##// END OF EJS Templates
- HSMP2 ini: voltage set to 10V;...
LabVIEW -
r38:39
parent child Browse files
Show More
1 NO CONTENT: modified file
@@ -1,292 +1,292
1 1 [Tester]
2 2 TesterType = "HSMP2"
3 3 TesterName = "Hochstrommessplatz 2"
4 4 MaxCurrent = 2000
5 5 MaxTemperature = 250
6 6 SensorsEnable.<size(s)> = "10"
7 7 SensorsEnable 0 = "True"
8 8 SensorsEnable 1 = "True"
9 9 SensorsEnable 2 = "True"
10 10 SensorsEnable 3 = "True"
11 11 SensorsEnable 4 = "True"
12 12 SensorsEnable 5 = "True"
13 13 SensorsEnable 6 = "True"
14 14 SensorsEnable 7 = "False"
15 15 SensorsEnable 8 = "False"
16 16 SensorsEnable 9 = "False"
17 17 SensorsDescription.<size(s)> = "10"
18 18 SensorsDescription 0 = "NI-9212: Ch1"
19 19 SensorsDescription 1 = "NI-9212: Ch2"
20 20 SensorsDescription 2 = "NI-9212: Ch3"
21 21 SensorsDescription 3 = "NI-9212: Ch4"
22 22 SensorsDescription 4 = "NI-9219: Ch1"
23 23 SensorsDescription 5 = "NI-9219: Ch2"
24 24 SensorsDescription 6 = "NI-9219: Ch3"
25 25 SensorsDescription 7 = "NI-9219: Ch4"
26 26 SensorsDescription 8 = ""
27 27 SensorsDescription 9 = ""
28 28 VoltageDescription.<size(s)> = "4 2"
29 29 VoltageDescription 0 = "NI-9215: Ch1"
30 30 VoltageDescription 1 = "Pr�flingsspannung [V]"
31 31 VoltageDescription 2 = "NI-9215: Ch2"
32 32 VoltageDescription 3 = "Zero Flux- Spannung [V]"
33 33 VoltageDescription 4 = ""
34 34 VoltageDescription 5 = "Strom [A]"
35 35 VoltageDescription 6 = ""
36 36 VoltageDescription 7 = "Widerstand [mOhm]"
37 37 CalibrationPassword = "48c8947f69c054a5caa934674ce8881d02bb18fb59d5a63eeaddff735b0e9801e87294783281ae49fc8287a0fd86779b27d7972d3e84f0fa0d826d7cb67dfefc"
38 38
39 39 [Hardware]
40 40 SimulateDevices = True
41 41 DI_E-Stop = ""
42 42 DI_Setup = ""
43 43 PowerSupply_VISAName = "COM4"
44 44 PowerSupply_Address = "0"
45 45 PowerSupply_Baudrate = "9600"
46 PowerSupply_OutputVoltage = "20,000000"
47 PowerSupply_OverVoltageProtection = "19,800000"
46 PowerSupply_OutputVoltage = "10,000000"
47 PowerSupply_OverVoltageProtection = "9,800000"
48 48 PowerSupply_MinCurrent = "0"
49 49 PowerSupply_Check = False
50 50 PowerSupply_WarningPower = "18000,000000"
51 51 PowerSupply_AbortPower = "20000,000000"
52 52 PowerSupply_PID = "FALSE"
53 53 PowerSupply_PID_Time = "0,100000"
54 54 PowerSupply_PID_ProportionalGain = "0,100000"
55 55 PowerSupply_PID_IntegralTime = "0,180000"
56 56 PowerSupply_PID_DerivativeTime = "0,000000"
57 57 AbortCurrentDifference = "0,000000"
58 58 Measurement_Channels.<size(s)> = "13"
59 59 Measurement_Channels 0 = "NI9215/ai0"
60 60 Measurement_Channels 1 = "NI9215/ai1"
61 61 Measurement_Channels 2 = "NI9212/ai0"
62 62 Measurement_Channels 3 = "NI9212/ai1"
63 63 Measurement_Channels 4 = "NI9212/ai2"
64 64 Measurement_Channels 5 = "NI9212/ai3"
65 65 Measurement_Channels 6 = "NI9219/ai0"
66 66 Measurement_Channels 7 = "NI9219/ai1"
67 67 Measurement_Channels 8 = "NI9219/ai2"
68 68 Measurement_Channels 9 = ""
69 69 Measurement_Channels 10 = ""
70 70 Measurement_Channels 11 = ""
71 71 Measurement_Channels 12 = ""
72 72 ShuntResistance = "0,005"
73 73 Measurement_Check = False
74 74 DMM_VISAName = "NI9219/ai3"
75 75 DMM_ContactLimits = "<size(s)=2> 0,000000 10,000000"
76 76 TemperatureGain = "<size(s)=10> 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000"
77 77 TemperatureOffset = "<size(s)=10> 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000"
78 78 VoltageGain = "<size(s)=4> 1,000000 1,000000 1,000000 1,000000"
79 79 VoltageOffset = "<size(s)=4> 0,000000 0,000000 0,000000 0,000000"
80 80 AllowedContactFails = "2"
81 81
82 82 [HSMP2]
83 83 DMM_Configuration.Maximum = "10,000000"
84 84 DMM_Configuration.Minimum = "-10,000000"
85 85 DMM_Configuration.Configuration = "2-Wire"
86 86 DMM_Configuration.CurrentExcitationSource = "Internal"
87 87 DMM_Configuration.CurrentExcitationValue = "0,000100"
88 88 Configuration_AI_Voltage.<size(s)> = "2"
89 89 Configuration_AI_Voltage 0.Maximum = "10,000000"
90 90 Configuration_AI_Voltage 0.Minimum = "-10,000000"
91 91 Configuration_AI_Voltage 0.InputTerminalConfiguration = "Differential"
92 92 Configuration_AI_Voltage 1.Maximum = "10,000000"
93 93 Configuration_AI_Voltage 1.Minimum = "0,000000"
94 94 Configuration_AI_Voltage 1.InputTerminalConfiguration = "Differential"
95 95 Configuration_AI_Thermocouple.<size(s)> = "10"
96 96 Configuration_AI_Thermocouple 0.Maximum = "250,000000"
97 97 Configuration_AI_Thermocouple 0.Minimum = "-200,000000"
98 98 Configuration_AI_Thermocouple 0.Type = "K"
99 99 Configuration_AI_Thermocouple 0.CJC_Source = "Built-In"
100 100 Configuration_AI_Thermocouple 0.CJC_Value = "25,000000"
101 101 Configuration_AI_Thermocouple 1.Maximum = "250,000000"
102 102 Configuration_AI_Thermocouple 1.Minimum = "-200,000000"
103 103 Configuration_AI_Thermocouple 1.Type = "K"
104 104 Configuration_AI_Thermocouple 1.CJC_Source = "Built-In"
105 105 Configuration_AI_Thermocouple 1.CJC_Value = "25,000000"
106 106 Configuration_AI_Thermocouple 2.Maximum = "250,000000"
107 107 Configuration_AI_Thermocouple 2.Minimum = "-200,000000"
108 108 Configuration_AI_Thermocouple 2.Type = "K"
109 109 Configuration_AI_Thermocouple 2.CJC_Source = "Built-In"
110 110 Configuration_AI_Thermocouple 2.CJC_Value = "25,000000"
111 111 Configuration_AI_Thermocouple 3.Maximum = "250,000000"
112 112 Configuration_AI_Thermocouple 3.Minimum = "-200,000000"
113 113 Configuration_AI_Thermocouple 3.Type = "K"
114 114 Configuration_AI_Thermocouple 3.CJC_Source = "Built-In"
115 115 Configuration_AI_Thermocouple 3.CJC_Value = "10,000000"
116 116 Configuration_AI_Thermocouple 4.Maximum = "250,000000"
117 117 Configuration_AI_Thermocouple 4.Minimum = "-200,000000"
118 118 Configuration_AI_Thermocouple 4.Type = "K"
119 119 Configuration_AI_Thermocouple 4.CJC_Source = "Built-In"
120 120 Configuration_AI_Thermocouple 4.CJC_Value = "25,000000"
121 121 Configuration_AI_Thermocouple 5.Maximum = "250,000000"
122 122 Configuration_AI_Thermocouple 5.Minimum = "-200,000000"
123 123 Configuration_AI_Thermocouple 5.Type = "K"
124 124 Configuration_AI_Thermocouple 5.CJC_Source = "Built-In"
125 125 Configuration_AI_Thermocouple 5.CJC_Value = "25,000000"
126 126 Configuration_AI_Thermocouple 6.Maximum = "250,000000"
127 127 Configuration_AI_Thermocouple 6.Minimum = "-200,000000"
128 128 Configuration_AI_Thermocouple 6.Type = "K"
129 129 Configuration_AI_Thermocouple 6.CJC_Source = "Built-In"
130 130 Configuration_AI_Thermocouple 6.CJC_Value = "25,000000"
131 131 Configuration_AI_Thermocouple 7.Maximum = "250,000000"
132 132 Configuration_AI_Thermocouple 7.Minimum = "-200,000000"
133 133 Configuration_AI_Thermocouple 7.Type = "K"
134 134 Configuration_AI_Thermocouple 7.CJC_Source = "Built-In"
135 135 Configuration_AI_Thermocouple 7.CJC_Value = "25,000000"
136 136 Configuration_AI_Thermocouple 8.Maximum = "250,000000"
137 137 Configuration_AI_Thermocouple 8.Minimum = "-200,000000"
138 138 Configuration_AI_Thermocouple 8.Type = "K"
139 139 Configuration_AI_Thermocouple 8.CJC_Source = "Built-In"
140 140 Configuration_AI_Thermocouple 8.CJC_Value = "25,000000"
141 141 Configuration_AI_Thermocouple 9.Maximum = "250,000000"
142 142 Configuration_AI_Thermocouple 9.Minimum = "-200,000000"
143 143 Configuration_AI_Thermocouple 9.Type = "K"
144 144 Configuration_AI_Thermocouple 9.CJC_Source = "Built-In"
145 145 Configuration_AI_Thermocouple 9.CJC_Value = "25,000000"
146 146 Configuration_AI_NI9219_Resistance.<size(s)> = "4"
147 147 Configuration_AI_NI9219_Resistance 0.Maximum = "10500,000000"
148 148 Configuration_AI_NI9219_Resistance 0.Minimum = "0,000000"
149 149 Configuration_AI_NI9219_Resistance 0.Configuration = "2-Wire"
150 150 Configuration_AI_NI9219_Resistance 0.CurrentExcitationSource = "Internal"
151 151 Configuration_AI_NI9219_Resistance 0.CurrentExcitationValue = "0,000500"
152 152 Configuration_AI_NI9219_Resistance 0.RTD_Type = "Pt3750"
153 153 Configuration_AI_NI9219_Resistance 0.R0 = "1000,000000"
154 154 Configuration_AI_NI9219_Resistance 0.ABC = "<size(s)=3> 1,224312924E-3 2,308955523E-4 3,938074268E-9"
155 155 Configuration_AI_NI9219_Resistance 1.Maximum = "250,000000"
156 156 Configuration_AI_NI9219_Resistance 1.Minimum = "-200,000000"
157 157 Configuration_AI_NI9219_Resistance 1.Configuration = "2-Wire"
158 158 Configuration_AI_NI9219_Resistance 1.CurrentExcitationSource = "Internal"
159 159 Configuration_AI_NI9219_Resistance 1.CurrentExcitationValue = "0,000500"
160 160 Configuration_AI_NI9219_Resistance 1.RTD_Type = "Pt3750"
161 161 Configuration_AI_NI9219_Resistance 1.R0 = "1000,000000"
162 162 Configuration_AI_NI9219_Resistance 1.ABC = "<size(s)=3> 1,224312924E-3 2,308955523E-4 3,938074268E-9"
163 163 Configuration_AI_NI9219_Resistance 2.Maximum = "250,000000"
164 164 Configuration_AI_NI9219_Resistance 2.Minimum = "-200,000000"
165 165 Configuration_AI_NI9219_Resistance 2.Configuration = "2-Wire"
166 166 Configuration_AI_NI9219_Resistance 2.CurrentExcitationSource = "Internal"
167 167 Configuration_AI_NI9219_Resistance 2.CurrentExcitationValue = "0,000500"
168 168 Configuration_AI_NI9219_Resistance 2.RTD_Type = "Pt3750"
169 169 Configuration_AI_NI9219_Resistance 2.R0 = "1000,000000"
170 170 Configuration_AI_NI9219_Resistance 2.ABC = "<size(s)=3> 3,81E-3 -6,02E-7 -6E-12"
171 171 Configuration_AI_NI9219_Resistance 3.Maximum = "250,000000"
172 172 Configuration_AI_NI9219_Resistance 3.Minimum = "-200,000000"
173 173 Configuration_AI_NI9219_Resistance 3.Configuration = "2-Wire"
174 174 Configuration_AI_NI9219_Resistance 3.CurrentExcitationSource = "Internal"
175 175 Configuration_AI_NI9219_Resistance 3.CurrentExcitationValue = "0,000500"
176 176 Configuration_AI_NI9219_Resistance 3.RTD_Type = "Pt3750"
177 177 Configuration_AI_NI9219_Resistance 3.R0 = "1000,000000"
178 178 Configuration_AI_NI9219_Resistance 3.ABC = "<size(s)=3> 1,224312924E-3 2,308955523E-4 3,938074268E-9"
179 179 Configuration_AI_NI9219_Type.<size(s)> = "4"
180 180 Configuration_AI_NI9219_Type 0 = "Thermocouple"
181 181 Configuration_AI_NI9219_Type 1 = "Thermocouple"
182 182 Configuration_AI_NI9219_Type 2 = "Resistance_RTD"
183 183 Configuration_AI_NI9219_Type 3 = "Thermocouple"
184 184
185 185 [DefaultValues]
186 186 WorkingStroke = "0"
187 187 MaxTemperature = "<size(s)=10> 50,000000 250,000000 250,000000 250,000000 250,000000 250,000000 250,000000 250,000000 250,000000 250,000000"
188 188 MeasurementTime = "1"
189 189 NominalCurrent = "0"
190 190 TableControl = False
191 191 SensorsColor = "<size(s)=10> 16776960 16711680 16744448 16744640 16711935 10879142 8388863 8421631 423327 9567230"
192 192 Sensors+.<size(s)> = "10"
193 193 Sensors+ 0 = "True"
194 194 Sensors+ 1 = "True"
195 195 Sensors+ 2 = "True"
196 196 Sensors+ 3 = "True"
197 197 Sensors+ 4 = "True"
198 198 Sensors+ 5 = "False"
199 199 Sensors+ 6 = "False"
200 200 Sensors+ 7 = "False"
201 201 Sensors+ 8 = "False"
202 202 Sensors+ 9 = "False"
203 203 SensorsFunction.<size(s)> = "10"
204 204 SensorsFunction 0 = "Umgebungstemperatur"
205 205 SensorsFunction 1 = "Pr�flingstemperatur"
206 206 SensorsFunction 2 = "Temperatur 3"
207 207 SensorsFunction 3 = "Temperatur 4"
208 208 SensorsFunction 4 = "Temperatur 5"
209 209 SensorsFunction 5 = "Temperatur 6"
210 210 SensorsFunction 6 = "Temperatur 7"
211 211 SensorsFunction 7 = "Temperatur 8"
212 212 SensorsFunction 8 = "Temperatur 9"
213 213 SensorsFunction 9 = "Temperatur 10"
214 214
215 215 [Pathes]
216 216 User = "C:\Work\CurrentTester\support\User.txt"
217 217 ReportsFolder = "C:\Work\CurrentTester\support\ResultData_HSMP2"
218 218 ProtocolsFolder = "C:\Work\CurrentTester\support\ResultData_HSMP2\Protocols"
219 219 CurrentProfilesFolder = "C:\Work\CurrentTester\support\CurrentProfiles"
220 220 Applicants = "C:\Work\CurrentTester\support\Applicants.txt"
221 221
222 222 [Report]
223 223 FileNameFormat = "%s_TestResults.txt"
224 224 ReportNameFormat = "%s_TestReport_%s.xlsx"
225 225 ReportTemplate_German = "C:\Work\CurrentTester\support\ReportTemplates\TemplateGerman.xlsx"
226 226 ReportTemplate_English = "C:\Work\CurrentTester\support\ReportTemplates\TemplateEnglish.xlsx"
227 227
228 228 [Protocol]
229 229 ProtocolNameFormat = "%s_A%d_Report_%s.docx"
230 230 ProtocolTemplate_German = "C:\Work\CurrentTester\support\ReportTemplates\ProtocolTemplateGerman.dotx"
231 231 ProtocolTemplate_English = "C:\Work\CurrentTester\support\ReportTemplates\ProtocolTemplateEnglish.dotx"
232 232 ProtocolComment_German = "Alle Messungen sind mit einem galvanisch isoliertem Thermosensor Type K durchf�hrt worden.\0ADie Testergebnisse und Auswertungen beziehen sich ausschlie�lich auf die Muster, die zu diesem Test unter Laborbedingungen verwendet wurden und auf den verwendeten Testaufbau!"
233 233 ProtocolComment_English = "All measurements were carried out with a galvanically isolated Type K thermal sensors.\0AThe test results and evaluations refer exclusively to the samples that were used for this test under laboratory conditions and to the test setup used!"
234 234 ProtocolDataFolderName = "Bilder|Messungen"
235 235
236 236 [StateMessages]
237 237 Info.<size(s)> = "22"
238 238 Info 0 = "Aktivierter Not-Halt oder eine T�r steht offen! Ein Teststart ist nicht m�glich"
239 239 Info 1 = "Zum Anlegen eines neuen Tests "Neuer Test" klicken"
240 240 Info 2 = "Grunddaten anlegen oder bestehenden Test �ffnen"
241 241 Info 3 = "Testdaten anlegen"
242 242 Info 4 = "Der Schl�sselschalter muss in die Position "Einrichten" gebracht werden um die Einrichtbuttons zu aktivieren oder in die Position "Automatik" um den Test starten zu k�nnen oder den Strom manuell einzustellen!"
243 243 Info 5 = "Test geladen"
244 244 Info 6 = "Laufende Pr�fung..."
245 245 Info 7 = "Pr�fung erfolgreich abgeschlossen"
246 246 Info 8 = "Fehler aufgetreten!"
247 247 Info 9 = "Test abgebrochen!"
248 248 Info 10 = "Test abgebrochen! Maximale Temperatur wurde �berschritten"
249 249 Info 11 = "Test abgebrochen! Fehlerhafte Kontaktierung"
250 250 Info 12 = "Test abgebrochen! Messrate ist zu hoch"
251 251 Info 13 = "Test abgebrochen! Stromprofil- Generierung ist fehlgeschlagen"
252 252 Info 14 = "Test abgebrochen! Eingestellte Abschaltleistung der Stromquelle wurde erreicht"
253 253 Info 15 = "Test abgebrochen! Gemessener Strom liegt au�erhalb des definierten Bereichs"
254 254 Info 16 = "Testprotokoll wird erstellt... Bitte warten"
255 255 Info 17 = "Testprotokoll erstellt"
256 256 Info 18 = "Der letzte Test ist geladen..."
257 257 Info 19 = "Testdaten zur Testberichterstellung laden und ausw�hlen"
258 258 Info 20 = "Testbericht wird erstellt... Bitte warten"
259 259 Info 21 = "Testbericht erstellt"
260 260 Result.<size(s)> = "22"
261 261 Result 0 = "Not-Halt"
262 262 Result 1 = ""
263 263 Result 2 = "Bereit"
264 264 Result 3 = "Bereit"
265 265 Result 4 = "Einrichtbetrieb"
266 266 Result 5 = "Bereit"
267 267 Result 6 = "Pr�fung l�uft"
268 268 Result 7 = "Pr�fung fertig"
269 269 Result 8 = "Fehler"
270 270 Result 9 = "Pr�fung Stop"
271 271 Result 10 = "Pr�fung Stop"
272 272 Result 11 = "Pr�fung Stop"
273 273 Result 12 = "Pr�fung Stop"
274 274 Result 13 = "Pr�fung Stop"
275 275 Result 14 = "Pr�fung Stop"
276 276 Result 15 = "Pr�fung Stop"
277 277 Result 16 = "Bereit"
278 278 Result 17 = "Bereit"
279 279 Result 18 = "Bereit"
280 280 Result 19 = "Bereit"
281 281 Result 20 = "Bereit"
282 282 Result 21 = "Bereit"
283 283
284 284 [DialogMessages]
285 285 Messages.<size(s)> = "7"
286 286 Messages 0 = "Achtung Einrichtbetrieb!\0AM�gliche Gefahren:\0A-Klemmgefahr\0A-Hei�e Oberfl�chen\0A-Lichtbogen"
287 287 Messages 1 = "Bitte achten Sie darauf, dass die hellblau markierten Felder in der gew�hlten Sprache sind"
288 288 Messages 2 = "Geben Sie die f�r die Testberichterstellung erforderlichen Daten ein. Bitte achten Sie darauf, dass die hellblau markierten Felder in der gew�hlten Sprache sind"
289 289 Messages 3 = "\0A\0A\0ADas Stromprofil f�r die gew�hlte Datengruppe ist nicht identisch!\0ABitte die Datenreihe mit dem nicht passenden Stromprofil entfernen"
290 290 Messages 4 = "W�hlen Sie eine Testkonfigurationsdatei zum Laden aus"
291 291 Messages 5 = "W�hlen Sie einen Ordner aus, der die Testergebnisse zum Laden enth�lt"
292 292 Messages 6 = "W�hlen Sie einen ID-Ordner aus, der alle Testergebnisse zum Laden enth�lt" No newline at end of file
@@ -1,292 +1,292
1 1 [Tester]
2 2 TesterType = "HSMP2"
3 3 TesterName = "Hochstrommessplatz 2"
4 4 MaxCurrent = 2000
5 5 MaxTemperature = 250
6 6 SensorsEnable.<size(s)> = "10"
7 7 SensorsEnable 0 = "True"
8 8 SensorsEnable 1 = "True"
9 9 SensorsEnable 2 = "True"
10 10 SensorsEnable 3 = "True"
11 11 SensorsEnable 4 = "True"
12 12 SensorsEnable 5 = "True"
13 13 SensorsEnable 6 = "True"
14 14 SensorsEnable 7 = "False"
15 15 SensorsEnable 8 = "False"
16 16 SensorsEnable 9 = "False"
17 17 SensorsDescription.<size(s)> = "10"
18 18 SensorsDescription 0 = "NI-9212: Ch1"
19 19 SensorsDescription 1 = "NI-9212: Ch2"
20 20 SensorsDescription 2 = "NI-9212: Ch3"
21 21 SensorsDescription 3 = "NI-9212: Ch4"
22 22 SensorsDescription 4 = "NI-9219: Ch1"
23 23 SensorsDescription 5 = "NI-9219: Ch2"
24 24 SensorsDescription 6 = "NI-9219: Ch3"
25 25 SensorsDescription 7 = "NI-9219: Ch4"
26 26 SensorsDescription 8 = ""
27 27 SensorsDescription 9 = ""
28 28 VoltageDescription.<size(s)> = "4 2"
29 29 VoltageDescription 0 = "NI-9215: Ch1"
30 30 VoltageDescription 1 = "Pr�flingsspannung [V]"
31 31 VoltageDescription 2 = "NI-9215: Ch2"
32 32 VoltageDescription 3 = "Zero Flux- Spannung [V]"
33 33 VoltageDescription 4 = ""
34 34 VoltageDescription 5 = "Strom [A]"
35 35 VoltageDescription 6 = ""
36 36 VoltageDescription 7 = "Widerstand [mOhm]"
37 37 CalibrationPassword = "48c8947f69c054a5caa934674ce8881d02bb18fb59d5a63eeaddff735b0e9801e87294783281ae49fc8287a0fd86779b27d7972d3e84f0fa0d826d7cb67dfefc"
38 38
39 39 [Hardware]
40 40 SimulateDevices = True
41 41 DI_E-Stop = ""
42 42 DI_Setup = ""
43 43 PowerSupply_VISAName = "COM4"
44 44 PowerSupply_Address = "0"
45 45 PowerSupply_Baudrate = "9600"
46 PowerSupply_OutputVoltage = "20,000000"
47 PowerSupply_OverVoltageProtection = "19,800000"
46 PowerSupply_OutputVoltage = "10,000000"
47 PowerSupply_OverVoltageProtection = "9,800000"
48 48 PowerSupply_MinCurrent = "0"
49 49 PowerSupply_Check = False
50 50 PowerSupply_WarningPower = "18000,000000"
51 51 PowerSupply_AbortPower = "20000,000000"
52 52 PowerSupply_PID = "FALSE"
53 53 PowerSupply_PID_Time = "0,100000"
54 54 PowerSupply_PID_ProportionalGain = "0,100000"
55 55 PowerSupply_PID_IntegralTime = "0,180000"
56 56 PowerSupply_PID_DerivativeTime = "0,000000"
57 57 AbortCurrentDifference = "0,000000"
58 58 Measurement_Channels.<size(s)> = "13"
59 59 Measurement_Channels 0 = "NI9215/ai0"
60 60 Measurement_Channels 1 = "NI9215/ai1"
61 61 Measurement_Channels 2 = "NI9212/ai0"
62 62 Measurement_Channels 3 = "NI9212/ai1"
63 63 Measurement_Channels 4 = "NI9212/ai2"
64 64 Measurement_Channels 5 = "NI9212/ai3"
65 65 Measurement_Channels 6 = "NI9219/ai0"
66 66 Measurement_Channels 7 = "NI9219/ai1"
67 67 Measurement_Channels 8 = "NI9219/ai2"
68 68 Measurement_Channels 9 = ""
69 69 Measurement_Channels 10 = ""
70 70 Measurement_Channels 11 = ""
71 71 Measurement_Channels 12 = ""
72 72 ShuntResistance = "0,005"
73 73 Measurement_Check = False
74 74 DMM_VISAName = "NI9219/ai3"
75 75 DMM_ContactLimits = "<size(s)=2> 0,000000 10,000000"
76 76 TemperatureGain = "<size(s)=10> 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000"
77 77 TemperatureOffset = "<size(s)=10> 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000"
78 78 VoltageGain = "<size(s)=4> 1,000000 1,000000 1,000000 1,000000"
79 79 VoltageOffset = "<size(s)=4> 0,000000 0,000000 0,000000 0,000000"
80 80 AllowedContactFails = "2"
81 81
82 82 [HSMP2]
83 83 DMM_Configuration.Maximum = "10,000000"
84 84 DMM_Configuration.Minimum = "-10,000000"
85 85 DMM_Configuration.Configuration = "2-Wire"
86 86 DMM_Configuration.CurrentExcitationSource = "Internal"
87 87 DMM_Configuration.CurrentExcitationValue = "0,000100"
88 88 Configuration_AI_Voltage.<size(s)> = "2"
89 89 Configuration_AI_Voltage 0.Maximum = "10,000000"
90 90 Configuration_AI_Voltage 0.Minimum = "-10,000000"
91 91 Configuration_AI_Voltage 0.InputTerminalConfiguration = "Differential"
92 92 Configuration_AI_Voltage 1.Maximum = "10,000000"
93 93 Configuration_AI_Voltage 1.Minimum = "0,000000"
94 94 Configuration_AI_Voltage 1.InputTerminalConfiguration = "Differential"
95 95 Configuration_AI_Thermocouple.<size(s)> = "10"
96 96 Configuration_AI_Thermocouple 0.Maximum = "250,000000"
97 97 Configuration_AI_Thermocouple 0.Minimum = "-200,000000"
98 98 Configuration_AI_Thermocouple 0.Type = "K"
99 99 Configuration_AI_Thermocouple 0.CJC_Source = "Built-In"
100 100 Configuration_AI_Thermocouple 0.CJC_Value = "25,000000"
101 101 Configuration_AI_Thermocouple 1.Maximum = "250,000000"
102 102 Configuration_AI_Thermocouple 1.Minimum = "-200,000000"
103 103 Configuration_AI_Thermocouple 1.Type = "K"
104 104 Configuration_AI_Thermocouple 1.CJC_Source = "Built-In"
105 105 Configuration_AI_Thermocouple 1.CJC_Value = "25,000000"
106 106 Configuration_AI_Thermocouple 2.Maximum = "250,000000"
107 107 Configuration_AI_Thermocouple 2.Minimum = "-200,000000"
108 108 Configuration_AI_Thermocouple 2.Type = "K"
109 109 Configuration_AI_Thermocouple 2.CJC_Source = "Built-In"
110 110 Configuration_AI_Thermocouple 2.CJC_Value = "25,000000"
111 111 Configuration_AI_Thermocouple 3.Maximum = "250,000000"
112 112 Configuration_AI_Thermocouple 3.Minimum = "-200,000000"
113 113 Configuration_AI_Thermocouple 3.Type = "K"
114 114 Configuration_AI_Thermocouple 3.CJC_Source = "Built-In"
115 115 Configuration_AI_Thermocouple 3.CJC_Value = "10,000000"
116 116 Configuration_AI_Thermocouple 4.Maximum = "250,000000"
117 117 Configuration_AI_Thermocouple 4.Minimum = "-200,000000"
118 118 Configuration_AI_Thermocouple 4.Type = "K"
119 119 Configuration_AI_Thermocouple 4.CJC_Source = "Built-In"
120 120 Configuration_AI_Thermocouple 4.CJC_Value = "25,000000"
121 121 Configuration_AI_Thermocouple 5.Maximum = "250,000000"
122 122 Configuration_AI_Thermocouple 5.Minimum = "-200,000000"
123 123 Configuration_AI_Thermocouple 5.Type = "K"
124 124 Configuration_AI_Thermocouple 5.CJC_Source = "Built-In"
125 125 Configuration_AI_Thermocouple 5.CJC_Value = "25,000000"
126 126 Configuration_AI_Thermocouple 6.Maximum = "250,000000"
127 127 Configuration_AI_Thermocouple 6.Minimum = "-200,000000"
128 128 Configuration_AI_Thermocouple 6.Type = "K"
129 129 Configuration_AI_Thermocouple 6.CJC_Source = "Built-In"
130 130 Configuration_AI_Thermocouple 6.CJC_Value = "25,000000"
131 131 Configuration_AI_Thermocouple 7.Maximum = "250,000000"
132 132 Configuration_AI_Thermocouple 7.Minimum = "-200,000000"
133 133 Configuration_AI_Thermocouple 7.Type = "K"
134 134 Configuration_AI_Thermocouple 7.CJC_Source = "Built-In"
135 135 Configuration_AI_Thermocouple 7.CJC_Value = "25,000000"
136 136 Configuration_AI_Thermocouple 8.Maximum = "250,000000"
137 137 Configuration_AI_Thermocouple 8.Minimum = "-200,000000"
138 138 Configuration_AI_Thermocouple 8.Type = "K"
139 139 Configuration_AI_Thermocouple 8.CJC_Source = "Built-In"
140 140 Configuration_AI_Thermocouple 8.CJC_Value = "25,000000"
141 141 Configuration_AI_Thermocouple 9.Maximum = "250,000000"
142 142 Configuration_AI_Thermocouple 9.Minimum = "-200,000000"
143 143 Configuration_AI_Thermocouple 9.Type = "K"
144 144 Configuration_AI_Thermocouple 9.CJC_Source = "Built-In"
145 145 Configuration_AI_Thermocouple 9.CJC_Value = "25,000000"
146 146 Configuration_AI_NI9219_Resistance.<size(s)> = "4"
147 147 Configuration_AI_NI9219_Resistance 0.Maximum = "10500,000000"
148 148 Configuration_AI_NI9219_Resistance 0.Minimum = "0,000000"
149 149 Configuration_AI_NI9219_Resistance 0.Configuration = "2-Wire"
150 150 Configuration_AI_NI9219_Resistance 0.CurrentExcitationSource = "Internal"
151 151 Configuration_AI_NI9219_Resistance 0.CurrentExcitationValue = "0,000500"
152 152 Configuration_AI_NI9219_Resistance 0.RTD_Type = "Pt3750"
153 153 Configuration_AI_NI9219_Resistance 0.R0 = "1000,000000"
154 154 Configuration_AI_NI9219_Resistance 0.ABC = "<size(s)=3> 1,224312924E-3 2,308955523E-4 3,938074268E-9"
155 155 Configuration_AI_NI9219_Resistance 1.Maximum = "250,000000"
156 156 Configuration_AI_NI9219_Resistance 1.Minimum = "-200,000000"
157 157 Configuration_AI_NI9219_Resistance 1.Configuration = "2-Wire"
158 158 Configuration_AI_NI9219_Resistance 1.CurrentExcitationSource = "Internal"
159 159 Configuration_AI_NI9219_Resistance 1.CurrentExcitationValue = "0,000500"
160 160 Configuration_AI_NI9219_Resistance 1.RTD_Type = "Pt3750"
161 161 Configuration_AI_NI9219_Resistance 1.R0 = "1000,000000"
162 162 Configuration_AI_NI9219_Resistance 1.ABC = "<size(s)=3> 1,224312924E-3 2,308955523E-4 3,938074268E-9"
163 163 Configuration_AI_NI9219_Resistance 2.Maximum = "250,000000"
164 164 Configuration_AI_NI9219_Resistance 2.Minimum = "-200,000000"
165 165 Configuration_AI_NI9219_Resistance 2.Configuration = "2-Wire"
166 166 Configuration_AI_NI9219_Resistance 2.CurrentExcitationSource = "Internal"
167 167 Configuration_AI_NI9219_Resistance 2.CurrentExcitationValue = "0,000500"
168 168 Configuration_AI_NI9219_Resistance 2.RTD_Type = "Pt3750"
169 169 Configuration_AI_NI9219_Resistance 2.R0 = "1000,000000"
170 170 Configuration_AI_NI9219_Resistance 2.ABC = "<size(s)=3> 3,81E-3 -6,02E-7 -6E-12"
171 171 Configuration_AI_NI9219_Resistance 3.Maximum = "250,000000"
172 172 Configuration_AI_NI9219_Resistance 3.Minimum = "-200,000000"
173 173 Configuration_AI_NI9219_Resistance 3.Configuration = "2-Wire"
174 174 Configuration_AI_NI9219_Resistance 3.CurrentExcitationSource = "Internal"
175 175 Configuration_AI_NI9219_Resistance 3.CurrentExcitationValue = "0,000500"
176 176 Configuration_AI_NI9219_Resistance 3.RTD_Type = "Pt3750"
177 177 Configuration_AI_NI9219_Resistance 3.R0 = "1000,000000"
178 178 Configuration_AI_NI9219_Resistance 3.ABC = "<size(s)=3> 1,224312924E-3 2,308955523E-4 3,938074268E-9"
179 179 Configuration_AI_NI9219_Type.<size(s)> = "4"
180 180 Configuration_AI_NI9219_Type 0 = "Thermocouple"
181 181 Configuration_AI_NI9219_Type 1 = "Thermocouple"
182 182 Configuration_AI_NI9219_Type 2 = "Resistance_RTD"
183 183 Configuration_AI_NI9219_Type 3 = "Thermocouple"
184 184
185 185 [DefaultValues]
186 186 WorkingStroke = "0"
187 187 MaxTemperature = "<size(s)=10> 50,000000 250,000000 250,000000 250,000000 250,000000 250,000000 250,000000 250,000000 250,000000 250,000000"
188 188 MeasurementTime = "1"
189 189 NominalCurrent = "0"
190 190 TableControl = False
191 191 SensorsColor = "<size(s)=10> 16776960 16711680 16744448 16744640 16711935 10879142 8388863 8421631 423327 9567230"
192 192 Sensors+.<size(s)> = "10"
193 193 Sensors+ 0 = "True"
194 194 Sensors+ 1 = "True"
195 195 Sensors+ 2 = "True"
196 196 Sensors+ 3 = "True"
197 197 Sensors+ 4 = "True"
198 198 Sensors+ 5 = "False"
199 199 Sensors+ 6 = "False"
200 200 Sensors+ 7 = "False"
201 201 Sensors+ 8 = "False"
202 202 Sensors+ 9 = "False"
203 203 SensorsFunction.<size(s)> = "10"
204 204 SensorsFunction 0 = "Umgebungstemperatur"
205 205 SensorsFunction 1 = "Pr�flingstemperatur"
206 206 SensorsFunction 2 = "Temperatur 3"
207 207 SensorsFunction 3 = "Temperatur 4"
208 208 SensorsFunction 4 = "Temperatur 5"
209 209 SensorsFunction 5 = "Temperatur 6"
210 210 SensorsFunction 6 = "Temperatur 7"
211 211 SensorsFunction 7 = "Temperatur 8"
212 212 SensorsFunction 8 = "Temperatur 9"
213 213 SensorsFunction 9 = "Temperatur 10"
214 214
215 215 [Pathes]
216 216 User = "C:\Work\CurrentTester\support\User.txt"
217 217 ReportsFolder = "C:\Work\CurrentTester\support\ResultData_HSMP2"
218 218 ProtocolsFolder = "C:\Work\CurrentTester\support\ResultData_HSMP2\Protocols"
219 219 CurrentProfilesFolder = "C:\Work\CurrentTester\support\CurrentProfiles"
220 220 Applicants = "C:\Work\CurrentTester\support\Applicants.txt"
221 221
222 222 [Report]
223 223 FileNameFormat = "%s_TestResults.txt"
224 224 ReportNameFormat = "%s_TestReport_%s.xlsx"
225 225 ReportTemplate_German = "C:\Work\CurrentTester\support\ReportTemplates\TemplateGerman.xlsx"
226 226 ReportTemplate_English = "C:\Work\CurrentTester\support\ReportTemplates\TemplateEnglish.xlsx"
227 227
228 228 [Protocol]
229 229 ProtocolNameFormat = "%s_A%d_Report_%s.docx"
230 230 ProtocolTemplate_German = "C:\Work\CurrentTester\support\ReportTemplates\ProtocolTemplateGerman.dotx"
231 231 ProtocolTemplate_English = "C:\Work\CurrentTester\support\ReportTemplates\ProtocolTemplateEnglish.dotx"
232 232 ProtocolComment_German = "Alle Messungen sind mit einem galvanisch isoliertem Thermosensor Type K durchf�hrt worden.\0ADie Testergebnisse und Auswertungen beziehen sich ausschlie�lich auf die Muster, die zu diesem Test unter Laborbedingungen verwendet wurden und auf den verwendeten Testaufbau!"
233 233 ProtocolComment_English = "All measurements were carried out with a galvanically isolated Type K thermal sensors.\0AThe test results and evaluations refer exclusively to the samples that were used for this test under laboratory conditions and to the test setup used!"
234 234 ProtocolDataFolderName = "Bilder|Messungen"
235 235
236 236 [StateMessages]
237 237 Info.<size(s)> = "22"
238 238 Info 0 = "Aktivierter Not-Halt oder eine T�r steht offen! Ein Teststart ist nicht m�glich"
239 239 Info 1 = "Zum Anlegen eines neuen Tests "Neuer Test" klicken"
240 240 Info 2 = "Grunddaten anlegen oder bestehenden Test �ffnen"
241 241 Info 3 = "Testdaten anlegen"
242 242 Info 4 = "Der Schl�sselschalter muss in die Position "Einrichten" gebracht werden um die Einrichtbuttons zu aktivieren oder in die Position "Automatik" um den Test starten zu k�nnen oder den Strom manuell einzustellen!"
243 243 Info 5 = "Test geladen"
244 244 Info 6 = "Laufende Pr�fung..."
245 245 Info 7 = "Pr�fung erfolgreich abgeschlossen"
246 246 Info 8 = "Fehler aufgetreten!"
247 247 Info 9 = "Test abgebrochen!"
248 248 Info 10 = "Test abgebrochen! Maximale Temperatur wurde �berschritten"
249 249 Info 11 = "Test abgebrochen! Fehlerhafte Kontaktierung"
250 250 Info 12 = "Test abgebrochen! Messrate ist zu hoch"
251 251 Info 13 = "Test abgebrochen! Stromprofil- Generierung ist fehlgeschlagen"
252 252 Info 14 = "Test abgebrochen! Eingestellte Abschaltleistung der Stromquelle wurde erreicht"
253 253 Info 15 = "Test abgebrochen! Gemessener Strom liegt au�erhalb des definierten Bereichs"
254 254 Info 16 = "Testprotokoll wird erstellt... Bitte warten"
255 255 Info 17 = "Testprotokoll erstellt"
256 256 Info 18 = "Der letzte Test ist geladen..."
257 257 Info 19 = "Testdaten zur Testberichterstellung laden und ausw�hlen"
258 258 Info 20 = "Testbericht wird erstellt... Bitte warten"
259 259 Info 21 = "Testbericht erstellt"
260 260 Result.<size(s)> = "22"
261 261 Result 0 = "Not-Halt"
262 262 Result 1 = ""
263 263 Result 2 = "Bereit"
264 264 Result 3 = "Bereit"
265 265 Result 4 = "Einrichtbetrieb"
266 266 Result 5 = "Bereit"
267 267 Result 6 = "Pr�fung l�uft"
268 268 Result 7 = "Pr�fung fertig"
269 269 Result 8 = "Fehler"
270 270 Result 9 = "Pr�fung Stop"
271 271 Result 10 = "Pr�fung Stop"
272 272 Result 11 = "Pr�fung Stop"
273 273 Result 12 = "Pr�fung Stop"
274 274 Result 13 = "Pr�fung Stop"
275 275 Result 14 = "Pr�fung Stop"
276 276 Result 15 = "Pr�fung Stop"
277 277 Result 16 = "Bereit"
278 278 Result 17 = "Bereit"
279 279 Result 18 = "Bereit"
280 280 Result 19 = "Bereit"
281 281 Result 20 = "Bereit"
282 282 Result 21 = "Bereit"
283 283
284 284 [DialogMessages]
285 285 Messages.<size(s)> = "7"
286 286 Messages 0 = "Achtung Einrichtbetrieb!\0AM�gliche Gefahren:\0A-Klemmgefahr\0A-Hei�e Oberfl�chen\0A-Lichtbogen"
287 287 Messages 1 = "Bitte achten Sie darauf, dass die hellblau markierten Felder in der gew�hlten Sprache sind"
288 288 Messages 2 = "Geben Sie die f�r die Testberichterstellung erforderlichen Daten ein. Bitte achten Sie darauf, dass die hellblau markierten Felder in der gew�hlten Sprache sind"
289 289 Messages 3 = "\0A\0A\0ADas Stromprofil f�r die gew�hlte Datengruppe ist nicht identisch!\0ABitte die Datenreihe mit dem nicht passenden Stromprofil entfernen"
290 290 Messages 4 = "W�hlen Sie eine Testkonfigurationsdatei zum Laden aus"
291 291 Messages 5 = "W�hlen Sie einen Ordner aus, der die Testergebnisse zum Laden enth�lt"
292 292 Messages 6 = "W�hlen Sie einen ID-Ordner aus, der alle Testergebnisse zum Laden enth�lt" No newline at end of file
1 NO CONTENT: modified file
General Comments 0
You need to be logged in to leave comments. Login now