1 | 1 | [Tester] |
|
2 | 2 | TesterType = "HSMP2" |
|
3 | 3 | TesterName = "Hochstrommessplatz 2" |
|
4 | 4 | MaxCurrent = 2000 |
|
5 | 5 | MaxTemperature = 250 |
|
6 | 6 | SensorsEnable.<size(s)> = "10" |
|
7 | 7 | SensorsEnable 0 = "True" |
|
8 | 8 | SensorsEnable 1 = "True" |
|
9 | 9 | SensorsEnable 2 = "True" |
|
10 | 10 | SensorsEnable 3 = "True" |
|
11 | 11 | SensorsEnable 4 = "True" |
|
12 | 12 | SensorsEnable 5 = "True" |
|
13 | 13 | SensorsEnable 6 = "True" |
|
14 | 14 | SensorsEnable 7 = "False" |
|
15 | 15 | SensorsEnable 8 = "False" |
|
16 | 16 | SensorsEnable 9 = "False" |
|
17 | 17 | SensorsDescription.<size(s)> = "10" |
|
18 | 18 | SensorsDescription 0 = "NI-9212: Ch1" |
|
19 | 19 | SensorsDescription 1 = "NI-9212: Ch2" |
|
20 | 20 | SensorsDescription 2 = "NI-9212: Ch3" |
|
21 | 21 | SensorsDescription 3 = "NI-9212: Ch4" |
|
22 | 22 | SensorsDescription 4 = "NI-9219: Ch1" |
|
23 | 23 | SensorsDescription 5 = "NI-9219: Ch2" |
|
24 | 24 | SensorsDescription 6 = "NI-9219: Ch3" |
|
25 | 25 | SensorsDescription 7 = "NI-9219: Ch4" |
|
26 | 26 | SensorsDescription 8 = "" |
|
27 | 27 | SensorsDescription 9 = "" |
|
28 | 28 | VoltageDescription.<size(s)> = "4 2" |
|
29 | 29 | VoltageDescription 0 = "NI-9215: Ch1" |
|
30 | 30 | VoltageDescription 1 = "Pr�flingsspannung [V]" |
|
31 | 31 | VoltageDescription 2 = "NI-9215: Ch2" |
|
32 | 32 | VoltageDescription 3 = "Zero Flux- Spannung [V]" |
|
33 | 33 | VoltageDescription 4 = "" |
|
34 | 34 | VoltageDescription 5 = "Strom [A]" |
|
35 | 35 | VoltageDescription 6 = "" |
|
36 | 36 | VoltageDescription 7 = "Widerstand [mOhm]" |
|
37 | 37 | CalibrationPassword = "48c8947f69c054a5caa934674ce8881d02bb18fb59d5a63eeaddff735b0e9801e87294783281ae49fc8287a0fd86779b27d7972d3e84f0fa0d826d7cb67dfefc" |
|
38 | 38 | |
|
39 | 39 | [Hardware] |
|
40 | 40 | SimulateDevices = True |
|
41 | 41 | DI_E-Stop = "" |
|
42 | 42 | DI_Setup = "" |
|
43 | 43 | PowerSupply_VISAName = "COM4" |
|
44 | 44 | PowerSupply_Address = "0" |
|
45 | 45 | PowerSupply_Baudrate = "9600" |
|
46 |
PowerSupply_OutputVoltage = " |
|
|
47 |
PowerSupply_OverVoltageProtection = " |
|
|
46 | PowerSupply_OutputVoltage = "10,000000" | |
|
47 | PowerSupply_OverVoltageProtection = "9,800000" | |
|
48 | 48 | PowerSupply_MinCurrent = "0" |
|
49 | 49 | PowerSupply_Check = False |
|
50 | 50 | PowerSupply_WarningPower = "18000,000000" |
|
51 | 51 | PowerSupply_AbortPower = "20000,000000" |
|
52 | 52 | PowerSupply_PID = "FALSE" |
|
53 | 53 | PowerSupply_PID_Time = "0,100000" |
|
54 | 54 | PowerSupply_PID_ProportionalGain = "0,100000" |
|
55 | 55 | PowerSupply_PID_IntegralTime = "0,180000" |
|
56 | 56 | PowerSupply_PID_DerivativeTime = "0,000000" |
|
57 | 57 | AbortCurrentDifference = "0,000000" |
|
58 | 58 | Measurement_Channels.<size(s)> = "13" |
|
59 | 59 | Measurement_Channels 0 = "NI9215/ai0" |
|
60 | 60 | Measurement_Channels 1 = "NI9215/ai1" |
|
61 | 61 | Measurement_Channels 2 = "NI9212/ai0" |
|
62 | 62 | Measurement_Channels 3 = "NI9212/ai1" |
|
63 | 63 | Measurement_Channels 4 = "NI9212/ai2" |
|
64 | 64 | Measurement_Channels 5 = "NI9212/ai3" |
|
65 | 65 | Measurement_Channels 6 = "NI9219/ai0" |
|
66 | 66 | Measurement_Channels 7 = "NI9219/ai1" |
|
67 | 67 | Measurement_Channels 8 = "NI9219/ai2" |
|
68 | 68 | Measurement_Channels 9 = "" |
|
69 | 69 | Measurement_Channels 10 = "" |
|
70 | 70 | Measurement_Channels 11 = "" |
|
71 | 71 | Measurement_Channels 12 = "" |
|
72 | 72 | ShuntResistance = "0,005" |
|
73 | 73 | Measurement_Check = False |
|
74 | 74 | DMM_VISAName = "NI9219/ai3" |
|
75 | 75 | DMM_ContactLimits = "<size(s)=2> 0,000000 10,000000" |
|
76 | 76 | TemperatureGain = "<size(s)=10> 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000" |
|
77 | 77 | TemperatureOffset = "<size(s)=10> 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000" |
|
78 | 78 | VoltageGain = "<size(s)=4> 1,000000 1,000000 1,000000 1,000000" |
|
79 | 79 | VoltageOffset = "<size(s)=4> 0,000000 0,000000 0,000000 0,000000" |
|
80 | 80 | AllowedContactFails = "2" |
|
81 | 81 | |
|
82 | 82 | [HSMP2] |
|
83 | 83 | DMM_Configuration.Maximum = "10,000000" |
|
84 | 84 | DMM_Configuration.Minimum = "-10,000000" |
|
85 | 85 | DMM_Configuration.Configuration = "2-Wire" |
|
86 | 86 | DMM_Configuration.CurrentExcitationSource = "Internal" |
|
87 | 87 | DMM_Configuration.CurrentExcitationValue = "0,000100" |
|
88 | 88 | Configuration_AI_Voltage.<size(s)> = "2" |
|
89 | 89 | Configuration_AI_Voltage 0.Maximum = "10,000000" |
|
90 | 90 | Configuration_AI_Voltage 0.Minimum = "-10,000000" |
|
91 | 91 | Configuration_AI_Voltage 0.InputTerminalConfiguration = "Differential" |
|
92 | 92 | Configuration_AI_Voltage 1.Maximum = "10,000000" |
|
93 | 93 | Configuration_AI_Voltage 1.Minimum = "0,000000" |
|
94 | 94 | Configuration_AI_Voltage 1.InputTerminalConfiguration = "Differential" |
|
95 | 95 | Configuration_AI_Thermocouple.<size(s)> = "10" |
|
96 | 96 | Configuration_AI_Thermocouple 0.Maximum = "250,000000" |
|
97 | 97 | Configuration_AI_Thermocouple 0.Minimum = "-200,000000" |
|
98 | 98 | Configuration_AI_Thermocouple 0.Type = "K" |
|
99 | 99 | Configuration_AI_Thermocouple 0.CJC_Source = "Built-In" |
|
100 | 100 | Configuration_AI_Thermocouple 0.CJC_Value = "25,000000" |
|
101 | 101 | Configuration_AI_Thermocouple 1.Maximum = "250,000000" |
|
102 | 102 | Configuration_AI_Thermocouple 1.Minimum = "-200,000000" |
|
103 | 103 | Configuration_AI_Thermocouple 1.Type = "K" |
|
104 | 104 | Configuration_AI_Thermocouple 1.CJC_Source = "Built-In" |
|
105 | 105 | Configuration_AI_Thermocouple 1.CJC_Value = "25,000000" |
|
106 | 106 | Configuration_AI_Thermocouple 2.Maximum = "250,000000" |
|
107 | 107 | Configuration_AI_Thermocouple 2.Minimum = "-200,000000" |
|
108 | 108 | Configuration_AI_Thermocouple 2.Type = "K" |
|
109 | 109 | Configuration_AI_Thermocouple 2.CJC_Source = "Built-In" |
|
110 | 110 | Configuration_AI_Thermocouple 2.CJC_Value = "25,000000" |
|
111 | 111 | Configuration_AI_Thermocouple 3.Maximum = "250,000000" |
|
112 | 112 | Configuration_AI_Thermocouple 3.Minimum = "-200,000000" |
|
113 | 113 | Configuration_AI_Thermocouple 3.Type = "K" |
|
114 | 114 | Configuration_AI_Thermocouple 3.CJC_Source = "Built-In" |
|
115 | 115 | Configuration_AI_Thermocouple 3.CJC_Value = "10,000000" |
|
116 | 116 | Configuration_AI_Thermocouple 4.Maximum = "250,000000" |
|
117 | 117 | Configuration_AI_Thermocouple 4.Minimum = "-200,000000" |
|
118 | 118 | Configuration_AI_Thermocouple 4.Type = "K" |
|
119 | 119 | Configuration_AI_Thermocouple 4.CJC_Source = "Built-In" |
|
120 | 120 | Configuration_AI_Thermocouple 4.CJC_Value = "25,000000" |
|
121 | 121 | Configuration_AI_Thermocouple 5.Maximum = "250,000000" |
|
122 | 122 | Configuration_AI_Thermocouple 5.Minimum = "-200,000000" |
|
123 | 123 | Configuration_AI_Thermocouple 5.Type = "K" |
|
124 | 124 | Configuration_AI_Thermocouple 5.CJC_Source = "Built-In" |
|
125 | 125 | Configuration_AI_Thermocouple 5.CJC_Value = "25,000000" |
|
126 | 126 | Configuration_AI_Thermocouple 6.Maximum = "250,000000" |
|
127 | 127 | Configuration_AI_Thermocouple 6.Minimum = "-200,000000" |
|
128 | 128 | Configuration_AI_Thermocouple 6.Type = "K" |
|
129 | 129 | Configuration_AI_Thermocouple 6.CJC_Source = "Built-In" |
|
130 | 130 | Configuration_AI_Thermocouple 6.CJC_Value = "25,000000" |
|
131 | 131 | Configuration_AI_Thermocouple 7.Maximum = "250,000000" |
|
132 | 132 | Configuration_AI_Thermocouple 7.Minimum = "-200,000000" |
|
133 | 133 | Configuration_AI_Thermocouple 7.Type = "K" |
|
134 | 134 | Configuration_AI_Thermocouple 7.CJC_Source = "Built-In" |
|
135 | 135 | Configuration_AI_Thermocouple 7.CJC_Value = "25,000000" |
|
136 | 136 | Configuration_AI_Thermocouple 8.Maximum = "250,000000" |
|
137 | 137 | Configuration_AI_Thermocouple 8.Minimum = "-200,000000" |
|
138 | 138 | Configuration_AI_Thermocouple 8.Type = "K" |
|
139 | 139 | Configuration_AI_Thermocouple 8.CJC_Source = "Built-In" |
|
140 | 140 | Configuration_AI_Thermocouple 8.CJC_Value = "25,000000" |
|
141 | 141 | Configuration_AI_Thermocouple 9.Maximum = "250,000000" |
|
142 | 142 | Configuration_AI_Thermocouple 9.Minimum = "-200,000000" |
|
143 | 143 | Configuration_AI_Thermocouple 9.Type = "K" |
|
144 | 144 | Configuration_AI_Thermocouple 9.CJC_Source = "Built-In" |
|
145 | 145 | Configuration_AI_Thermocouple 9.CJC_Value = "25,000000" |
|
146 | 146 | Configuration_AI_NI9219_Resistance.<size(s)> = "4" |
|
147 | 147 | Configuration_AI_NI9219_Resistance 0.Maximum = "10500,000000" |
|
148 | 148 | Configuration_AI_NI9219_Resistance 0.Minimum = "0,000000" |
|
149 | 149 | Configuration_AI_NI9219_Resistance 0.Configuration = "2-Wire" |
|
150 | 150 | Configuration_AI_NI9219_Resistance 0.CurrentExcitationSource = "Internal" |
|
151 | 151 | Configuration_AI_NI9219_Resistance 0.CurrentExcitationValue = "0,000500" |
|
152 | 152 | Configuration_AI_NI9219_Resistance 0.RTD_Type = "Pt3750" |
|
153 | 153 | Configuration_AI_NI9219_Resistance 0.R0 = "1000,000000" |
|
154 | 154 | Configuration_AI_NI9219_Resistance 0.ABC = "<size(s)=3> 1,224312924E-3 2,308955523E-4 3,938074268E-9" |
|
155 | 155 | Configuration_AI_NI9219_Resistance 1.Maximum = "250,000000" |
|
156 | 156 | Configuration_AI_NI9219_Resistance 1.Minimum = "-200,000000" |
|
157 | 157 | Configuration_AI_NI9219_Resistance 1.Configuration = "2-Wire" |
|
158 | 158 | Configuration_AI_NI9219_Resistance 1.CurrentExcitationSource = "Internal" |
|
159 | 159 | Configuration_AI_NI9219_Resistance 1.CurrentExcitationValue = "0,000500" |
|
160 | 160 | Configuration_AI_NI9219_Resistance 1.RTD_Type = "Pt3750" |
|
161 | 161 | Configuration_AI_NI9219_Resistance 1.R0 = "1000,000000" |
|
162 | 162 | Configuration_AI_NI9219_Resistance 1.ABC = "<size(s)=3> 1,224312924E-3 2,308955523E-4 3,938074268E-9" |
|
163 | 163 | Configuration_AI_NI9219_Resistance 2.Maximum = "250,000000" |
|
164 | 164 | Configuration_AI_NI9219_Resistance 2.Minimum = "-200,000000" |
|
165 | 165 | Configuration_AI_NI9219_Resistance 2.Configuration = "2-Wire" |
|
166 | 166 | Configuration_AI_NI9219_Resistance 2.CurrentExcitationSource = "Internal" |
|
167 | 167 | Configuration_AI_NI9219_Resistance 2.CurrentExcitationValue = "0,000500" |
|
168 | 168 | Configuration_AI_NI9219_Resistance 2.RTD_Type = "Pt3750" |
|
169 | 169 | Configuration_AI_NI9219_Resistance 2.R0 = "1000,000000" |
|
170 | 170 | Configuration_AI_NI9219_Resistance 2.ABC = "<size(s)=3> 3,81E-3 -6,02E-7 -6E-12" |
|
171 | 171 | Configuration_AI_NI9219_Resistance 3.Maximum = "250,000000" |
|
172 | 172 | Configuration_AI_NI9219_Resistance 3.Minimum = "-200,000000" |
|
173 | 173 | Configuration_AI_NI9219_Resistance 3.Configuration = "2-Wire" |
|
174 | 174 | Configuration_AI_NI9219_Resistance 3.CurrentExcitationSource = "Internal" |
|
175 | 175 | Configuration_AI_NI9219_Resistance 3.CurrentExcitationValue = "0,000500" |
|
176 | 176 | Configuration_AI_NI9219_Resistance 3.RTD_Type = "Pt3750" |
|
177 | 177 | Configuration_AI_NI9219_Resistance 3.R0 = "1000,000000" |
|
178 | 178 | Configuration_AI_NI9219_Resistance 3.ABC = "<size(s)=3> 1,224312924E-3 2,308955523E-4 3,938074268E-9" |
|
179 | 179 | Configuration_AI_NI9219_Type.<size(s)> = "4" |
|
180 | 180 | Configuration_AI_NI9219_Type 0 = "Thermocouple" |
|
181 | 181 | Configuration_AI_NI9219_Type 1 = "Thermocouple" |
|
182 | 182 | Configuration_AI_NI9219_Type 2 = "Resistance_RTD" |
|
183 | 183 | Configuration_AI_NI9219_Type 3 = "Thermocouple" |
|
184 | 184 | |
|
185 | 185 | [DefaultValues] |
|
186 | 186 | WorkingStroke = "0" |
|
187 | 187 | MaxTemperature = "<size(s)=10> 50,000000 250,000000 250,000000 250,000000 250,000000 250,000000 250,000000 250,000000 250,000000 250,000000" |
|
188 | 188 | MeasurementTime = "1" |
|
189 | 189 | NominalCurrent = "0" |
|
190 | 190 | TableControl = False |
|
191 | 191 | SensorsColor = "<size(s)=10> 16776960 16711680 16744448 16744640 16711935 10879142 8388863 8421631 423327 9567230" |
|
192 | 192 | Sensors+.<size(s)> = "10" |
|
193 | 193 | Sensors+ 0 = "True" |
|
194 | 194 | Sensors+ 1 = "True" |
|
195 | 195 | Sensors+ 2 = "True" |
|
196 | 196 | Sensors+ 3 = "True" |
|
197 | 197 | Sensors+ 4 = "True" |
|
198 | 198 | Sensors+ 5 = "False" |
|
199 | 199 | Sensors+ 6 = "False" |
|
200 | 200 | Sensors+ 7 = "False" |
|
201 | 201 | Sensors+ 8 = "False" |
|
202 | 202 | Sensors+ 9 = "False" |
|
203 | 203 | SensorsFunction.<size(s)> = "10" |
|
204 | 204 | SensorsFunction 0 = "Umgebungstemperatur" |
|
205 | 205 | SensorsFunction 1 = "Pr�flingstemperatur" |
|
206 | 206 | SensorsFunction 2 = "Temperatur 3" |
|
207 | 207 | SensorsFunction 3 = "Temperatur 4" |
|
208 | 208 | SensorsFunction 4 = "Temperatur 5" |
|
209 | 209 | SensorsFunction 5 = "Temperatur 6" |
|
210 | 210 | SensorsFunction 6 = "Temperatur 7" |
|
211 | 211 | SensorsFunction 7 = "Temperatur 8" |
|
212 | 212 | SensorsFunction 8 = "Temperatur 9" |
|
213 | 213 | SensorsFunction 9 = "Temperatur 10" |
|
214 | 214 | |
|
215 | 215 | [Pathes] |
|
216 | 216 | User = "C:\Work\CurrentTester\support\User.txt" |
|
217 | 217 | ReportsFolder = "C:\Work\CurrentTester\support\ResultData_HSMP2" |
|
218 | 218 | ProtocolsFolder = "C:\Work\CurrentTester\support\ResultData_HSMP2\Protocols" |
|
219 | 219 | CurrentProfilesFolder = "C:\Work\CurrentTester\support\CurrentProfiles" |
|
220 | 220 | Applicants = "C:\Work\CurrentTester\support\Applicants.txt" |
|
221 | 221 | |
|
222 | 222 | [Report] |
|
223 | 223 | FileNameFormat = "%s_TestResults.txt" |
|
224 | 224 | ReportNameFormat = "%s_TestReport_%s.xlsx" |
|
225 | 225 | ReportTemplate_German = "C:\Work\CurrentTester\support\ReportTemplates\TemplateGerman.xlsx" |
|
226 | 226 | ReportTemplate_English = "C:\Work\CurrentTester\support\ReportTemplates\TemplateEnglish.xlsx" |
|
227 | 227 | |
|
228 | 228 | [Protocol] |
|
229 | 229 | ProtocolNameFormat = "%s_A%d_Report_%s.docx" |
|
230 | 230 | ProtocolTemplate_German = "C:\Work\CurrentTester\support\ReportTemplates\ProtocolTemplateGerman.dotx" |
|
231 | 231 | ProtocolTemplate_English = "C:\Work\CurrentTester\support\ReportTemplates\ProtocolTemplateEnglish.dotx" |
|
232 | 232 | ProtocolComment_German = "Alle Messungen sind mit einem galvanisch isoliertem Thermosensor Type K durchf�hrt worden.\0ADie Testergebnisse und Auswertungen beziehen sich ausschlie�lich auf die Muster, die zu diesem Test unter Laborbedingungen verwendet wurden und auf den verwendeten Testaufbau!" |
|
233 | 233 | ProtocolComment_English = "All measurements were carried out with a galvanically isolated Type K thermal sensors.\0AThe test results and evaluations refer exclusively to the samples that were used for this test under laboratory conditions and to the test setup used!" |
|
234 | 234 | ProtocolDataFolderName = "Bilder|Messungen" |
|
235 | 235 | |
|
236 | 236 | [StateMessages] |
|
237 | 237 | Info.<size(s)> = "22" |
|
238 | 238 | Info 0 = "Aktivierter Not-Halt oder eine T�r steht offen! Ein Teststart ist nicht m�glich" |
|
239 | 239 | Info 1 = "Zum Anlegen eines neuen Tests "Neuer Test" klicken" |
|
240 | 240 | Info 2 = "Grunddaten anlegen oder bestehenden Test �ffnen" |
|
241 | 241 | Info 3 = "Testdaten anlegen" |
|
242 | 242 | Info 4 = "Der Schl�sselschalter muss in die Position "Einrichten" gebracht werden um die Einrichtbuttons zu aktivieren oder in die Position "Automatik" um den Test starten zu k�nnen oder den Strom manuell einzustellen!" |
|
243 | 243 | Info 5 = "Test geladen" |
|
244 | 244 | Info 6 = "Laufende Pr�fung..." |
|
245 | 245 | Info 7 = "Pr�fung erfolgreich abgeschlossen" |
|
246 | 246 | Info 8 = "Fehler aufgetreten!" |
|
247 | 247 | Info 9 = "Test abgebrochen!" |
|
248 | 248 | Info 10 = "Test abgebrochen! Maximale Temperatur wurde �berschritten" |
|
249 | 249 | Info 11 = "Test abgebrochen! Fehlerhafte Kontaktierung" |
|
250 | 250 | Info 12 = "Test abgebrochen! Messrate ist zu hoch" |
|
251 | 251 | Info 13 = "Test abgebrochen! Stromprofil- Generierung ist fehlgeschlagen" |
|
252 | 252 | Info 14 = "Test abgebrochen! Eingestellte Abschaltleistung der Stromquelle wurde erreicht" |
|
253 | 253 | Info 15 = "Test abgebrochen! Gemessener Strom liegt au�erhalb des definierten Bereichs" |
|
254 | 254 | Info 16 = "Testprotokoll wird erstellt... Bitte warten" |
|
255 | 255 | Info 17 = "Testprotokoll erstellt" |
|
256 | 256 | Info 18 = "Der letzte Test ist geladen..." |
|
257 | 257 | Info 19 = "Testdaten zur Testberichterstellung laden und ausw�hlen" |
|
258 | 258 | Info 20 = "Testbericht wird erstellt... Bitte warten" |
|
259 | 259 | Info 21 = "Testbericht erstellt" |
|
260 | 260 | Result.<size(s)> = "22" |
|
261 | 261 | Result 0 = "Not-Halt" |
|
262 | 262 | Result 1 = "" |
|
263 | 263 | Result 2 = "Bereit" |
|
264 | 264 | Result 3 = "Bereit" |
|
265 | 265 | Result 4 = "Einrichtbetrieb" |
|
266 | 266 | Result 5 = "Bereit" |
|
267 | 267 | Result 6 = "Pr�fung l�uft" |
|
268 | 268 | Result 7 = "Pr�fung fertig" |
|
269 | 269 | Result 8 = "Fehler" |
|
270 | 270 | Result 9 = "Pr�fung Stop" |
|
271 | 271 | Result 10 = "Pr�fung Stop" |
|
272 | 272 | Result 11 = "Pr�fung Stop" |
|
273 | 273 | Result 12 = "Pr�fung Stop" |
|
274 | 274 | Result 13 = "Pr�fung Stop" |
|
275 | 275 | Result 14 = "Pr�fung Stop" |
|
276 | 276 | Result 15 = "Pr�fung Stop" |
|
277 | 277 | Result 16 = "Bereit" |
|
278 | 278 | Result 17 = "Bereit" |
|
279 | 279 | Result 18 = "Bereit" |
|
280 | 280 | Result 19 = "Bereit" |
|
281 | 281 | Result 20 = "Bereit" |
|
282 | 282 | Result 21 = "Bereit" |
|
283 | 283 | |
|
284 | 284 | [DialogMessages] |
|
285 | 285 | Messages.<size(s)> = "7" |
|
286 | 286 | Messages 0 = "Achtung Einrichtbetrieb!\0AM�gliche Gefahren:\0A-Klemmgefahr\0A-Hei�e Oberfl�chen\0A-Lichtbogen" |
|
287 | 287 | Messages 1 = "Bitte achten Sie darauf, dass die hellblau markierten Felder in der gew�hlten Sprache sind" |
|
288 | 288 | Messages 2 = "Geben Sie die f�r die Testberichterstellung erforderlichen Daten ein. Bitte achten Sie darauf, dass die hellblau markierten Felder in der gew�hlten Sprache sind" |
|
289 | 289 | Messages 3 = "\0A\0A\0ADas Stromprofil f�r die gew�hlte Datengruppe ist nicht identisch!\0ABitte die Datenreihe mit dem nicht passenden Stromprofil entfernen" |
|
290 | 290 | Messages 4 = "W�hlen Sie eine Testkonfigurationsdatei zum Laden aus" |
|
291 | 291 | Messages 5 = "W�hlen Sie einen Ordner aus, der die Testergebnisse zum Laden enth�lt" |
|
292 | 292 | Messages 6 = "W�hlen Sie einen ID-Ordner aus, der alle Testergebnisse zum Laden enth�lt" No newline at end of file |
@@ -1,292 +1,292 | |||
|
1 | 1 | [Tester] |
|
2 | 2 | TesterType = "HSMP2" |
|
3 | 3 | TesterName = "Hochstrommessplatz 2" |
|
4 | 4 | MaxCurrent = 2000 |
|
5 | 5 | MaxTemperature = 250 |
|
6 | 6 | SensorsEnable.<size(s)> = "10" |
|
7 | 7 | SensorsEnable 0 = "True" |
|
8 | 8 | SensorsEnable 1 = "True" |
|
9 | 9 | SensorsEnable 2 = "True" |
|
10 | 10 | SensorsEnable 3 = "True" |
|
11 | 11 | SensorsEnable 4 = "True" |
|
12 | 12 | SensorsEnable 5 = "True" |
|
13 | 13 | SensorsEnable 6 = "True" |
|
14 | 14 | SensorsEnable 7 = "False" |
|
15 | 15 | SensorsEnable 8 = "False" |
|
16 | 16 | SensorsEnable 9 = "False" |
|
17 | 17 | SensorsDescription.<size(s)> = "10" |
|
18 | 18 | SensorsDescription 0 = "NI-9212: Ch1" |
|
19 | 19 | SensorsDescription 1 = "NI-9212: Ch2" |
|
20 | 20 | SensorsDescription 2 = "NI-9212: Ch3" |
|
21 | 21 | SensorsDescription 3 = "NI-9212: Ch4" |
|
22 | 22 | SensorsDescription 4 = "NI-9219: Ch1" |
|
23 | 23 | SensorsDescription 5 = "NI-9219: Ch2" |
|
24 | 24 | SensorsDescription 6 = "NI-9219: Ch3" |
|
25 | 25 | SensorsDescription 7 = "NI-9219: Ch4" |
|
26 | 26 | SensorsDescription 8 = "" |
|
27 | 27 | SensorsDescription 9 = "" |
|
28 | 28 | VoltageDescription.<size(s)> = "4 2" |
|
29 | 29 | VoltageDescription 0 = "NI-9215: Ch1" |
|
30 | 30 | VoltageDescription 1 = "Pr�flingsspannung [V]" |
|
31 | 31 | VoltageDescription 2 = "NI-9215: Ch2" |
|
32 | 32 | VoltageDescription 3 = "Zero Flux- Spannung [V]" |
|
33 | 33 | VoltageDescription 4 = "" |
|
34 | 34 | VoltageDescription 5 = "Strom [A]" |
|
35 | 35 | VoltageDescription 6 = "" |
|
36 | 36 | VoltageDescription 7 = "Widerstand [mOhm]" |
|
37 | 37 | CalibrationPassword = "48c8947f69c054a5caa934674ce8881d02bb18fb59d5a63eeaddff735b0e9801e87294783281ae49fc8287a0fd86779b27d7972d3e84f0fa0d826d7cb67dfefc" |
|
38 | 38 | |
|
39 | 39 | [Hardware] |
|
40 | 40 | SimulateDevices = True |
|
41 | 41 | DI_E-Stop = "" |
|
42 | 42 | DI_Setup = "" |
|
43 | 43 | PowerSupply_VISAName = "COM4" |
|
44 | 44 | PowerSupply_Address = "0" |
|
45 | 45 | PowerSupply_Baudrate = "9600" |
|
46 |
PowerSupply_OutputVoltage = " |
|
|
47 |
PowerSupply_OverVoltageProtection = " |
|
|
46 | PowerSupply_OutputVoltage = "10,000000" | |
|
47 | PowerSupply_OverVoltageProtection = "9,800000" | |
|
48 | 48 | PowerSupply_MinCurrent = "0" |
|
49 | 49 | PowerSupply_Check = False |
|
50 | 50 | PowerSupply_WarningPower = "18000,000000" |
|
51 | 51 | PowerSupply_AbortPower = "20000,000000" |
|
52 | 52 | PowerSupply_PID = "FALSE" |
|
53 | 53 | PowerSupply_PID_Time = "0,100000" |
|
54 | 54 | PowerSupply_PID_ProportionalGain = "0,100000" |
|
55 | 55 | PowerSupply_PID_IntegralTime = "0,180000" |
|
56 | 56 | PowerSupply_PID_DerivativeTime = "0,000000" |
|
57 | 57 | AbortCurrentDifference = "0,000000" |
|
58 | 58 | Measurement_Channels.<size(s)> = "13" |
|
59 | 59 | Measurement_Channels 0 = "NI9215/ai0" |
|
60 | 60 | Measurement_Channels 1 = "NI9215/ai1" |
|
61 | 61 | Measurement_Channels 2 = "NI9212/ai0" |
|
62 | 62 | Measurement_Channels 3 = "NI9212/ai1" |
|
63 | 63 | Measurement_Channels 4 = "NI9212/ai2" |
|
64 | 64 | Measurement_Channels 5 = "NI9212/ai3" |
|
65 | 65 | Measurement_Channels 6 = "NI9219/ai0" |
|
66 | 66 | Measurement_Channels 7 = "NI9219/ai1" |
|
67 | 67 | Measurement_Channels 8 = "NI9219/ai2" |
|
68 | 68 | Measurement_Channels 9 = "" |
|
69 | 69 | Measurement_Channels 10 = "" |
|
70 | 70 | Measurement_Channels 11 = "" |
|
71 | 71 | Measurement_Channels 12 = "" |
|
72 | 72 | ShuntResistance = "0,005" |
|
73 | 73 | Measurement_Check = False |
|
74 | 74 | DMM_VISAName = "NI9219/ai3" |
|
75 | 75 | DMM_ContactLimits = "<size(s)=2> 0,000000 10,000000" |
|
76 | 76 | TemperatureGain = "<size(s)=10> 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000" |
|
77 | 77 | TemperatureOffset = "<size(s)=10> 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000" |
|
78 | 78 | VoltageGain = "<size(s)=4> 1,000000 1,000000 1,000000 1,000000" |
|
79 | 79 | VoltageOffset = "<size(s)=4> 0,000000 0,000000 0,000000 0,000000" |
|
80 | 80 | AllowedContactFails = "2" |
|
81 | 81 | |
|
82 | 82 | [HSMP2] |
|
83 | 83 | DMM_Configuration.Maximum = "10,000000" |
|
84 | 84 | DMM_Configuration.Minimum = "-10,000000" |
|
85 | 85 | DMM_Configuration.Configuration = "2-Wire" |
|
86 | 86 | DMM_Configuration.CurrentExcitationSource = "Internal" |
|
87 | 87 | DMM_Configuration.CurrentExcitationValue = "0,000100" |
|
88 | 88 | Configuration_AI_Voltage.<size(s)> = "2" |
|
89 | 89 | Configuration_AI_Voltage 0.Maximum = "10,000000" |
|
90 | 90 | Configuration_AI_Voltage 0.Minimum = "-10,000000" |
|
91 | 91 | Configuration_AI_Voltage 0.InputTerminalConfiguration = "Differential" |
|
92 | 92 | Configuration_AI_Voltage 1.Maximum = "10,000000" |
|
93 | 93 | Configuration_AI_Voltage 1.Minimum = "0,000000" |
|
94 | 94 | Configuration_AI_Voltage 1.InputTerminalConfiguration = "Differential" |
|
95 | 95 | Configuration_AI_Thermocouple.<size(s)> = "10" |
|
96 | 96 | Configuration_AI_Thermocouple 0.Maximum = "250,000000" |
|
97 | 97 | Configuration_AI_Thermocouple 0.Minimum = "-200,000000" |
|
98 | 98 | Configuration_AI_Thermocouple 0.Type = "K" |
|
99 | 99 | Configuration_AI_Thermocouple 0.CJC_Source = "Built-In" |
|
100 | 100 | Configuration_AI_Thermocouple 0.CJC_Value = "25,000000" |
|
101 | 101 | Configuration_AI_Thermocouple 1.Maximum = "250,000000" |
|
102 | 102 | Configuration_AI_Thermocouple 1.Minimum = "-200,000000" |
|
103 | 103 | Configuration_AI_Thermocouple 1.Type = "K" |
|
104 | 104 | Configuration_AI_Thermocouple 1.CJC_Source = "Built-In" |
|
105 | 105 | Configuration_AI_Thermocouple 1.CJC_Value = "25,000000" |
|
106 | 106 | Configuration_AI_Thermocouple 2.Maximum = "250,000000" |
|
107 | 107 | Configuration_AI_Thermocouple 2.Minimum = "-200,000000" |
|
108 | 108 | Configuration_AI_Thermocouple 2.Type = "K" |
|
109 | 109 | Configuration_AI_Thermocouple 2.CJC_Source = "Built-In" |
|
110 | 110 | Configuration_AI_Thermocouple 2.CJC_Value = "25,000000" |
|
111 | 111 | Configuration_AI_Thermocouple 3.Maximum = "250,000000" |
|
112 | 112 | Configuration_AI_Thermocouple 3.Minimum = "-200,000000" |
|
113 | 113 | Configuration_AI_Thermocouple 3.Type = "K" |
|
114 | 114 | Configuration_AI_Thermocouple 3.CJC_Source = "Built-In" |
|
115 | 115 | Configuration_AI_Thermocouple 3.CJC_Value = "10,000000" |
|
116 | 116 | Configuration_AI_Thermocouple 4.Maximum = "250,000000" |
|
117 | 117 | Configuration_AI_Thermocouple 4.Minimum = "-200,000000" |
|
118 | 118 | Configuration_AI_Thermocouple 4.Type = "K" |
|
119 | 119 | Configuration_AI_Thermocouple 4.CJC_Source = "Built-In" |
|
120 | 120 | Configuration_AI_Thermocouple 4.CJC_Value = "25,000000" |
|
121 | 121 | Configuration_AI_Thermocouple 5.Maximum = "250,000000" |
|
122 | 122 | Configuration_AI_Thermocouple 5.Minimum = "-200,000000" |
|
123 | 123 | Configuration_AI_Thermocouple 5.Type = "K" |
|
124 | 124 | Configuration_AI_Thermocouple 5.CJC_Source = "Built-In" |
|
125 | 125 | Configuration_AI_Thermocouple 5.CJC_Value = "25,000000" |
|
126 | 126 | Configuration_AI_Thermocouple 6.Maximum = "250,000000" |
|
127 | 127 | Configuration_AI_Thermocouple 6.Minimum = "-200,000000" |
|
128 | 128 | Configuration_AI_Thermocouple 6.Type = "K" |
|
129 | 129 | Configuration_AI_Thermocouple 6.CJC_Source = "Built-In" |
|
130 | 130 | Configuration_AI_Thermocouple 6.CJC_Value = "25,000000" |
|
131 | 131 | Configuration_AI_Thermocouple 7.Maximum = "250,000000" |
|
132 | 132 | Configuration_AI_Thermocouple 7.Minimum = "-200,000000" |
|
133 | 133 | Configuration_AI_Thermocouple 7.Type = "K" |
|
134 | 134 | Configuration_AI_Thermocouple 7.CJC_Source = "Built-In" |
|
135 | 135 | Configuration_AI_Thermocouple 7.CJC_Value = "25,000000" |
|
136 | 136 | Configuration_AI_Thermocouple 8.Maximum = "250,000000" |
|
137 | 137 | Configuration_AI_Thermocouple 8.Minimum = "-200,000000" |
|
138 | 138 | Configuration_AI_Thermocouple 8.Type = "K" |
|
139 | 139 | Configuration_AI_Thermocouple 8.CJC_Source = "Built-In" |
|
140 | 140 | Configuration_AI_Thermocouple 8.CJC_Value = "25,000000" |
|
141 | 141 | Configuration_AI_Thermocouple 9.Maximum = "250,000000" |
|
142 | 142 | Configuration_AI_Thermocouple 9.Minimum = "-200,000000" |
|
143 | 143 | Configuration_AI_Thermocouple 9.Type = "K" |
|
144 | 144 | Configuration_AI_Thermocouple 9.CJC_Source = "Built-In" |
|
145 | 145 | Configuration_AI_Thermocouple 9.CJC_Value = "25,000000" |
|
146 | 146 | Configuration_AI_NI9219_Resistance.<size(s)> = "4" |
|
147 | 147 | Configuration_AI_NI9219_Resistance 0.Maximum = "10500,000000" |
|
148 | 148 | Configuration_AI_NI9219_Resistance 0.Minimum = "0,000000" |
|
149 | 149 | Configuration_AI_NI9219_Resistance 0.Configuration = "2-Wire" |
|
150 | 150 | Configuration_AI_NI9219_Resistance 0.CurrentExcitationSource = "Internal" |
|
151 | 151 | Configuration_AI_NI9219_Resistance 0.CurrentExcitationValue = "0,000500" |
|
152 | 152 | Configuration_AI_NI9219_Resistance 0.RTD_Type = "Pt3750" |
|
153 | 153 | Configuration_AI_NI9219_Resistance 0.R0 = "1000,000000" |
|
154 | 154 | Configuration_AI_NI9219_Resistance 0.ABC = "<size(s)=3> 1,224312924E-3 2,308955523E-4 3,938074268E-9" |
|
155 | 155 | Configuration_AI_NI9219_Resistance 1.Maximum = "250,000000" |
|
156 | 156 | Configuration_AI_NI9219_Resistance 1.Minimum = "-200,000000" |
|
157 | 157 | Configuration_AI_NI9219_Resistance 1.Configuration = "2-Wire" |
|
158 | 158 | Configuration_AI_NI9219_Resistance 1.CurrentExcitationSource = "Internal" |
|
159 | 159 | Configuration_AI_NI9219_Resistance 1.CurrentExcitationValue = "0,000500" |
|
160 | 160 | Configuration_AI_NI9219_Resistance 1.RTD_Type = "Pt3750" |
|
161 | 161 | Configuration_AI_NI9219_Resistance 1.R0 = "1000,000000" |
|
162 | 162 | Configuration_AI_NI9219_Resistance 1.ABC = "<size(s)=3> 1,224312924E-3 2,308955523E-4 3,938074268E-9" |
|
163 | 163 | Configuration_AI_NI9219_Resistance 2.Maximum = "250,000000" |
|
164 | 164 | Configuration_AI_NI9219_Resistance 2.Minimum = "-200,000000" |
|
165 | 165 | Configuration_AI_NI9219_Resistance 2.Configuration = "2-Wire" |
|
166 | 166 | Configuration_AI_NI9219_Resistance 2.CurrentExcitationSource = "Internal" |
|
167 | 167 | Configuration_AI_NI9219_Resistance 2.CurrentExcitationValue = "0,000500" |
|
168 | 168 | Configuration_AI_NI9219_Resistance 2.RTD_Type = "Pt3750" |
|
169 | 169 | Configuration_AI_NI9219_Resistance 2.R0 = "1000,000000" |
|
170 | 170 | Configuration_AI_NI9219_Resistance 2.ABC = "<size(s)=3> 3,81E-3 -6,02E-7 -6E-12" |
|
171 | 171 | Configuration_AI_NI9219_Resistance 3.Maximum = "250,000000" |
|
172 | 172 | Configuration_AI_NI9219_Resistance 3.Minimum = "-200,000000" |
|
173 | 173 | Configuration_AI_NI9219_Resistance 3.Configuration = "2-Wire" |
|
174 | 174 | Configuration_AI_NI9219_Resistance 3.CurrentExcitationSource = "Internal" |
|
175 | 175 | Configuration_AI_NI9219_Resistance 3.CurrentExcitationValue = "0,000500" |
|
176 | 176 | Configuration_AI_NI9219_Resistance 3.RTD_Type = "Pt3750" |
|
177 | 177 | Configuration_AI_NI9219_Resistance 3.R0 = "1000,000000" |
|
178 | 178 | Configuration_AI_NI9219_Resistance 3.ABC = "<size(s)=3> 1,224312924E-3 2,308955523E-4 3,938074268E-9" |
|
179 | 179 | Configuration_AI_NI9219_Type.<size(s)> = "4" |
|
180 | 180 | Configuration_AI_NI9219_Type 0 = "Thermocouple" |
|
181 | 181 | Configuration_AI_NI9219_Type 1 = "Thermocouple" |
|
182 | 182 | Configuration_AI_NI9219_Type 2 = "Resistance_RTD" |
|
183 | 183 | Configuration_AI_NI9219_Type 3 = "Thermocouple" |
|
184 | 184 | |
|
185 | 185 | [DefaultValues] |
|
186 | 186 | WorkingStroke = "0" |
|
187 | 187 | MaxTemperature = "<size(s)=10> 50,000000 250,000000 250,000000 250,000000 250,000000 250,000000 250,000000 250,000000 250,000000 250,000000" |
|
188 | 188 | MeasurementTime = "1" |
|
189 | 189 | NominalCurrent = "0" |
|
190 | 190 | TableControl = False |
|
191 | 191 | SensorsColor = "<size(s)=10> 16776960 16711680 16744448 16744640 16711935 10879142 8388863 8421631 423327 9567230" |
|
192 | 192 | Sensors+.<size(s)> = "10" |
|
193 | 193 | Sensors+ 0 = "True" |
|
194 | 194 | Sensors+ 1 = "True" |
|
195 | 195 | Sensors+ 2 = "True" |
|
196 | 196 | Sensors+ 3 = "True" |
|
197 | 197 | Sensors+ 4 = "True" |
|
198 | 198 | Sensors+ 5 = "False" |
|
199 | 199 | Sensors+ 6 = "False" |
|
200 | 200 | Sensors+ 7 = "False" |
|
201 | 201 | Sensors+ 8 = "False" |
|
202 | 202 | Sensors+ 9 = "False" |
|
203 | 203 | SensorsFunction.<size(s)> = "10" |
|
204 | 204 | SensorsFunction 0 = "Umgebungstemperatur" |
|
205 | 205 | SensorsFunction 1 = "Pr�flingstemperatur" |
|
206 | 206 | SensorsFunction 2 = "Temperatur 3" |
|
207 | 207 | SensorsFunction 3 = "Temperatur 4" |
|
208 | 208 | SensorsFunction 4 = "Temperatur 5" |
|
209 | 209 | SensorsFunction 5 = "Temperatur 6" |
|
210 | 210 | SensorsFunction 6 = "Temperatur 7" |
|
211 | 211 | SensorsFunction 7 = "Temperatur 8" |
|
212 | 212 | SensorsFunction 8 = "Temperatur 9" |
|
213 | 213 | SensorsFunction 9 = "Temperatur 10" |
|
214 | 214 | |
|
215 | 215 | [Pathes] |
|
216 | 216 | User = "C:\Work\CurrentTester\support\User.txt" |
|
217 | 217 | ReportsFolder = "C:\Work\CurrentTester\support\ResultData_HSMP2" |
|
218 | 218 | ProtocolsFolder = "C:\Work\CurrentTester\support\ResultData_HSMP2\Protocols" |
|
219 | 219 | CurrentProfilesFolder = "C:\Work\CurrentTester\support\CurrentProfiles" |
|
220 | 220 | Applicants = "C:\Work\CurrentTester\support\Applicants.txt" |
|
221 | 221 | |
|
222 | 222 | [Report] |
|
223 | 223 | FileNameFormat = "%s_TestResults.txt" |
|
224 | 224 | ReportNameFormat = "%s_TestReport_%s.xlsx" |
|
225 | 225 | ReportTemplate_German = "C:\Work\CurrentTester\support\ReportTemplates\TemplateGerman.xlsx" |
|
226 | 226 | ReportTemplate_English = "C:\Work\CurrentTester\support\ReportTemplates\TemplateEnglish.xlsx" |
|
227 | 227 | |
|
228 | 228 | [Protocol] |
|
229 | 229 | ProtocolNameFormat = "%s_A%d_Report_%s.docx" |
|
230 | 230 | ProtocolTemplate_German = "C:\Work\CurrentTester\support\ReportTemplates\ProtocolTemplateGerman.dotx" |
|
231 | 231 | ProtocolTemplate_English = "C:\Work\CurrentTester\support\ReportTemplates\ProtocolTemplateEnglish.dotx" |
|
232 | 232 | ProtocolComment_German = "Alle Messungen sind mit einem galvanisch isoliertem Thermosensor Type K durchf�hrt worden.\0ADie Testergebnisse und Auswertungen beziehen sich ausschlie�lich auf die Muster, die zu diesem Test unter Laborbedingungen verwendet wurden und auf den verwendeten Testaufbau!" |
|
233 | 233 | ProtocolComment_English = "All measurements were carried out with a galvanically isolated Type K thermal sensors.\0AThe test results and evaluations refer exclusively to the samples that were used for this test under laboratory conditions and to the test setup used!" |
|
234 | 234 | ProtocolDataFolderName = "Bilder|Messungen" |
|
235 | 235 | |
|
236 | 236 | [StateMessages] |
|
237 | 237 | Info.<size(s)> = "22" |
|
238 | 238 | Info 0 = "Aktivierter Not-Halt oder eine T�r steht offen! Ein Teststart ist nicht m�glich" |
|
239 | 239 | Info 1 = "Zum Anlegen eines neuen Tests "Neuer Test" klicken" |
|
240 | 240 | Info 2 = "Grunddaten anlegen oder bestehenden Test �ffnen" |
|
241 | 241 | Info 3 = "Testdaten anlegen" |
|
242 | 242 | Info 4 = "Der Schl�sselschalter muss in die Position "Einrichten" gebracht werden um die Einrichtbuttons zu aktivieren oder in die Position "Automatik" um den Test starten zu k�nnen oder den Strom manuell einzustellen!" |
|
243 | 243 | Info 5 = "Test geladen" |
|
244 | 244 | Info 6 = "Laufende Pr�fung..." |
|
245 | 245 | Info 7 = "Pr�fung erfolgreich abgeschlossen" |
|
246 | 246 | Info 8 = "Fehler aufgetreten!" |
|
247 | 247 | Info 9 = "Test abgebrochen!" |
|
248 | 248 | Info 10 = "Test abgebrochen! Maximale Temperatur wurde �berschritten" |
|
249 | 249 | Info 11 = "Test abgebrochen! Fehlerhafte Kontaktierung" |
|
250 | 250 | Info 12 = "Test abgebrochen! Messrate ist zu hoch" |
|
251 | 251 | Info 13 = "Test abgebrochen! Stromprofil- Generierung ist fehlgeschlagen" |
|
252 | 252 | Info 14 = "Test abgebrochen! Eingestellte Abschaltleistung der Stromquelle wurde erreicht" |
|
253 | 253 | Info 15 = "Test abgebrochen! Gemessener Strom liegt au�erhalb des definierten Bereichs" |
|
254 | 254 | Info 16 = "Testprotokoll wird erstellt... Bitte warten" |
|
255 | 255 | Info 17 = "Testprotokoll erstellt" |
|
256 | 256 | Info 18 = "Der letzte Test ist geladen..." |
|
257 | 257 | Info 19 = "Testdaten zur Testberichterstellung laden und ausw�hlen" |
|
258 | 258 | Info 20 = "Testbericht wird erstellt... Bitte warten" |
|
259 | 259 | Info 21 = "Testbericht erstellt" |
|
260 | 260 | Result.<size(s)> = "22" |
|
261 | 261 | Result 0 = "Not-Halt" |
|
262 | 262 | Result 1 = "" |
|
263 | 263 | Result 2 = "Bereit" |
|
264 | 264 | Result 3 = "Bereit" |
|
265 | 265 | Result 4 = "Einrichtbetrieb" |
|
266 | 266 | Result 5 = "Bereit" |
|
267 | 267 | Result 6 = "Pr�fung l�uft" |
|
268 | 268 | Result 7 = "Pr�fung fertig" |
|
269 | 269 | Result 8 = "Fehler" |
|
270 | 270 | Result 9 = "Pr�fung Stop" |
|
271 | 271 | Result 10 = "Pr�fung Stop" |
|
272 | 272 | Result 11 = "Pr�fung Stop" |
|
273 | 273 | Result 12 = "Pr�fung Stop" |
|
274 | 274 | Result 13 = "Pr�fung Stop" |
|
275 | 275 | Result 14 = "Pr�fung Stop" |
|
276 | 276 | Result 15 = "Pr�fung Stop" |
|
277 | 277 | Result 16 = "Bereit" |
|
278 | 278 | Result 17 = "Bereit" |
|
279 | 279 | Result 18 = "Bereit" |
|
280 | 280 | Result 19 = "Bereit" |
|
281 | 281 | Result 20 = "Bereit" |
|
282 | 282 | Result 21 = "Bereit" |
|
283 | 283 | |
|
284 | 284 | [DialogMessages] |
|
285 | 285 | Messages.<size(s)> = "7" |
|
286 | 286 | Messages 0 = "Achtung Einrichtbetrieb!\0AM�gliche Gefahren:\0A-Klemmgefahr\0A-Hei�e Oberfl�chen\0A-Lichtbogen" |
|
287 | 287 | Messages 1 = "Bitte achten Sie darauf, dass die hellblau markierten Felder in der gew�hlten Sprache sind" |
|
288 | 288 | Messages 2 = "Geben Sie die f�r die Testberichterstellung erforderlichen Daten ein. Bitte achten Sie darauf, dass die hellblau markierten Felder in der gew�hlten Sprache sind" |
|
289 | 289 | Messages 3 = "\0A\0A\0ADas Stromprofil f�r die gew�hlte Datengruppe ist nicht identisch!\0ABitte die Datenreihe mit dem nicht passenden Stromprofil entfernen" |
|
290 | 290 | Messages 4 = "W�hlen Sie eine Testkonfigurationsdatei zum Laden aus" |
|
291 | 291 | Messages 5 = "W�hlen Sie einen Ordner aus, der die Testergebnisse zum Laden enth�lt" |
|
292 | 292 | Messages 6 = "W�hlen Sie einen ID-Ordner aus, der alle Testergebnisse zum Laden enth�lt" No newline at end of file |
|