0fd86779b27d7972d3e84f0fa0d826d7cb67dfefc"
|
|
|
|
|
|
[Hardware]
|
|
|
SimulateDevices = False
|
|
|
DI_E-Stop = ""
|
|
|
DI_Setup = ""
|
|
|
PowerSupply_VISAName = "COM4"
|
|
|
PowerSupply_Address = "0"
|
|
|
PowerSupply_Baudrate = "9600"
|
|
|
PowerSupply_OutputVoltage = "10,000000"
|
|
|
PowerSupply_OverVoltageProtection = "9,800000"
|
|
|
PowerSupply_MinCurrent = "0"
|
|
|
PowerSupply_Check = False
|
|
|
PowerSupply_WarningPower = "18000,000000"
|
|
|
PowerSupply_AbortPower = "20000,000000"
|
|
|
PowerSupply_PID = "FALSE"
|
|
|
PowerSupply_PID_Time = "0,100000"
|
|
|
PowerSupply_PID_ProportionalGain = "0,100000"
|
|
|
PowerSupply_PID_IntegralTime = "0,180000"
|
|
|
PowerSupply_PID_DerivativeTime = "0,000000"
|
|
|
AbortCurrentDifference = "0,000000"
|
|
|
Measurement_Channels.<size(s)> = "17"
|
|
|
Measurement_Channels 0 = "NI9215/ai0"
|
|
|
Measurement_Channels 1 = "NI9215/ai1"
|
|
|
Measurement_Channels 2 = "NI9212/ai0"
|
|
|
Measurement_Channels 3 = "NI9212/ai1"
|
|
|
Measurement_Channels 4 = "NI9212/ai2"
|
|
|
Measurement_Channels 5 = "NI9212/ai3"
|
|
|
Measurement_Channels 6 = "NI9219_1/ai0"
|
|
|
Measurement_Channels 7 = "NI9219_1/ai1"
|
|
|
Measurement_Channels 8 = "NI9219_1/ai2"
|
|
|
Measurement_Channels 9 = "NI9219_2/ai0"
|
|
|
Measurement_Channels 10 = "NI9219_2/ai1"
|
|
|
Measurement_Channels 11 = "NI9219_2/ai2"
|
|
|
Measurement_Channels 12 = "NI9219_2/ai3"
|
|
|
Measurement_Channels 13 = "NI9219_3/ai0"
|
|
|
Measurement_Channels 14 = "NI9219_3/ai1"
|
|
|
Measurement_Channels 15 = "NI9219_3/ai2"
|
|
|
Measurement_Channels 16 = "NI9219_3/ai3"
|
|
|
Measurement_Sample = "<size(s)=17> 40,000000 40,000000 2,000000 2,000000 2,000000 2,000000 40,000000 40,000000 40,000000 40,000000 40,000000 40,000000 40,000000 40,000000 40,000000 40,000000 40,000000"
|
|
|
ShuntResistance = "0,005"
|
|
|
Measurement_Check = False
|
|
|
DMM_VISAName = "NI9219_1/ai3"
|
|
|
DMM_ContactLimits = "<size(s)=2> 0,000000 10,000000"
|
|
|
TemperatureGain = "<size(s)=15> 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000"
|
|
|
TemperatureOffset = "<size(s)=15> 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000"
|
|
|
VoltageGain = "<size(s)=5> 1,000000 1,000000 1,000000 1,000000 1,000000"
|
|
|
VoltageOffset = "<size(s)=5> 0,000000 0,000000 0,000000 0,000000 0,000000"
|
|
|
AllowedContactFails = "2"
|
|
|
|
|
|
[HSMP2]
|
|
|
DMM_Configuration.Maximum = "10,000000"
|
|
|
DMM_Configuration.Minimum = "0,000000"
|
|
|
DMM_Configuration.Configuration = "2-Wire"
|
|
|
DMM_Configuration.CurrentExcitationSource = "Internal"
|
|
|
DMM_Configuration.CurrentExcitationValue = "0,000500"
|
|
|
DMM_Sample = "40,000000"
|
|
|
Configuration_AI_Voltage.<size(s)> = "2"
|
|
|
Configuration_AI_Voltage 0.Maximum = "10,000000"
|
|
|
Configuration_AI_Voltage 0.Minimum = "-10,000000"
|
|
|
Configuration_AI_Voltage 0.InputTerminalConfiguration = "Differential"
|
|
|
Configuration_AI_Voltage 1.Maximum = "10,000000"
|
|
|
Configuration_AI_Voltage 1.Minimum = "0,000000"
|
|
|
Configuration_AI_Voltage 1.InputTerminalConfiguration = "Differential"
|
|
|
Configuration_AI_Thermocouple.<size(s)> = "15"
|
|
|
Configuration_AI_Thermocouple 0.Maximum = "250,000000"
|
|
|
Configuration_AI_Thermocouple 0.Minimum = "-200,000000"
|
|
|
Configuration_AI_Thermocouple 0.Type = "K"
|
|
|
Configuration_AI_Thermocouple 0.CJC_Source = "Built-In"
|
|
|
Configuration_AI_Thermocouple 0.CJC_Value = "25,000000"
|
|
|
Configuration_AI_Thermocouple 1.Maximum = "250,000000"
|
|
|
Configuration_AI_Thermocouple 1.Minimum = "-200,000000"
|
|
|
Configuration_AI_Thermocouple 1.Type = "K"
|
|
|
Configuration_AI_Thermocouple 1.CJC_Source = "Built-In"
|
|
|
Configuration_AI_Thermocouple 1.CJC_Value = "25,000000"
|
|
|
Configuration_AI_Thermocouple 2.Maximum = "250,000000"
|
|
|
Configuration_AI_Thermocouple 2.Minimum = "-200,000000"
|
|
|
Configuration_AI_Thermocouple 2.Type = "K"
|
|
|
Configuration_AI_Thermocouple 2.CJC_Source = "Built-In"
|
|
|
Configuration_AI_Thermocouple 2.CJC_Value = "25,000000"
|
|
|
Configuration_AI_Thermocouple 3.Maximum = "250,000000"
|
|
|
Configuration_AI_Thermocouple 3.Minimum = "-200,000000"
|
|
|
Configuration_AI_Thermocouple 3.Type = "K"
|
|
|
Configuration_AI_Thermocouple 3.CJC_Source = "Built-In"
|
|
|
Configuration_AI_Thermocouple 3.CJC_Value = "10,000000"
|
|
|
Configuration_AI_Thermocouple 4.Maximum = "250,000000"
|
|
|
Configuration_AI_Thermocouple 4.Minimum = "-200,000000"
|
|
|
Configuration_AI_Thermocouple 4.Type = "K"
|
|
|
Configuration_AI_Thermocouple 4.CJC_Source = "Built-In"
|
|
|
Configuration_AI_Thermocouple 4.CJC_Value = "25,000000"
|
|
|
Configuration_AI_Thermocouple 5.Maximum = "250,000000"
|
|
|
Configuration_AI_Thermocouple 5.Minimum = "-200,000000"
|
|
|
Configuration_AI_Thermocouple 5.Type = "K"
|
|
|
Configuration_AI_Thermocouple 5.CJC_Source = "Built-In"
|
|
|
Configuration_AI_Thermocouple 5.CJC_Value = "25,000000"
|
|
|
Configuration_AI_Thermocouple 6.Maximum = "250,000000"
|
|
|
Configuration_AI_Thermocouple 6.Minimum = "-200,000000"
|
|
|
Configuration_AI_Thermocouple 6.Type = "K"
|
|
|
Configuration_AI_Thermocouple 6.CJC_Source = "Built-In"
|
|
|
Configuration_AI_Thermocouple 6.CJC_Value = "25,000000"
|
|
|
Configuration_AI_Thermocouple 7.Maximum = "250,000000"
|
|
|
Configuration_AI_Thermocouple 7.Minimum = "-200,000000"
|
|
|
Configuration_AI_Thermocouple 7.Type = "K"
|
|
|
Configuration_AI_Thermocouple 7.CJC_Source = "Built-In"
|
|
|
Configuration_AI_Thermocouple 7.CJC_Value = "25,000000"
|
|
|
Configuration_AI_Thermocouple 8.Maximum = "250,000000"
|
|
|
Configuration_AI_Thermocouple 8.Minimum = "-200,000000"
|
|
|
Configuration_AI_Thermocouple 8.Type = "K"
|
|
|
Configuration_AI_Thermocouple 8.CJC_Source = "Built-In"
|
|
|
Configuration_AI_Thermocouple 8.CJC_Value = "25,000000"
|
|
|
Configuration_AI_Thermocouple 9.Maximum = "250,000000"
|
|
|
Configuration_AI_Thermocouple 9.Minimum = "-200,000000"
|
|
|
Configuration_AI_Thermocouple 9.Type = "K"
|
|
|
Configuration_AI_Thermocouple 9.CJC_Source = "Built-In"
|
|
|
Configuration_AI_Thermocouple 9.CJC_Value = "25,000000"
|
|
|
Configuration_AI_Thermocouple 10.Maximum = "250,000000"
|
|
|
Configuration_AI_Thermocouple 10.Minimum = "-200,000000"
|
|
|
Configuration_AI_Thermocouple 10.Type = "K"
|
|
|
Configuration_AI_Thermocouple 10.CJC_Source = "Built-In"
|
|
|
Configuration_AI_Thermocouple 10.CJC_Value = "25,000000"
|
|
|
Configuration_AI_Thermocouple 11.Maximum = "250,000000"
|
|
|
Configuration_AI_Thermocouple 11.Minimum = "-200,000000"
|
|
|
Configuration_AI_Thermocouple 11.Type = "K"
|
|
|
Configuration_AI_Thermocouple 11.CJC_Source = "Built-In"
|
|
|
Configuration_AI_Thermocouple 11.CJC_Value = "25,000000"
|
|
|
Configuration_AI_Thermocouple 12.Maximum = "250,000000"
|
|
|
Configuration_AI_Thermocouple 12.Minimum = "-200,000000"
|
|
|
Configuration_AI_Thermocouple 12.Type = "K"
|
|
|
Configuration_AI_Thermocouple 12.CJC_Source = "Built-In"
|
|
|
Configuration_AI_Thermocouple 12.CJC_Value = "25,000000"
|
|
|
Configuration_AI_Thermocouple 13.Maximum = "250,000000"
|
|
|
Configuration_AI_Thermocouple 13.Minimum = "-200,000000"
|
|
|
Configuration_AI_Thermocouple 13.Type = "K"
|
|
|
Configuration_AI_Thermocouple 13.CJC_Source = "Built-In"
|
|
|
Configuration_AI_Thermocouple 13.CJC_Value = "10,000000"
|
|
|
Configuration_AI_Thermocouple 14.Maximum = "250,000000"
|
|
|
Configuration_AI_Thermocouple 14.Minimum = "-200,000000"
|
|
|
Configuration_AI_Thermocouple 14.Type = "K"
|
|
|
Configuration_AI_Thermocouple 14.CJC_Source = "Built-In"
|
|
|
Configuration_AI_Thermocouple 14.CJC_Value = "25,000000"
|
|
|
Configuration_AI_NI9219_Resistance.<size(s)> = "11"
|
|
|
Configuration_AI_NI9219_Resistance 0.Maximum = "800,000000"
|
|
|
Configuration_AI_NI9219_Resistance 0.Minimum = "0,000000"
|
|
|
Configuration_AI_NI9219_Resistance 0.Configuration = "4-Wire"
|
|
|
Configuration_AI_NI9219_Resistance 0.CurrentExcitationSource = "Internal"
|
|
|
Configuration_AI_NI9219_Resistance 0.CurrentExcitationValue = "0,000500"
|
|
|
Configuration_AI_NI9219_Resistance 0.RTD_Type = "Pt3750"
|
|
|
Configuration_AI_NI9219_Resistance 0.R0 = "1000,000000"
|
|
|
Configuration_AI_NI9219_Resistance 0.ABC = "<size(s)=3> 1,224312924E-3 2,308955523E-4 3,938074268E-9"
|
|
|
Configuration_AI_NI9219_Resistance 1.Maximum = "800,000000"
|
|
|
Configuration_AI_NI9219_Resistance 1.Minimum = "0,000000"
|
|
|
Configuration_AI_NI9219_Resistance 1.Configuration = "4-Wire"
|
|
|
Configuration_AI_NI9219_Resistance 1.CurrentExcitationSource = "Internal"
|
|
|
Configuration_AI_NI9219_Resistance 1.CurrentExcitationValue = "0,000500"
|
|
|
Configuration_AI_NI9219_Resistance 1.RTD_Type = "Pt3750"
|
|
|
Configuration_AI_NI9219_Resistance 1.R0 = "1000,000000"
|
|
|
Configuration_AI_NI9219_Resistance 1.ABC = "<size(s)=3> 1,224312924E-3 2,308955523E-4 3,938074268E-9"
|
|
|
Configuration_AI_NI9219_Resistance 2.Maximum = "10500,000000"
|
|
|
Configuration_AI_NI9219_Resistance 2.Minimum = "0,000000"
|
|
|
Configuration_AI_NI9219_Resistance 2.Configuration = "2-Wire"
|
|
|
Configuration_AI_NI9219_Resistance 2.CurrentExcitationSource = "Internal"
|
|
|
Configuration_AI_NI9219_Resistance 2.CurrentExcitationValue = "0,000500"
|
|
|
Configuration_AI_NI9219_Resistance 2.RTD_Type = "Pt3750"
|
|
|
Configuration_AI_NI9219_Resistance 2.R0 = "1000,000000"
|
|
|
Configuration_AI_NI9219_Resistance 2.ABC = "<size(s)=3> 3,81E-3 -6,02E-7 -6E-12"
|
|
|
Configuration_AI_NI9219_Resistance 3.Maximum = "250,000000"
|
|
|
Configuration_AI_NI9219_Resistance 3.Minimum = "0,000000"
|
|
|
Configuration_AI_NI9219_Resistance 3.Configuration = "2-Wire"
|
|
|
Configuration_AI_NI9219_Resistance 3.CurrentExcitationSource = "Internal"
|
|
|
Configuration_AI_NI9219_Resistance 3.CurrentExcitationValue = "0,000500"
|
|
|
Configuration_AI_NI9219_Resistance 3.RTD_Type = "Pt3750"
|
|
|
Configuration_AI_NI9219_Resistance 3.R0 = "1000,000000"
|
|
|
Configuration_AI_NI9219_Resistance 3.ABC = "<size(s)=3> 1,224312924E-3 2,308955523E-4 3,938074268E-9"
|
|
|
Configuration_AI_NI9219_Resistance 4.Maximum = "10500,000000"
|
|
|
Configuration_AI_NI9219_Resistance 4.Minimum = "0,000000"
|
|
|
Configuration_AI_NI9219_Resistance 4.Configuration = "2-Wire"
|
|
|
Configuration_AI_NI9219_Resistance 4.CurrentExcitationSource = "Internal"
|
|
|
Configuration_AI_NI9219_Resistance 4.CurrentExcitationValue = "0,000500"
|
|
|
Configuration_AI_NI9219_Resistance 4.RTD_Type = "Pt3750"
|
|
|
Configuration_AI_NI9219_Resistance 4.R0 = "1000,000000"
|
|
|
Configuration_AI_NI9219_Resistance 4.ABC = "<size(s)=3> 0,001224 0,000231 3,938074E-9"
|
|
|
Configuration_AI_NI9219_Resistance 5.Maximum = "250,000000"
|
|
|
Configuration_AI_NI9219_Resistance 5.Minimum = "0,000000"
|
|
|
Configuration_AI_NI9219_Resistance 5.Configuration = "2-Wire"
|
|
|
Configuration_AI_NI9219_Resistance 5.CurrentExcitationSource = "Internal"
|
|
|
Configuration_AI_NI9219_Resistance 5.CurrentExcitationValue = "0,000500"
|
|
|
Configuration_AI_NI9219_Resistance 5.RTD_Type = "Pt3750"
|
|
|
Configuration_AI_NI9219_Resistance 5.R0 = "1000,000000"
|
|
|
Configuration_AI_NI9219_Resistance 5.ABC = "<size(s)=3> 0,001224 0,000231 3,938074E-9"
|
|
|
Configuration_AI_NI9219_Resistance 6.Maximum = "250,000000"
|
|
|
Configuration_AI_NI9219_Resistance 6.Minimum = "0,000000"
|
|
|
Configuration_AI_NI9219_Resistance 6.Configuration = "2-Wire"
|
|
|
Configuration_AI_NI9219_Resistance 6.CurrentExcitationSource = "Internal"
|
|
|
Configuration_AI_NI9219_Resistance 6.CurrentExcitationValue = "0,000500"
|
|
|
Configuration_AI_NI9219_Resistance 6.RTD_Type = "Pt3750"
|
|
|
Configuration_AI_NI9219_Resistance 6.R0 = "1000,000000"
|
|
|
Configuration_AI_NI9219_Resistance 6.ABC = "<size(s)=3> 0,003810 -6,020000E-7 -6,000000E-12"
|
|
|
Configuration_AI_NI9219_Resistance 7.Maximum = "250,000000"
|
|
|
Configuration_AI_NI9219_Resistance 7.Minimum = "-200,000000"
|
|
|
Configuration_AI_NI9219_Resistance 7.Configuration = "4-Wire"
|
|
|
Configuration_AI_NI9219_Resistance 7.CurrentExcitationSource = "Internal"
|
|
|
Configuration_AI_NI9219_Resistance 7.CurrentExcitationValue = "0,000500"
|
|
|
Configuration_AI_NI9219_Resistance 7.RTD_Type = "Pt3750"
|
|
|
Configuration_AI_NI9219_Resistance 7.R0 = "1000,000000"
|
|
|
Configuration_AI_NI9219_Resistance 7.ABC = "<size(s)=3> 0,001224 0,000231 3,938074E-9"
|
|
|
Configuration_AI_NI9219_Resistance 8.Maximum = "200,000000"
|
|
|
Configuration_AI_NI9219_Resistance 8.Minimum = "-10,000000"
|
|
|
Configuration_AI_NI9219_Resistance 8.Configuration = "4-Wire"
|
|
|
Configuration_AI_NI9219_Resistance 8.CurrentExcitationSource = "Internal"
|
|
|
Configuration_AI_NI9219_Resistance 8.CurrentExcitationValue = "0,000500"
|
|
|
Configuration_AI_NI9219_Resistance 8.RTD_Type = "Pt3750"
|
|
|
Configuration_AI_NI9219_Resistance 8.R0 = "1000,000000"
|
|
|
Configuration_AI_NI9219_Resistance 8.ABC = "<size(s)=3> 0,001224 0,000231 3,938074E-9"
|
|
|
Configuration_AI_NI9219_Resistance 9.Maximum = "250,000000"
|
|
|
Configuration_AI_NI9219_Resistance 9.Minimum = "0,000000"
|
|
|
Configuration_AI_NI9219_Resistance 9.Configuration = "4-Wire"
|
|
|
Configuration_AI_NI9219_Resistance 9.CurrentExcitationSource = "Internal"
|
|
|
Configuration_AI_NI9219_Resistance 9.CurrentExcitationValue = "0,000500"
|
|
|
Configuration_AI_NI9219_Resistance 9.RTD_Type = "Pt3750"
|
|
|
Configuration_AI_NI9219_Resistance 9.R0 = "1000,000000"
|
|
|
Configuration_AI_NI9219_Resistance 9.ABC = "<size(s)=3> 0,001224 0,000231 3,938074E-9"
|
|
|
Configuration_AI_NI9219_Resistance 10.Maximum = "250,000000"
|
|
|
Configuration_AI_NI9219_Resistance 10.Minimum = "0,000000"
|
|
|
Configuration_AI_NI9219_Resistance 10.Configuration = "2-Wire"
|
|
|
Configuration_AI_NI9219_Resistance 10.CurrentExcitationSource = "Internal"
|
|
|
Configuration_AI_NI9219_Resistance 10.CurrentExcitationValue = "0,000500"
|
|
|
Configuration_AI_NI9219_Resistance 10.RTD_Type = "Pt3750"
|
|
|
Configuration_AI_NI9219_Resistance 10.R0 = "1000,000000"
|
|
|
Configuration_AI_NI9219_Resistance 10.ABC = "<size(s)=3> 0,003810 -6,020000E-7 -6,000000E-12"
|
|
|
Configuration_AI_NI9219_Type.<size(s)> = "11"
|
|
|
Configuration_AI_NI9219_Type 0 = "RTD"
|
|
|
Configuration_AI_NI9219_Type 1 = "RTD"
|
|
|
Configuration_AI_NI9219_Type 2 = "Resistance_RTD"
|
|
|
Configuration_AI_NI9219_Type 3 = "Resistance_Thermistor"
|
|
|
Configuration_AI_NI9219_Type 4 = "Resistance_Thermistor"
|
|
|
Configuration_AI_NI9219_Type 5 = "Resistance_Thermistor"
|
|
|
Configuration_AI_NI9219_Type 6 = "Resistance_Thermistor"
|
|
|
Configuration_AI_NI9219_Type 7 = "RTD"
|
|
|
Configuration_AI_NI9219_Type 8 = "RTD"
|
|
|
Configuration_AI_NI9219_Type 9 = "RTD"
|
|
|
Configuration_AI_NI9219_Type 10 = "Resistance_RTD"
|
|
|
POS_Config.IP = "10.1.2.1"
|
|
|
POS_Config.Port = "502"
|
|
|
POS_AxesNames.<size(s)> = "3"
|
|
|
POS_AxesNames 0 = "X"
|
|
|
POS_AxesNames 1 = "Y"
|
|
|
POS_AxesNames 2 = "Z"
|
|
|
POS_Reference_Axes = "<size(s)=3> 1,000000 1,000000 308,000000"
|
|
|
POS_Limits_Axis1 = "<size(s)=2> 0 155"
|
|
|
POS_Limits_Axis2 = "<size(s)=2> 0 242"
|
|
|
POS_Limits_Axis3 = "<size(s)=2> 0 111"
|
|
|
POS_AxesFlipped.<size(s)> = "3"
|
|
|
POS_AxesFlipped 0 = "True"
|
|
|
POS_AxesFlipped 1 = "True"
|
|
|
POS_AxesFlipped 2 = "False"
|
|
|
Pos_MaxVelocity = "300"
|
|
|
Pos_MaxAcceleration = "15000"
|
|
|
Pos_MaxJerk = "140000"
|
|
|
Pos_DO_E-Stop_Index = "0"
|
|
|
Pos_DO_Setup_Index = "2"
|
|
|
ForceLimit_Axis3 = "<size(s)=1> 0,000000"
|
|
|
ForceLimit_Axis3_Text.<size(s)> = "1"
|
|
|
ForceLimit_Axis3_Text 0 = ""
|
|
|
ForceLimit_Axis3_AO_Limits = "<size(s)=2> 0,000000 100,000000"
|
|
|
ForceLimit_AI_Index = "0"
|
|
|
AirCooling_AI_Index = "1"
|
|
|
|
|
|
[DefaultValues]
|
|
|
WorkingStroke = "0"
|
|
|
MaxTemperature = "<size(s)=15> 50,000000 250,000000 250,000000 250,000000 250,000000 250,000000 250,000000 250,000000 250,000000 250,000000 250,000000 250,000000 250,000000 250,000000 250,000000"
|
|
|
MeasurementTime = "1"
|
|
|
NominalCurrent = "0"
|
|
|
TableControl = False
|
|
|
SensorsColor = "<size(s)=15> 16776960 16711680 16744448 16744640 16711935 10879142 8388863 8421631 423327 9567230 14869218 14869218 14869218 14869218 14869218"
|
|
|
Sensors+.<size(s)> = "15"
|
|
|
Sensors+ 0 = "True"
|
|
|
Sensors+ 1 = "True"
|
|
|
Sensors+ 2 = "True"
|
|
|
Sensors+ 3 = "True"
|
|
|
Sensors+ 4 = "False"
|
|
|
Sensors+ 5 = "False"
|
|
|
Sensors+ 6 = "False"
|
|
|
Sensors+ 7 = "False"
|
|
|
Sensors+ 8 = "False"
|
|
|
Sensors+ 9 = "False"
|
|
|
Sensors+ 10 = "False"
|
|
|
Sensors+ 11 = "False"
|
|
|
Sensors+ 12 = "False"
|
|
|
Sensors+ 13 = "False"
|
|
|
Sensors+ 14 = "False"
|
|
|
SensorsFunction.<size(s)> = "15"
|
|
|
SensorsFunction 0 = "Umgebungstemperatur"
|
|
|
SensorsFunction 1 = "Pr�flingstemperatur"
|
|
|
SensorsFunction 2 = "Temperatur 3"
|
|
|
SensorsFunction 3 = "Temperatur 4"
|
|
|
SensorsFunction 4 = "Temperatur 5"
|
|
|
SensorsFunction 5 = "Temperatur 6"
|
|
|
SensorsFunction 6 = "Temperatur 7"
|
|
|
SensorsFunction 7 = "Temperatur 8"
|
|
|
SensorsFunction 8 = "Temperatur 9"
|
|
|
SensorsFunction 9 = "Temperatur 10"
|
|
|
SensorsFunction 10 = "Temperatur 11"
|
|
|
SensorsFunction 11 = "Temperatur 12"
|
|
|
SensorsFunction 12 = "Temperatur 13"
|
|
|
SensorsFunction 13 = "Temperatur 14"
|
|
|
SensorsFunction 14 = "Temperatur 15"
|
|
|
ForceLimit_Z = "0"
|
|
|
MovingParameter.Velocity = "20,000000"
|
|
|
MovingParameter.Acceleration = "50,000000"
|
|
|
MovingParameter.Jerk = "140000,000000"
|
|
|
Learning_Steps.X = "1,000000"
|
|
|
Learning_Steps.Y = "1,000000"
|
|
|
Learning_Steps.Z = "1,000000"
|
|
|
|
|
|
[Pathes]
|
|
|
User = "C:\Work\CurrentTester\support\User.txt"
|
|
|
ReportsFolder = "C:\Work\CurrentTester\support\ResultData_HSMP2"
|
|
|
ProtocolsFolder = "C:\Work\CurrentTester\support\ResultData_HSMP2\Protocols"
|
|
|
CurrentProfilesFolder = "C:\Work\CurrentTester\support\CurrentProfiles"
|
|
|
Applicants = "C:\Work\CurrentTester\support\Applicants.txt"
|
|
|
|
|
|
[Report]
|
|
|
FileNameFormat = "%s_TestResults.txt"
|
|
|
ReportNameFormat = "%s_TestReport_%s.xlsx"
|
|
|
ReportTemplate_German = "C:\Work\CurrentTester\support\ReportTemplates\TemplateGerman.xlsx"
|
|
|
ReportTemplate_English = "C:\Work\CurrentTester\support\ReportTemplates\TemplateEnglish.xlsx"
|
|
|
|
|
|
[Protocol]
|
|
|
ProtocolNameFormat = "%s_A%d_Report_%s.docx"
|
|
|
ProtocolTemplate_German = "C:\Work\CurrentTester\support\ReportTemplates\ProtocolTemplateGerman.dotx"
|
|
|
ProtocolTemplate_English = "C:\Work\CurrentTester\support\ReportTemplates\ProtocolTemplateEnglish.dotx"
|
|
|
ProtocolComment_German = "Alle Messungen sind mit einem galvanisch isoliertem Thermosensor Type K durchf�hrt worden.\0ADie Testergebnisse und Auswertungen beziehen sich ausschlie�lich auf die Muster, die zu diesem Test unter Laborbedingungen verwendet wurden und auf den verwendeten Testaufbau!"
|
|
|
ProtocolComment_English = "All measurements were carried out with a galvanically isolated Type K thermal sensors.\0AThe test results and evaluations refer exclusively to the samples that were used for this test under laboratory conditions and to the test setup used!"
|
|
|
ProtocolDataFolderName = "Bilder|Messungen"
|
|
|
|
|
|
[StateMessages]
|
|
|
Info.<size(s)> = "29"
|
|
|
Info 0 = "Aktivierter Not-Halt oder eine T�r steht offen! Ein Teststart ist nicht m�glich"
|
|
|
Info 1 = "Zum Anlegen eines neuen Tests "Neuer Test" klicken"
|
|
|
Info 2 = "Grunddaten anlegen oder bestehenden Test �ffnen"
|
|
|
Info 3 = "Testdaten anlegen"
|
|
|
Info 4 = "Der Schl�sselschalter muss in die Position "Automatik" gebracht werden und die automatische Achsensteuerung soll aktiviert werden um den Test starten zu k�nnen oder den Strom manuell einzustellen!"
|
|
|
Info 5 = "Test geladen"
|
|
|
Info 6 = "Laufende Pr�fung..."
|
|
|
Info 7 = "Pr�fung erfolgreich abgeschlossen"
|
|
|
Info 8 = "Fehler aufgetreten!"
|
|
|
Info 9 = "Test abgebrochen!"
|
|
|
Info 10 = "Test abgebrochen! Maximale Temperatur wurde �berschritten"
|
|
|
Info 11 = "Test abgebrochen! Fehlerhafte Kontaktierung"
|
|
|
Info 12 = "Test abgebrochen! Messrate ist zu hoch"
|
|
|
Info 13 = "Test abgebrochen! Stromprofil- Generierung ist fehlgeschlagen"
|
|
|
Info 14 = "Test abgebrochen! Eingestellte Abschaltleistung der Stromquelle wurde erreicht"
|
|
|
Info 15 = "Test abgebrochen! Gemessener Strom liegt au�erhalb des definierten Bereichs"
|
|
|
Info 16 = "Testprotokoll wird erstellt... Bitte warten"
|
|
|
Info 17 = "Testprotokoll erstellt"
|
|
|
Info 18 = "Der letzte Test ist geladen..."
|
|
|
Info 19 = "Testdaten zur Testberichterstellung laden und ausw�hlen"
|
|
|
Info 20 = "Testbericht wird erstellt... Bitte warten"
|
|
|
Info 21 = "Testbericht erstellt"
|
|
|
Info 22 = "Test ist gespeichert"
|
|
|
Info 23 = "Achsen werden initialisiert..."
|
|
|
Info 24 = "Referenzfahrt l�uft..."
|
|
|
Info 25 = "X-Achse wird referenziert..."
|
|
|
Info 26 = "Y-Achse wird referenziert..."
|
|
|
Info 27 = "Z-Achse wird referenziert..."
|
|
|
Info 28 = "Position wird angefahren..."
|
|
|
Result.<size(s)> = "29"
|
|
|
Result 0 = "Not-Halt"
|
|
|
Result 1 = ""
|
|
|
Result 2 = "Bereit"
|
|
|
Result 3 = "Bereit"
|
|
|
Result 4 = "Einrichtbetrieb"
|
|
|
Result 5 = "Bereit"
|
|
|
Result 6 = "Pr�fung l�uft"
|
|
|
Result 7 = "Pr�fung fertig"
|
|
|
Result 8 = "Fehler"
|
|
|
Result 9 = "Pr�fung Stop"
|
|
|
Result 10 = "Pr�fung Stop"
|
|
|
Result 11 = "Pr�fung Stop"
|
|
|
Result 12 = "Pr�fung Stop"
|
|
|
Result 13 = "Pr�fung Stop"
|
|
|
Result 14 = "Pr�fung Stop"
|
|
|
Result 15 = "Pr�fung Stop"
|
|
|
Result 16 = "Bereit"
|
|
|
Result 17 = "Bereit"
|
|
|
Result 18 = "Bereit"
|
|
|
Result 19 = "Bereit"
|
|
|
Result 20 = "Bereit"
|
|
|
Result 21 = "Bereit"
|
|
|
Result 22 = "Bereit"
|
|
|
Result 23 = ""
|
|
|
Result 24 = "Einrichtbetrieb"
|
|
|
Result 25 = "Einrichtbetrieb"
|
|
|
Result 26 = "Einrichtbetrieb"
|
|
|
Result 27 = "Einrichtbetrieb"
|
|
|
Result 28 = "Einrichtbetrieb"
|
|
|
|
|
|
[DialogMessages]
|
|
|
Messages.<size(s)> = "8"
|
|
|
Messages 0 = "Achtung Einrichtbetrieb!\0AM�gliche Gefahren:\0A-Klemmgefahr\0A-Hei�e Oberfl�chen\0A-Lichtbogen"
|
|
|
Messages 1 = "Bitte achten Sie darauf, dass die hellblau markierten Felder in der gew�hlten Sprache sind"
|
|
|
Messages 2 = "Geben Sie die f�r die Testberichterstellung erforderlichen Daten ein. Bitte achten Sie darauf, dass die hellblau markierten Felder in der gew�hlten Sprache sind"
|
|
|
Messages 3 = "\0A\0A\0ADas Stromprofil f�r die gew�hlte Datengruppe ist nicht identisch!\0ABitte die Datenreihe mit dem nicht passenden Stromprofil entfernen"
|
|
|
Messages 4 = "W�hlen Sie eine Testkonfigurationsdatei zum Laden aus"
|
|
|
Messages 5 = "W�hlen Sie einen Ordner aus, der die Testergebnisse zum Laden enth�lt"
|
|
|
Messages 6 = "W�hlen Sie einen ID-Ordner aus, der alle Testergebnisse zum Laden enth�lt"
|
|
|
Messages 7 = "Die Merkzetteldaten werden gel�scht!\0ABitte best�tigen Sie die Operation oder schlie�en Sie das Dialogfeld, um den Vorgang abzubrechen ..."
|