Index: CurrentTester [LabVIEW]/CurrentTester.lvproj =================================================================== diff --git a/CurrentTester [LabVIEW]/CurrentTester.lvproj b/CurrentTester [LabVIEW]/CurrentTester.lvproj --- a/CurrentTester [LabVIEW]/CurrentTester.lvproj (revision 65) +++ b/CurrentTester [LabVIEW]/CurrentTester.lvproj (revision 66) @@ -491,135 +491,95 @@ - - - - - - - - - - - - - - - - - + - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + - - - - - - - - - - - - - - - - - + + + + + + + + + + - + + + + + + + + + + + + + - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - + + true Index: CurrentTester [LabVIEW]/Initialization.ini =================================================================== diff --git a/CurrentTester [LabVIEW]/Initialization.ini b/CurrentTester [LabVIEW]/Initialization.ini --- a/CurrentTester [LabVIEW]/Initialization.ini (revision 65) +++ b/CurrentTester [LabVIEW]/Initialization.ini (revision 66) @@ -1,7 +1,7 @@ [Tester] -TesterType = "HSMP2" -TesterName = "Hochstrommessplatz 2" -MaxCurrent = 2000 +TesterType = "SMP3" +TesterName = "Strommessplatz 3" +MaxCurrent = 130 MaxTemperature = 250 MaxAmbientTemperature = 50 TemperatureWarning- = 10 @@ -14,34 +14,34 @@ SensorsEnable 5 = "True" SensorsEnable 6 = "True" SensorsEnable 7 = "True" -SensorsEnable 8 = "True" -SensorsEnable 9 = "True" +SensorsEnable 8 = "False" +SensorsEnable 9 = "False" SensorsEnable 10 = "False" SensorsEnable 11 = "False" SensorsEnable 12 = "False" SensorsEnable 13 = "False" SensorsEnable 14 = "False" SensorsDescription. = "15" -SensorsDescription 0 = "NI-9212: Ch0" -SensorsDescription 1 = "NI-9212: Ch1" -SensorsDescription 2 = "NI-9212: Ch2" -SensorsDescription 3 = "NI-9212: Ch3" -SensorsDescription 4 = "NI-9212: Ch4" -SensorsDescription 5 = "NI-9212: Ch5" -SensorsDescription 6 = "NI-9212: Ch6" -SensorsDescription 7 = "NI-9212: Ch7" -SensorsDescription 8 = "NI-9219_1: Ch0" -SensorsDescription 9 = "NI-9219_1: Ch1" -SensorsDescription 10 = "NI-9219_1: Ch2" -SensorsDescription 11 = "NI-9219_2: Ch0" -SensorsDescription 12 = "NI-9219_2: Ch1" -SensorsDescription 13 = "NI-9219_2: Ch2" -SensorsDescription 14 = "NI-9219_2: Ch3" +SensorsDescription 0 = "NI-9210: Ch0" +SensorsDescription 1 = "NI-9210: Ch1" +SensorsDescription 2 = "NI-9210: Ch2" +SensorsDescription 3 = "NI-9210: Ch3" +SensorsDescription 4 = "NI-9219: Ch0" +SensorsDescription 5 = "NI-9219: Ch1" +SensorsDescription 6 = "NI-9219: Ch2" +SensorsDescription 7 = "NI-9219: Ch3" +SensorsDescription 8 = "" +SensorsDescription 9 = "" +SensorsDescription 10 = "" +SensorsDescription 11 = "" +SensorsDescription 12 = "" +SensorsDescription 13 = "" +SensorsDescription 14 = "" VoltageDescription. = "5 2" -VoltageDescription 0 = "NI-9215: Ch0" +VoltageDescription 0 = "NI PXI-6281: Ch3" VoltageDescription 1 = "Prüflingsspannung [V]" -VoltageDescription 2 = "NI-9219_1: Ch2" -VoltageDescription 3 = "Zero Flux- Spannung [V]" +VoltageDescription 2 = "NI PXI-6281: Ch4" +VoltageDescription 3 = "Shunt- Spannung [V]" VoltageDescription 4 = "" VoltageDescription 5 = "Strom [A]" VoltageDescription 6 = "" @@ -51,235 +51,145 @@ CalibrationPassword = "48c8947f69c054a5caa934674ce8881d02bb18fb59d5a63eeaddff735b0e9801e87294783281ae49fc8287a0fd86779b27d7972d3e84f0fa0d826d7cb67dfefc" [Hardware] -SimulateDevices = False -DI_E-Stop = "" -DI_Setup = "" -PowerSupply_VISAName = "TCPIP0::10.1.2.40::30000::SOCKET" -PowerSupply_Address = "0" -PowerSupply_Baudrate = "0" -PowerSupply_OutputVoltage = "10,000000" -PowerSupply_OverVoltageProtection = "9,800000" +SimulateDevices = True +DI_E-Stop = "PXI1Slot5/port0/line5" +DI_Setup = "PXI1Slot5/port0/line4" +PowerSupply_VISAName = "COM4" +PowerSupply_Address = "1" +PowerSupply_Baudrate = "9600" +PowerSupply_OutputVoltage = "5,500000" +PowerSupply_OverVoltageProtection = "6,000000" PowerSupply_MinCurrent = "0" PowerSupply_Check = False -PowerSupply_WarningPower = "4000,000000" -PowerSupply_AbortPower = "5000,000000" -PowerSupply_PID = "FALSE" -PowerSupply_PID_Time = "1,000000" +PowerSupply_WarningPower = "200,000000" +PowerSupply_AbortPower = "250,000000" +PowerSupply_PID = "False" +PowerSupply_PID_Time = "0,100000" PowerSupply_PID_ProportionalGain = "0,100000" PowerSupply_PID_IntegralTime = "0,180000" PowerSupply_PID_DerivativeTime = "0,000000" -AbortCurrentDifference = "0,000000" +AbortCurrentDifference = "50" Measurement_Channels. = "17" -Measurement_Channels 0 = "NI9215/ai0" -Measurement_Channels 1 = "NI9219_1/ai2" -Measurement_Channels 2 = "NI9212/ai0" -Measurement_Channels 3 = "NI9212/ai1" -Measurement_Channels 4 = "NI9212/ai2" -Measurement_Channels 5 = "NI9212/ai3" -Measurement_Channels 6 = "NI9212/ai4" -Measurement_Channels 7 = "NI9212/ai5" -Measurement_Channels 8 = "NI9212/ai6" -Measurement_Channels 9 = "NI9212/ai7" -Measurement_Channels 10 = "NI9219_1/ai0" -Measurement_Channels 11 = "NI9219_1/ai1" -Measurement_Channels 12 = "NI9219_1/ai2" -Measurement_Channels 13 = "NI9219_2/ai0" -Measurement_Channels 14 = "NI9219_2/ai1" -Measurement_Channels 15 = "NI9219_2/ai2" -Measurement_Channels 16 = "NI9219_2/ai3" -Measurement_Sample = " 40,000000 40,000000 2,000000 2,000000 2,000000 2,000000 2,000000 2,000000 2,000000 2,000000 40,000000 40,000000 40,000000 40,000000 40,000000 40,000000 40,000000" -ShuntResistance = "0,005" +Measurement_Channels 0 = "PXI1Slot5/ai4" +Measurement_Channels 1 = "PXI1Slot5/ai5" +Measurement_Channels 2 = "NI9210/ai0" +Measurement_Channels 3 = "NI9210/ai1" +Measurement_Channels 4 = "NI9210/ai2" +Measurement_Channels 5 = "NI9210/ai3" +Measurement_Channels 6 = "NI9219/ai0" +Measurement_Channels 7 = "NI9219/ai1" +Measurement_Channels 8 = "NI9219/ai2" +Measurement_Channels 9 = "NI9219/ai3" +Measurement_Channels 10 = "" +Measurement_Channels 11 = "" +Measurement_Channels 12 = "" +Measurement_Channels 13 = "" +Measurement_Channels 14 = "" +Measurement_Channels 15 = "" +Measurement_Channels 16 = "" +Measurement_Sample = " 1,000000 1,000000 2,000000 2,000000 2,000000 2,000000 40,000000 40,000000 40,000000 40,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000" +ShuntResistance = 0,001 Measurement_Check = False Measurement_Delay = "1" -DMM_VISAName = "NI9219_1/ai3" -DMM_ContactLimits = " 0,000000 10,000000" +DMM_VISAName = "PXI1Slot3" +DMM_ContactLimits = " 0,0 1,0" TemperatureGain = " 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000" TemperatureOffset = " 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000" -VoltageGain = " 1,000000 -1,000000 1,000000 1,000000 1,000000" +VoltageGain = " 1,000000 1,000000 1,000000 1,000000 1,000000" VoltageOffset = " 0,000000 0,000000 0,000000 0,000000 0,000000" AllowedContactFails = "2" -[HSMP2] -DMM_Configuration.Maximum = "10500,000000" -DMM_Configuration.Minimum = "0,000000" -DMM_Configuration.Configuration = "4-Wire" -DMM_Configuration.CurrentExcitationSource = "Internal" -DMM_Configuration.CurrentExcitationValue = "0,000500" -DMM_Sample = "40,000000" +[SMP3] +DMM_Function = "2-wire Resistance" +DMM_AutoRange = False +DMM_Range = "0,020000" +DMM_Resolution = "0,001000" Configuration_AI_Voltage. = "2" -Configuration_AI_Voltage 0.Maximum = "10,000000" -Configuration_AI_Voltage 0.Minimum = "-10,000000" +Configuration_AI_Voltage 0.Maximum = "5,000000" +Configuration_AI_Voltage 0.Minimum = "-5,000000" Configuration_AI_Voltage 0.InputTerminalConfiguration = "Differential" -Configuration_AI_Voltage 1.Maximum = "10,000000" -Configuration_AI_Voltage 1.Minimum = "0,000000" +Configuration_AI_Voltage 1.Maximum = "1,000000" +Configuration_AI_Voltage 1.Minimum = "-1,000000" Configuration_AI_Voltage 1.InputTerminalConfiguration = "Differential" -Configuration_AI_Thermocouple. = "15" +Configuration_AI_Thermocouple. = "8" Configuration_AI_Thermocouple 0.Maximum = "250,000000" -Configuration_AI_Thermocouple 0.Minimum = "0,000000" +Configuration_AI_Thermocouple 0.Minimum = "-200,000000" Configuration_AI_Thermocouple 0.Type = "K" Configuration_AI_Thermocouple 0.CJC_Source = "Built-In" Configuration_AI_Thermocouple 0.CJC_Value = "25,000000" Configuration_AI_Thermocouple 1.Maximum = "250,000000" -Configuration_AI_Thermocouple 1.Minimum = "0,000000" +Configuration_AI_Thermocouple 1.Minimum = "-200,000000" Configuration_AI_Thermocouple 1.Type = "K" Configuration_AI_Thermocouple 1.CJC_Source = "Built-In" Configuration_AI_Thermocouple 1.CJC_Value = "25,000000" Configuration_AI_Thermocouple 2.Maximum = "250,000000" -Configuration_AI_Thermocouple 2.Minimum = "0,000000" +Configuration_AI_Thermocouple 2.Minimum = "-200,000000" Configuration_AI_Thermocouple 2.Type = "K" Configuration_AI_Thermocouple 2.CJC_Source = "Built-In" Configuration_AI_Thermocouple 2.CJC_Value = "25,000000" Configuration_AI_Thermocouple 3.Maximum = "250,000000" -Configuration_AI_Thermocouple 3.Minimum = "0,000000" +Configuration_AI_Thermocouple 3.Minimum = "-200,000000" Configuration_AI_Thermocouple 3.Type = "K" Configuration_AI_Thermocouple 3.CJC_Source = "Built-In" Configuration_AI_Thermocouple 3.CJC_Value = "10,000000" Configuration_AI_Thermocouple 4.Maximum = "250,000000" -Configuration_AI_Thermocouple 4.Minimum = "0,000000" +Configuration_AI_Thermocouple 4.Minimum = "-200,000000" Configuration_AI_Thermocouple 4.Type = "K" Configuration_AI_Thermocouple 4.CJC_Source = "Built-In" Configuration_AI_Thermocouple 4.CJC_Value = "25,000000" Configuration_AI_Thermocouple 5.Maximum = "250,000000" -Configuration_AI_Thermocouple 5.Minimum = "0,000000" +Configuration_AI_Thermocouple 5.Minimum = "-200,000000" Configuration_AI_Thermocouple 5.Type = "K" Configuration_AI_Thermocouple 5.CJC_Source = "Built-In" Configuration_AI_Thermocouple 5.CJC_Value = "25,000000" Configuration_AI_Thermocouple 6.Maximum = "250,000000" -Configuration_AI_Thermocouple 6.Minimum = "0,000000" +Configuration_AI_Thermocouple 6.Minimum = "-200,000000" Configuration_AI_Thermocouple 6.Type = "K" Configuration_AI_Thermocouple 6.CJC_Source = "Built-In" Configuration_AI_Thermocouple 6.CJC_Value = "25,000000" Configuration_AI_Thermocouple 7.Maximum = "250,000000" -Configuration_AI_Thermocouple 7.Minimum = "0,000000" +Configuration_AI_Thermocouple 7.Minimum = "-200,000000" Configuration_AI_Thermocouple 7.Type = "K" Configuration_AI_Thermocouple 7.CJC_Source = "Built-In" Configuration_AI_Thermocouple 7.CJC_Value = "25,000000" -Configuration_AI_Thermocouple 8.Maximum = "250,000000" -Configuration_AI_Thermocouple 8.Minimum = "0,000000" -Configuration_AI_Thermocouple 8.Type = "K" -Configuration_AI_Thermocouple 8.CJC_Source = "Built-In" -Configuration_AI_Thermocouple 8.CJC_Value = "25,000000" -Configuration_AI_Thermocouple 9.Maximum = "250,000000" -Configuration_AI_Thermocouple 9.Minimum = "0,000000" -Configuration_AI_Thermocouple 9.Type = "K" -Configuration_AI_Thermocouple 9.CJC_Source = "Built-In" -Configuration_AI_Thermocouple 9.CJC_Value = "25,000000" -Configuration_AI_Thermocouple 10.Maximum = "250,000000" -Configuration_AI_Thermocouple 10.Minimum = "0,000000" -Configuration_AI_Thermocouple 10.Type = "K" -Configuration_AI_Thermocouple 10.CJC_Source = "Built-In" -Configuration_AI_Thermocouple 10.CJC_Value = "25,000000" -Configuration_AI_Thermocouple 11.Maximum = "250,000000" -Configuration_AI_Thermocouple 11.Minimum = "-200,000000" -Configuration_AI_Thermocouple 11.Type = "K" -Configuration_AI_Thermocouple 11.CJC_Source = "Built-In" -Configuration_AI_Thermocouple 11.CJC_Value = "25,000000" -Configuration_AI_Thermocouple 12.Maximum = "250,000000" -Configuration_AI_Thermocouple 12.Minimum = "-200,000000" -Configuration_AI_Thermocouple 12.Type = "K" -Configuration_AI_Thermocouple 12.CJC_Source = "Built-In" -Configuration_AI_Thermocouple 12.CJC_Value = "25,000000" -Configuration_AI_Thermocouple 13.Maximum = "250,000000" -Configuration_AI_Thermocouple 13.Minimum = "-200,000000" -Configuration_AI_Thermocouple 13.Type = "K" -Configuration_AI_Thermocouple 13.CJC_Source = "Built-In" -Configuration_AI_Thermocouple 13.CJC_Value = "10,000000" -Configuration_AI_Thermocouple 14.Maximum = "250,000000" -Configuration_AI_Thermocouple 14.Minimum = "-200,000000" -Configuration_AI_Thermocouple 14.Type = "K" -Configuration_AI_Thermocouple 14.CJC_Source = "Built-In" -Configuration_AI_Thermocouple 14.CJC_Value = "25,000000" -Configuration_AI_NI9219_Resistance. = "7" -Configuration_AI_NI9219_Resistance 0.Maximum = "800,000000" +Configuration_AI_NI9219_Resistance. = "4" +Configuration_AI_NI9219_Resistance 0.Maximum = "10500,000000" Configuration_AI_NI9219_Resistance 0.Minimum = "0,000000" -Configuration_AI_NI9219_Resistance 0.Configuration = "4-Wire" +Configuration_AI_NI9219_Resistance 0.Configuration = "2-Wire" Configuration_AI_NI9219_Resistance 0.CurrentExcitationSource = "Internal" Configuration_AI_NI9219_Resistance 0.CurrentExcitationValue = "0,000500" Configuration_AI_NI9219_Resistance 0.RTD_Type = "Pt3750" Configuration_AI_NI9219_Resistance 0.R0 = "1000,000000" -Configuration_AI_NI9219_Resistance 0.ABC = " 1,224E-3 2,31E-4 3,938074E-9" +Configuration_AI_NI9219_Resistance 0.ABC = " 1,224312924E-3 2,308955523E-4 3,938074268E-9" Configuration_AI_NI9219_Resistance 1.Maximum = "250,000000" -Configuration_AI_NI9219_Resistance 1.Minimum = "0,000000" +Configuration_AI_NI9219_Resistance 1.Minimum = "-200,000000" Configuration_AI_NI9219_Resistance 1.Configuration = "2-Wire" Configuration_AI_NI9219_Resistance 1.CurrentExcitationSource = "Internal" Configuration_AI_NI9219_Resistance 1.CurrentExcitationValue = "0,000500" Configuration_AI_NI9219_Resistance 1.RTD_Type = "Pt3750" Configuration_AI_NI9219_Resistance 1.R0 = "1000,000000" -Configuration_AI_NI9219_Resistance 1.ABC = " 1,224E-3 2,31E-4 3,938074E-9" +Configuration_AI_NI9219_Resistance 1.ABC = " 1,224312924E-3 2,308955523E-4 3,938074268E-9" Configuration_AI_NI9219_Resistance 2.Maximum = "250,000000" -Configuration_AI_NI9219_Resistance 2.Minimum = "0,000000" +Configuration_AI_NI9219_Resistance 2.Minimum = "-200,000000" Configuration_AI_NI9219_Resistance 2.Configuration = "2-Wire" Configuration_AI_NI9219_Resistance 2.CurrentExcitationSource = "Internal" Configuration_AI_NI9219_Resistance 2.CurrentExcitationValue = "0,000500" Configuration_AI_NI9219_Resistance 2.RTD_Type = "Pt3750" Configuration_AI_NI9219_Resistance 2.R0 = "1000,000000" -Configuration_AI_NI9219_Resistance 2.ABC = " 3,81E-3 -6,02E-7 -6E-12" +Configuration_AI_NI9219_Resistance 2.ABC = " 1,224312924E-3 2,308955523E-4 3,938074268E-9" Configuration_AI_NI9219_Resistance 3.Maximum = "250,000000" -Configuration_AI_NI9219_Resistance 3.Minimum = "0,000000" +Configuration_AI_NI9219_Resistance 3.Minimum = "-200,000000" Configuration_AI_NI9219_Resistance 3.Configuration = "2-Wire" Configuration_AI_NI9219_Resistance 3.CurrentExcitationSource = "Internal" Configuration_AI_NI9219_Resistance 3.CurrentExcitationValue = "0,000500" Configuration_AI_NI9219_Resistance 3.RTD_Type = "Pt3750" Configuration_AI_NI9219_Resistance 3.R0 = "1000,000000" Configuration_AI_NI9219_Resistance 3.ABC = " 1,224312924E-3 2,308955523E-4 3,938074268E-9" -Configuration_AI_NI9219_Resistance 4.Maximum = "10500,000000" -Configuration_AI_NI9219_Resistance 4.Minimum = "0,000000" -Configuration_AI_NI9219_Resistance 4.Configuration = "2-Wire" -Configuration_AI_NI9219_Resistance 4.CurrentExcitationSource = "Internal" -Configuration_AI_NI9219_Resistance 4.CurrentExcitationValue = "0,000500" -Configuration_AI_NI9219_Resistance 4.RTD_Type = "Pt3750" -Configuration_AI_NI9219_Resistance 4.R0 = "1000,000000" -Configuration_AI_NI9219_Resistance 4.ABC = " 0,001224 0,000231 3,938074E-9" -Configuration_AI_NI9219_Resistance 5.Maximum = "250,000000" -Configuration_AI_NI9219_Resistance 5.Minimum = "0,000000" -Configuration_AI_NI9219_Resistance 5.Configuration = "2-Wire" -Configuration_AI_NI9219_Resistance 5.CurrentExcitationSource = "Internal" -Configuration_AI_NI9219_Resistance 5.CurrentExcitationValue = "0,000500" -Configuration_AI_NI9219_Resistance 5.RTD_Type = "Pt3750" -Configuration_AI_NI9219_Resistance 5.R0 = "1000,000000" -Configuration_AI_NI9219_Resistance 5.ABC = " 0,001224 0,000231 3,938074E-9" -Configuration_AI_NI9219_Resistance 6.Maximum = "250,000000" -Configuration_AI_NI9219_Resistance 6.Minimum = "0,000000" -Configuration_AI_NI9219_Resistance 6.Configuration = "2-Wire" -Configuration_AI_NI9219_Resistance 6.CurrentExcitationSource = "Internal" -Configuration_AI_NI9219_Resistance 6.CurrentExcitationValue = "0,000500" -Configuration_AI_NI9219_Resistance 6.RTD_Type = "Pt3750" -Configuration_AI_NI9219_Resistance 6.R0 = "1000,000000" -Configuration_AI_NI9219_Resistance 6.ABC = " 0,003810 -6,020000E-7 -6,000000E-12" -Configuration_AI_NI9219_Type. = "7" -Configuration_AI_NI9219_Type 0 = "RTD" -Configuration_AI_NI9219_Type 1 = "Resistance_Thermistor" +Configuration_AI_NI9219_Type. = "4" +Configuration_AI_NI9219_Type 0 = "Thermocouple" +Configuration_AI_NI9219_Type 1 = "Thermocouple" Configuration_AI_NI9219_Type 2 = "Thermocouple" -Configuration_AI_NI9219_Type 3 = "Resistance_RTD" -Configuration_AI_NI9219_Type 4 = "Resistance_RTD" -Configuration_AI_NI9219_Type 5 = "Resistance_RTD" -Configuration_AI_NI9219_Type 6 = "Resistance_RTD" -POS_Config.IP = "10.1.2.1" -POS_Config.Port = "502" -POS_AxesNames. = "3" -POS_AxesNames 0 = "X" -POS_AxesNames 1 = "Y" -POS_AxesNames 2 = "Z" -POS_Reference_Axes = " 1,000000 1,000000 308,000000" -POS_Limits_Axis1 = " 0 155" -POS_Limits_Axis2 = " 0 303" -POS_Limits_Axis3 = " 0 309" -POS_AxesFlipped. = "3" -POS_AxesFlipped 0 = "True" -POS_AxesFlipped 1 = "True" -POS_AxesFlipped 2 = "False" -Pos_MaxVelocity = "300" -Pos_MaxAcceleration = "15000" -Pos_MaxJerk = "140000" -Pos_DO_E-Stop_Index = "0" -Pos_DO_Setup_Index = "2" -ForceLimit_Axis3 = " 0,000000" -ForceLimit_Axis3_Text. = "1" -ForceLimit_Axis3_Text 0 = "" -ForceLimit_Axis3_AO_Limits = " 0,000000 100,000000" -ForceLimit_AI_Index = "0" -AirCooling_AI_Index = "1" -AirCooling_AO_Index = "0" +Configuration_AI_NI9219_Type 3 = "Thermocouple" [DefaultValues] WorkingStroke = "0" @@ -292,7 +202,7 @@ Sensors+ 0 = "True" Sensors+ 1 = "True" Sensors+ 2 = "True" -Sensors+ 3 = "False" +Sensors+ 3 = "True" Sensors+ 4 = "False" Sensors+ 5 = "False" Sensors+ 6 = "False" @@ -330,7 +240,7 @@ [Pathes] User = "C:\Work\CurrentTester\support\User.txt" -ReportsFolder = "C:\Work\CurrentTester\support\ResultData_HSMP2" +ReportsFolder = "C:\Work\CurrentTester\support\ResultData_SMP3" ProtocolsFolder = "\\orion\G K S - Test1\01_Access\Anlagen" CurrentProfilesFolder = "\\orion\labview\CurrentTester\support\CurrentProfiles" Applicants = "C:\Work\CurrentTester\support\Applicants.txt" @@ -351,12 +261,12 @@ ProtocolFolderFormat = "%s_%s_Stromtest" [StateMessages] -Info. = "32" +Info. = "26" Info 0 = "Aktivierter Not-Halt oder eine Tür steht offen! Ein Teststart ist nicht möglich" Info 1 = "Zum Anlegen eines neuen Tests "Neuer Test" klicken" Info 2 = "Grunddaten anlegen oder bestehenden Test öffnen" Info 3 = "Testdaten anlegen" -Info 4 = "Zur manuellen Stromeinstellung sollte die Schutztürenfreigabe aufgehoben werden, zum Verfahren der Achsen sollte der Automatikbetrieb der Anlagensteuerung aktiviert werden!" +Info 4 = "Der Schlüsselschalter muss in die Position "Einrichten" gebracht werden um die Einrichtbuttons zu aktivieren oder in die Position "Automatik" um den Test starten zu können oder den Strom manuell einzustellen!" Info 5 = "Test geladen" Info 6 = "Laufende Prüfung..." Info 7 = "Prüfung erfolgreich abgeschlossen" @@ -378,13 +288,7 @@ Info 23 = "Testbericht erstellt" Info 24 = "Test ist gespeichert" Info 25 = "Testdaten werden geändert... Bitte warten" -Info 26 = "Achsen werden initialisiert..." -Info 27 = "Referenzfahrt läuft..." -Info 28 = "X-Achse wird referenziert..." -Info 29 = "Y-Achse wird referenziert..." -Info 30 = "Z-Achse wird referenziert..." -Info 31 = "Position wird angefahren..." -Result. = "32" +Result. = "26" Result 0 = "Not-Halt" Result 1 = "" Result 2 = "Bereit" @@ -411,12 +315,6 @@ Result 23 = "Bereit" Result 24 = "Bereit" Result 25 = "Bereit" -Result 26 = "" -Result 27 = "Einrichtbetrieb" -Result 28 = "Einrichtbetrieb" -Result 29 = "Einrichtbetrieb" -Result 30 = "Einrichtbetrieb" -Result 31 = "Einrichtbetrieb" [DialogMessages] Messages. = "13" =================================================================== Cannot display: file marked as a binary type. svn:mime-type = application/octet-stream Index: CurrentTester [LabVIEW]/class_CurrentTester/SubVIs/Protocol_CreateProtocol.vi =================================================================== diff --git a/CurrentTester [LabVIEW]/class_CurrentTester/SubVIs/Protocol_CreateProtocol.vi b/CurrentTester [LabVIEW]/class_CurrentTester/SubVIs/Protocol_CreateProtocol.vi --- a/CurrentTester [LabVIEW]/class_CurrentTester/SubVIs/Protocol_CreateProtocol.vi (revision 65) +++ b/CurrentTester [LabVIEW]/class_CurrentTester/SubVIs/Protocol_CreateProtocol.vi (revision 66) =================================================================== Cannot display: file marked as a binary type. svn:mime-type = application/octet-stream Index: builds/CurrentTester.exe =================================================================== diff --git a/builds/CurrentTester.exe b/builds/CurrentTester.exe --- a/builds/CurrentTester.exe (revision 65) +++ b/builds/CurrentTester.exe (revision 66) =================================================================== Cannot display: file marked as a binary type. svn:mime-type = application/octet-stream Index: builds/data/lib_System.lvlibp =================================================================== diff --git a/builds/data/lib_System.lvlibp b/builds/data/lib_System.lvlibp --- a/builds/data/lib_System.lvlibp (revision 65) +++ b/builds/data/lib_System.lvlibp (revision 66) =================================================================== Cannot display: file marked as a binary type. svn:mime-type = application/octet-stream Index: support/ReportTemplates/ProtocolTemplateGerman.dotx =================================================================== diff --git a/support/ReportTemplates/ProtocolTemplateGerman.dotx b/support/ReportTemplates/ProtocolTemplateGerman.dotx --- a/support/ReportTemplates/ProtocolTemplateGerman.dotx (revision 65) +++ b/support/ReportTemplates/ProtocolTemplateGerman.dotx (revision 66)