# SVN changeset patch # User LabVIEW # Date 2025-09-05 08:37:42.224038 # Revision 66 - Word-Template De updated; - lib_System.lvlibp updated for file name (X) Index: CurrentTester [LabVIEW]/CurrentTester.lvproj =================================================================== diff --git a/CurrentTester [LabVIEW]/CurrentTester.lvproj b/CurrentTester [LabVIEW]/CurrentTester.lvproj --- a/CurrentTester [LabVIEW]/CurrentTester.lvproj (revision 65) +++ b/CurrentTester [LabVIEW]/CurrentTester.lvproj (revision 66) @@ -491,135 +491,95 @@ - - - - - - - - - - - - - - - - - + - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + - - - - - - - - - - - - - - - - - + + + + + + + + + + - + + + + + + + + + + + + + - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - + + true Index: CurrentTester [LabVIEW]/Initialization.ini =================================================================== diff --git a/CurrentTester [LabVIEW]/Initialization.ini b/CurrentTester [LabVIEW]/Initialization.ini --- a/CurrentTester [LabVIEW]/Initialization.ini (revision 65) +++ b/CurrentTester [LabVIEW]/Initialization.ini (revision 66) @@ -1,7 +1,7 @@ [Tester] -TesterType = "HSMP2" -TesterName = "Hochstrommessplatz 2" -MaxCurrent = 2000 +TesterType = "SMP3" +TesterName = "Strommessplatz 3" +MaxCurrent = 130 MaxTemperature = 250 MaxAmbientTemperature = 50 TemperatureWarning- = 10 @@ -14,34 +14,34 @@ SensorsEnable 5 = "True" SensorsEnable 6 = "True" SensorsEnable 7 = "True" -SensorsEnable 8 = "True" -SensorsEnable 9 = "True" +SensorsEnable 8 = "False" +SensorsEnable 9 = "False" SensorsEnable 10 = "False" SensorsEnable 11 = "False" SensorsEnable 12 = "False" SensorsEnable 13 = "False" SensorsEnable 14 = "False" SensorsDescription. = "15" -SensorsDescription 0 = "NI-9212: Ch0" -SensorsDescription 1 = "NI-9212: Ch1" -SensorsDescription 2 = "NI-9212: Ch2" -SensorsDescription 3 = "NI-9212: Ch3" -SensorsDescription 4 = "NI-9212: Ch4" -SensorsDescription 5 = "NI-9212: Ch5" -SensorsDescription 6 = "NI-9212: Ch6" -SensorsDescription 7 = "NI-9212: Ch7" -SensorsDescription 8 = "NI-9219_1: Ch0" -SensorsDescription 9 = "NI-9219_1: Ch1" -SensorsDescription 10 = "NI-9219_1: Ch2" -SensorsDescription 11 = "NI-9219_2: Ch0" -SensorsDescription 12 = "NI-9219_2: Ch1" -SensorsDescription 13 = "NI-9219_2: Ch2" -SensorsDescription 14 = "NI-9219_2: Ch3" +SensorsDescription 0 = "NI-9210: Ch0" +SensorsDescription 1 = "NI-9210: Ch1" +SensorsDescription 2 = "NI-9210: Ch2" +SensorsDescription 3 = "NI-9210: Ch3" +SensorsDescription 4 = "NI-9219: Ch0" +SensorsDescription 5 = "NI-9219: Ch1" +SensorsDescription 6 = "NI-9219: Ch2" +SensorsDescription 7 = "NI-9219: Ch3" +SensorsDescription 8 = "" +SensorsDescription 9 = "" +SensorsDescription 10 = "" +SensorsDescription 11 = "" +SensorsDescription 12 = "" +SensorsDescription 13 = "" +SensorsDescription 14 = "" VoltageDescription. = "5 2" -VoltageDescription 0 = "NI-9215: Ch0" +VoltageDescription 0 = "NI PXI-6281: Ch3" VoltageDescription 1 = "Pr�flingsspannung [V]" -VoltageDescription 2 = "NI-9219_1: Ch2" -VoltageDescription 3 = "Zero Flux- Spannung [V]" +VoltageDescription 2 = "NI PXI-6281: Ch4" +VoltageDescription 3 = "Shunt- Spannung [V]" VoltageDescription 4 = "" VoltageDescription 5 = "Strom [A]" VoltageDescription 6 = "" @@ -51,235 +51,145 @@ CalibrationPassword = "48c8947f69c054a5caa934674ce8881d02bb18fb59d5a63eeaddff735b0e9801e87294783281ae49fc8287a0fd86779b27d7972d3e84f0fa0d826d7cb67dfefc" [Hardware] -SimulateDevices = False -DI_E-Stop = "" -DI_Setup = "" -PowerSupply_VISAName = "TCPIP0::10.1.2.40::30000::SOCKET" -PowerSupply_Address = "0" -PowerSupply_Baudrate = "0" -PowerSupply_OutputVoltage = "10,000000" -PowerSupply_OverVoltageProtection = "9,800000" +SimulateDevices = True +DI_E-Stop = "PXI1Slot5/port0/line5" +DI_Setup = "PXI1Slot5/port0/line4" +PowerSupply_VISAName = "COM4" +PowerSupply_Address = "1" +PowerSupply_Baudrate = "9600" +PowerSupply_OutputVoltage = "5,500000" +PowerSupply_OverVoltageProtection = "6,000000" PowerSupply_MinCurrent = "0" PowerSupply_Check = False -PowerSupply_WarningPower = "4000,000000" -PowerSupply_AbortPower = "5000,000000" -PowerSupply_PID = "FALSE" -PowerSupply_PID_Time = "1,000000" +PowerSupply_WarningPower = "200,000000" +PowerSupply_AbortPower = "250,000000" +PowerSupply_PID = "False" +PowerSupply_PID_Time = "0,100000" PowerSupply_PID_ProportionalGain = "0,100000" PowerSupply_PID_IntegralTime = "0,180000" PowerSupply_PID_DerivativeTime = "0,000000" -AbortCurrentDifference = "0,000000" +AbortCurrentDifference = "50" Measurement_Channels. = "17" -Measurement_Channels 0 = "NI9215/ai0" -Measurement_Channels 1 = "NI9219_1/ai2" -Measurement_Channels 2 = "NI9212/ai0" -Measurement_Channels 3 = "NI9212/ai1" -Measurement_Channels 4 = "NI9212/ai2" -Measurement_Channels 5 = "NI9212/ai3" -Measurement_Channels 6 = "NI9212/ai4" -Measurement_Channels 7 = "NI9212/ai5" -Measurement_Channels 8 = "NI9212/ai6" -Measurement_Channels 9 = "NI9212/ai7" -Measurement_Channels 10 = "NI9219_1/ai0" -Measurement_Channels 11 = "NI9219_1/ai1" -Measurement_Channels 12 = "NI9219_1/ai2" -Measurement_Channels 13 = "NI9219_2/ai0" -Measurement_Channels 14 = "NI9219_2/ai1" -Measurement_Channels 15 = "NI9219_2/ai2" -Measurement_Channels 16 = "NI9219_2/ai3" -Measurement_Sample = " 40,000000 40,000000 2,000000 2,000000 2,000000 2,000000 2,000000 2,000000 2,000000 2,000000 40,000000 40,000000 40,000000 40,000000 40,000000 40,000000 40,000000" -ShuntResistance = "0,005" +Measurement_Channels 0 = "PXI1Slot5/ai4" +Measurement_Channels 1 = "PXI1Slot5/ai5" +Measurement_Channels 2 = "NI9210/ai0" +Measurement_Channels 3 = "NI9210/ai1" +Measurement_Channels 4 = "NI9210/ai2" +Measurement_Channels 5 = "NI9210/ai3" +Measurement_Channels 6 = "NI9219/ai0" +Measurement_Channels 7 = "NI9219/ai1" +Measurement_Channels 8 = "NI9219/ai2" +Measurement_Channels 9 = "NI9219/ai3" +Measurement_Channels 10 = "" +Measurement_Channels 11 = "" +Measurement_Channels 12 = "" +Measurement_Channels 13 = "" +Measurement_Channels 14 = "" +Measurement_Channels 15 = "" +Measurement_Channels 16 = "" +Measurement_Sample = " 1,000000 1,000000 2,000000 2,000000 2,000000 2,000000 40,000000 40,000000 40,000000 40,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000" +ShuntResistance = 0,001 Measurement_Check = False Measurement_Delay = "1" -DMM_VISAName = "NI9219_1/ai3" -DMM_ContactLimits = " 0,000000 10,000000" +DMM_VISAName = "PXI1Slot3" +DMM_ContactLimits = " 0,0 1,0" TemperatureGain = " 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000" TemperatureOffset = " 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000" -VoltageGain = " 1,000000 -1,000000 1,000000 1,000000 1,000000" +VoltageGain = " 1,000000 1,000000 1,000000 1,000000 1,000000" VoltageOffset = " 0,000000 0,000000 0,000000 0,000000 0,000000" AllowedContactFails = "2" -[HSMP2] -DMM_Configuration.Maximum = "10500,000000" -DMM_Configuration.Minimum = "0,000000" -DMM_Configuration.Configuration = "4-Wire" -DMM_Configuration.CurrentExcitationSource = "Internal" -DMM_Configuration.CurrentExcitationValue = "0,000500" -DMM_Sample = "40,000000" +[SMP3] +DMM_Function = "2-wire Resistance" +DMM_AutoRange = False +DMM_Range = "0,020000" +DMM_Resolution = "0,001000" Configuration_AI_Voltage. = "2" -Configuration_AI_Voltage 0.Maximum = "10,000000" -Configuration_AI_Voltage 0.Minimum = "-10,000000" +Configuration_AI_Voltage 0.Maximum = "5,000000" +Configuration_AI_Voltage 0.Minimum = "-5,000000" Configuration_AI_Voltage 0.InputTerminalConfiguration = "Differential" -Configuration_AI_Voltage 1.Maximum = "10,000000" -Configuration_AI_Voltage 1.Minimum = "0,000000" +Configuration_AI_Voltage 1.Maximum = "1,000000" +Configuration_AI_Voltage 1.Minimum = "-1,000000" Configuration_AI_Voltage 1.InputTerminalConfiguration = "Differential" -Configuration_AI_Thermocouple. = "15" +Configuration_AI_Thermocouple. = "8" Configuration_AI_Thermocouple 0.Maximum = "250,000000" -Configuration_AI_Thermocouple 0.Minimum = "0,000000" +Configuration_AI_Thermocouple 0.Minimum = "-200,000000" Configuration_AI_Thermocouple 0.Type = "K" Configuration_AI_Thermocouple 0.CJC_Source = "Built-In" Configuration_AI_Thermocouple 0.CJC_Value = "25,000000" Configuration_AI_Thermocouple 1.Maximum = "250,000000" -Configuration_AI_Thermocouple 1.Minimum = "0,000000" +Configuration_AI_Thermocouple 1.Minimum = "-200,000000" Configuration_AI_Thermocouple 1.Type = "K" Configuration_AI_Thermocouple 1.CJC_Source = "Built-In" Configuration_AI_Thermocouple 1.CJC_Value = "25,000000" Configuration_AI_Thermocouple 2.Maximum = "250,000000" -Configuration_AI_Thermocouple 2.Minimum = "0,000000" +Configuration_AI_Thermocouple 2.Minimum = "-200,000000" Configuration_AI_Thermocouple 2.Type = "K" Configuration_AI_Thermocouple 2.CJC_Source = "Built-In" Configuration_AI_Thermocouple 2.CJC_Value = "25,000000" Configuration_AI_Thermocouple 3.Maximum = "250,000000" -Configuration_AI_Thermocouple 3.Minimum = "0,000000" +Configuration_AI_Thermocouple 3.Minimum = "-200,000000" Configuration_AI_Thermocouple 3.Type = "K" Configuration_AI_Thermocouple 3.CJC_Source = "Built-In" Configuration_AI_Thermocouple 3.CJC_Value = "10,000000" Configuration_AI_Thermocouple 4.Maximum = "250,000000" -Configuration_AI_Thermocouple 4.Minimum = "0,000000" +Configuration_AI_Thermocouple 4.Minimum = "-200,000000" Configuration_AI_Thermocouple 4.Type = "K" Configuration_AI_Thermocouple 4.CJC_Source = "Built-In" Configuration_AI_Thermocouple 4.CJC_Value = "25,000000" Configuration_AI_Thermocouple 5.Maximum = "250,000000" -Configuration_AI_Thermocouple 5.Minimum = "0,000000" +Configuration_AI_Thermocouple 5.Minimum = "-200,000000" Configuration_AI_Thermocouple 5.Type = "K" Configuration_AI_Thermocouple 5.CJC_Source = "Built-In" Configuration_AI_Thermocouple 5.CJC_Value = "25,000000" Configuration_AI_Thermocouple 6.Maximum = "250,000000" -Configuration_AI_Thermocouple 6.Minimum = "0,000000" +Configuration_AI_Thermocouple 6.Minimum = "-200,000000" Configuration_AI_Thermocouple 6.Type = "K" Configuration_AI_Thermocouple 6.CJC_Source = "Built-In" Configuration_AI_Thermocouple 6.CJC_Value = "25,000000" Configuration_AI_Thermocouple 7.Maximum = "250,000000" -Configuration_AI_Thermocouple 7.Minimum = "0,000000" +Configuration_AI_Thermocouple 7.Minimum = "-200,000000" Configuration_AI_Thermocouple 7.Type = "K" Configuration_AI_Thermocouple 7.CJC_Source = "Built-In" Configuration_AI_Thermocouple 7.CJC_Value = "25,000000" -Configuration_AI_Thermocouple 8.Maximum = "250,000000" -Configuration_AI_Thermocouple 8.Minimum = "0,000000" -Configuration_AI_Thermocouple 8.Type = "K" -Configuration_AI_Thermocouple 8.CJC_Source = "Built-In" -Configuration_AI_Thermocouple 8.CJC_Value = "25,000000" -Configuration_AI_Thermocouple 9.Maximum = "250,000000" -Configuration_AI_Thermocouple 9.Minimum = "0,000000" -Configuration_AI_Thermocouple 9.Type = "K" -Configuration_AI_Thermocouple 9.CJC_Source = "Built-In" -Configuration_AI_Thermocouple 9.CJC_Value = "25,000000" -Configuration_AI_Thermocouple 10.Maximum = "250,000000" -Configuration_AI_Thermocouple 10.Minimum = "0,000000" -Configuration_AI_Thermocouple 10.Type = "K" -Configuration_AI_Thermocouple 10.CJC_Source = "Built-In" -Configuration_AI_Thermocouple 10.CJC_Value = "25,000000" -Configuration_AI_Thermocouple 11.Maximum = "250,000000" -Configuration_AI_Thermocouple 11.Minimum = "-200,000000" -Configuration_AI_Thermocouple 11.Type = "K" -Configuration_AI_Thermocouple 11.CJC_Source = "Built-In" -Configuration_AI_Thermocouple 11.CJC_Value = "25,000000" -Configuration_AI_Thermocouple 12.Maximum = "250,000000" -Configuration_AI_Thermocouple 12.Minimum = "-200,000000" -Configuration_AI_Thermocouple 12.Type = "K" -Configuration_AI_Thermocouple 12.CJC_Source = "Built-In" -Configuration_AI_Thermocouple 12.CJC_Value = "25,000000" -Configuration_AI_Thermocouple 13.Maximum = "250,000000" -Configuration_AI_Thermocouple 13.Minimum = "-200,000000" -Configuration_AI_Thermocouple 13.Type = "K" -Configuration_AI_Thermocouple 13.CJC_Source = "Built-In" -Configuration_AI_Thermocouple 13.CJC_Value = "10,000000" -Configuration_AI_Thermocouple 14.Maximum = "250,000000" -Configuration_AI_Thermocouple 14.Minimum = "-200,000000" -Configuration_AI_Thermocouple 14.Type = "K" -Configuration_AI_Thermocouple 14.CJC_Source = "Built-In" -Configuration_AI_Thermocouple 14.CJC_Value = "25,000000" -Configuration_AI_NI9219_Resistance. = "7" -Configuration_AI_NI9219_Resistance 0.Maximum = "800,000000" +Configuration_AI_NI9219_Resistance. = "4" +Configuration_AI_NI9219_Resistance 0.Maximum = "10500,000000" Configuration_AI_NI9219_Resistance 0.Minimum = "0,000000" -Configuration_AI_NI9219_Resistance 0.Configuration = "4-Wire" +Configuration_AI_NI9219_Resistance 0.Configuration = "2-Wire" Configuration_AI_NI9219_Resistance 0.CurrentExcitationSource = "Internal" Configuration_AI_NI9219_Resistance 0.CurrentExcitationValue = "0,000500" Configuration_AI_NI9219_Resistance 0.RTD_Type = "Pt3750" Configuration_AI_NI9219_Resistance 0.R0 = "1000,000000" -Configuration_AI_NI9219_Resistance 0.ABC = " 1,224E-3 2,31E-4 3,938074E-9" +Configuration_AI_NI9219_Resistance 0.ABC = " 1,224312924E-3 2,308955523E-4 3,938074268E-9" Configuration_AI_NI9219_Resistance 1.Maximum = "250,000000" -Configuration_AI_NI9219_Resistance 1.Minimum = "0,000000" +Configuration_AI_NI9219_Resistance 1.Minimum = "-200,000000" Configuration_AI_NI9219_Resistance 1.Configuration = "2-Wire" Configuration_AI_NI9219_Resistance 1.CurrentExcitationSource = "Internal" Configuration_AI_NI9219_Resistance 1.CurrentExcitationValue = "0,000500" Configuration_AI_NI9219_Resistance 1.RTD_Type = "Pt3750" Configuration_AI_NI9219_Resistance 1.R0 = "1000,000000" -Configuration_AI_NI9219_Resistance 1.ABC = " 1,224E-3 2,31E-4 3,938074E-9" +Configuration_AI_NI9219_Resistance 1.ABC = " 1,224312924E-3 2,308955523E-4 3,938074268E-9" Configuration_AI_NI9219_Resistance 2.Maximum = "250,000000" -Configuration_AI_NI9219_Resistance 2.Minimum = "0,000000" +Configuration_AI_NI9219_Resistance 2.Minimum = "-200,000000" Configuration_AI_NI9219_Resistance 2.Configuration = "2-Wire" Configuration_AI_NI9219_Resistance 2.CurrentExcitationSource = "Internal" Configuration_AI_NI9219_Resistance 2.CurrentExcitationValue = "0,000500" Configuration_AI_NI9219_Resistance 2.RTD_Type = "Pt3750" Configuration_AI_NI9219_Resistance 2.R0 = "1000,000000" -Configuration_AI_NI9219_Resistance 2.ABC = " 3,81E-3 -6,02E-7 -6E-12" +Configuration_AI_NI9219_Resistance 2.ABC = " 1,224312924E-3 2,308955523E-4 3,938074268E-9" Configuration_AI_NI9219_Resistance 3.Maximum = "250,000000" -Configuration_AI_NI9219_Resistance 3.Minimum = "0,000000" +Configuration_AI_NI9219_Resistance 3.Minimum = "-200,000000" Configuration_AI_NI9219_Resistance 3.Configuration = "2-Wire" Configuration_AI_NI9219_Resistance 3.CurrentExcitationSource = "Internal" Configuration_AI_NI9219_Resistance 3.CurrentExcitationValue = "0,000500" Configuration_AI_NI9219_Resistance 3.RTD_Type = "Pt3750" Configuration_AI_NI9219_Resistance 3.R0 = "1000,000000" Configuration_AI_NI9219_Resistance 3.ABC = " 1,224312924E-3 2,308955523E-4 3,938074268E-9" -Configuration_AI_NI9219_Resistance 4.Maximum = "10500,000000" -Configuration_AI_NI9219_Resistance 4.Minimum = "0,000000" -Configuration_AI_NI9219_Resistance 4.Configuration = "2-Wire" -Configuration_AI_NI9219_Resistance 4.CurrentExcitationSource = "Internal" -Configuration_AI_NI9219_Resistance 4.CurrentExcitationValue = "0,000500" -Configuration_AI_NI9219_Resistance 4.RTD_Type = "Pt3750" -Configuration_AI_NI9219_Resistance 4.R0 = "1000,000000" -Configuration_AI_NI9219_Resistance 4.ABC = " 0,001224 0,000231 3,938074E-9" -Configuration_AI_NI9219_Resistance 5.Maximum = "250,000000" -Configuration_AI_NI9219_Resistance 5.Minimum = "0,000000" -Configuration_AI_NI9219_Resistance 5.Configuration = "2-Wire" -Configuration_AI_NI9219_Resistance 5.CurrentExcitationSource = "Internal" -Configuration_AI_NI9219_Resistance 5.CurrentExcitationValue = "0,000500" -Configuration_AI_NI9219_Resistance 5.RTD_Type = "Pt3750" -Configuration_AI_NI9219_Resistance 5.R0 = "1000,000000" -Configuration_AI_NI9219_Resistance 5.ABC = " 0,001224 0,000231 3,938074E-9" -Configuration_AI_NI9219_Resistance 6.Maximum = "250,000000" -Configuration_AI_NI9219_Resistance 6.Minimum = "0,000000" -Configuration_AI_NI9219_Resistance 6.Configuration = "2-Wire" -Configuration_AI_NI9219_Resistance 6.CurrentExcitationSource = "Internal" -Configuration_AI_NI9219_Resistance 6.CurrentExcitationValue = "0,000500" -Configuration_AI_NI9219_Resistance 6.RTD_Type = "Pt3750" -Configuration_AI_NI9219_Resistance 6.R0 = "1000,000000" -Configuration_AI_NI9219_Resistance 6.ABC = " 0,003810 -6,020000E-7 -6,000000E-12" -Configuration_AI_NI9219_Type. = "7" -Configuration_AI_NI9219_Type 0 = "RTD" -Configuration_AI_NI9219_Type 1 = "Resistance_Thermistor" +Configuration_AI_NI9219_Type. = "4" +Configuration_AI_NI9219_Type 0 = "Thermocouple" +Configuration_AI_NI9219_Type 1 = "Thermocouple" Configuration_AI_NI9219_Type 2 = "Thermocouple" -Configuration_AI_NI9219_Type 3 = "Resistance_RTD" -Configuration_AI_NI9219_Type 4 = "Resistance_RTD" -Configuration_AI_NI9219_Type 5 = "Resistance_RTD" -Configuration_AI_NI9219_Type 6 = "Resistance_RTD" -POS_Config.IP = "10.1.2.1" -POS_Config.Port = "502" -POS_AxesNames. = "3" -POS_AxesNames 0 = "X" -POS_AxesNames 1 = "Y" -POS_AxesNames 2 = "Z" -POS_Reference_Axes = " 1,000000 1,000000 308,000000" -POS_Limits_Axis1 = " 0 155" -POS_Limits_Axis2 = " 0 303" -POS_Limits_Axis3 = " 0 309" -POS_AxesFlipped. = "3" -POS_AxesFlipped 0 = "True" -POS_AxesFlipped 1 = "True" -POS_AxesFlipped 2 = "False" -Pos_MaxVelocity = "300" -Pos_MaxAcceleration = "15000" -Pos_MaxJerk = "140000" -Pos_DO_E-Stop_Index = "0" -Pos_DO_Setup_Index = "2" -ForceLimit_Axis3 = " 0,000000" -ForceLimit_Axis3_Text. = "1" -ForceLimit_Axis3_Text 0 = "" -ForceLimit_Axis3_AO_Limits = " 0,000000 100,000000" -ForceLimit_AI_Index = "0" -AirCooling_AI_Index = "1" -AirCooling_AO_Index = "0" +Configuration_AI_NI9219_Type 3 = "Thermocouple" [DefaultValues] WorkingStroke = "0" @@ -292,7 +202,7 @@ Sensors+ 0 = "True" Sensors+ 1 = "True" Sensors+ 2 = "True" -Sensors+ 3 = "False" +Sensors+ 3 = "True" Sensors+ 4 = "False" Sensors+ 5 = "False" Sensors+ 6 = "False" @@ -330,7 +240,7 @@ [Pathes] User = "C:\Work\CurrentTester\support\User.txt" -ReportsFolder = "C:\Work\CurrentTester\support\ResultData_HSMP2" +ReportsFolder = "C:\Work\CurrentTester\support\ResultData_SMP3" ProtocolsFolder = "\\orion\G K S - Test1\01_Access\Anlagen" CurrentProfilesFolder = "\\orion\labview\CurrentTester\support\CurrentProfiles" Applicants = "C:\Work\CurrentTester\support\Applicants.txt" @@ -351,12 +261,12 @@ ProtocolFolderFormat = "%s_%s_Stromtest" [StateMessages] -Info. = "32" +Info. = "26" Info 0 = "Aktivierter Not-Halt oder eine T�r steht offen! Ein Teststart ist nicht m�glich" Info 1 = "Zum Anlegen eines neuen Tests "Neuer Test" klicken" Info 2 = "Grunddaten anlegen oder bestehenden Test �ffnen" Info 3 = "Testdaten anlegen" -Info 4 = "Zur manuellen Stromeinstellung sollte die Schutzt�renfreigabe aufgehoben werden, zum Verfahren der Achsen sollte der Automatikbetrieb der Anlagensteuerung aktiviert werden!" +Info 4 = "Der Schl�sselschalter muss in die Position "Einrichten" gebracht werden um die Einrichtbuttons zu aktivieren oder in die Position "Automatik" um den Test starten zu k�nnen oder den Strom manuell einzustellen!" Info 5 = "Test geladen" Info 6 = "Laufende Pr�fung..." Info 7 = "Pr�fung erfolgreich abgeschlossen" @@ -378,13 +288,7 @@ Info 23 = "Testbericht erstellt" Info 24 = "Test ist gespeichert" Info 25 = "Testdaten werden ge�ndert... Bitte warten" -Info 26 = "Achsen werden initialisiert..." -Info 27 = "Referenzfahrt l�uft..." -Info 28 = "X-Achse wird referenziert..." -Info 29 = "Y-Achse wird referenziert..." -Info 30 = "Z-Achse wird referenziert..." -Info 31 = "Position wird angefahren..." -Result. = "32" +Result. = "26" Result 0 = "Not-Halt" Result 1 = "" Result 2 = "Bereit" @@ -411,12 +315,6 @@ Result 23 = "Bereit" Result 24 = "Bereit" Result 25 = "Bereit" -Result 26 = "" -Result 27 = "Einrichtbetrieb" -Result 28 = "Einrichtbetrieb" -Result 29 = "Einrichtbetrieb" -Result 30 = "Einrichtbetrieb" -Result 31 = "Einrichtbetrieb" [DialogMessages] Messages. = "13" =================================================================== Cannot display: file marked as a binary type. svn:mime-type = application/octet-stream Index: CurrentTester [LabVIEW]/class_CurrentTester/SubVIs/Protocol_CreateProtocol.vi =================================================================== diff --git a/CurrentTester [LabVIEW]/class_CurrentTester/SubVIs/Protocol_CreateProtocol.vi b/CurrentTester [LabVIEW]/class_CurrentTester/SubVIs/Protocol_CreateProtocol.vi --- a/CurrentTester [LabVIEW]/class_CurrentTester/SubVIs/Protocol_CreateProtocol.vi (revision 65) +++ b/CurrentTester [LabVIEW]/class_CurrentTester/SubVIs/Protocol_CreateProtocol.vi (revision 66) =================================================================== Cannot display: file marked as a binary type. svn:mime-type = application/octet-stream Index: builds/CurrentTester.exe =================================================================== diff --git a/builds/CurrentTester.exe b/builds/CurrentTester.exe --- a/builds/CurrentTester.exe (revision 65) +++ b/builds/CurrentTester.exe (revision 66) =================================================================== Cannot display: file marked as a binary type. svn:mime-type = application/octet-stream Index: builds/data/lib_System.lvlibp =================================================================== diff --git a/builds/data/lib_System.lvlibp b/builds/data/lib_System.lvlibp --- a/builds/data/lib_System.lvlibp (revision 65) +++ b/builds/data/lib_System.lvlibp (revision 66) =================================================================== Cannot display: file marked as a binary type. svn:mime-type = application/octet-stream Index: support/ReportTemplates/ProtocolTemplateGerman.dotx =================================================================== diff --git a/support/ReportTemplates/ProtocolTemplateGerman.dotx b/support/ReportTemplates/ProtocolTemplateGerman.dotx --- a/support/ReportTemplates/ProtocolTemplateGerman.dotx (revision 65) +++ b/support/ReportTemplates/ProtocolTemplateGerman.dotx (revision 66)