Initialization_HSMP2.ini
440 lines
| 21.1 KiB
| text/x-ini
|
IniLexer
| r37 | [Tester] | ||
| TesterType = "HSMP2" | |||
| TesterName = "Hochstrommessplatz 2" | |||
| r56 | MaxCurrent = 2000 | ||
| r37 | MaxTemperature = 250 | ||
| r44 | MaxAmbientTemperature = 50 | ||
| r52 | TemperatureWarning- = 10 | ||
| r41 | SensorsEnable.<size(s)> = "15" | ||
| r37 | SensorsEnable 0 = "True" | ||
| SensorsEnable 1 = "True" | |||
| SensorsEnable 2 = "True" | |||
| SensorsEnable 3 = "True" | |||
| SensorsEnable 4 = "True" | |||
| SensorsEnable 5 = "True" | |||
| SensorsEnable 6 = "True" | |||
| r53 | SensorsEnable 7 = "True" | ||
| SensorsEnable 8 = "True" | |||
| SensorsEnable 9 = "True" | |||
| r54 | SensorsEnable 10 = "False" | ||
| r41 | SensorsEnable 11 = "False" | ||
| SensorsEnable 12 = "False" | |||
| SensorsEnable 13 = "False" | |||
| SensorsEnable 14 = "False" | |||
| SensorsDescription.<size(s)> = "15" | |||
| r55 | SensorsDescription 0 = "NI-9212: Ch0" | ||
| SensorsDescription 1 = "NI-9212: Ch1" | |||
| SensorsDescription 2 = "NI-9212: Ch2" | |||
| SensorsDescription 3 = "NI-9212: Ch3" | |||
| SensorsDescription 4 = "NI-9212: Ch4" | |||
| SensorsDescription 5 = "NI-9212: Ch5" | |||
| SensorsDescription 6 = "NI-9212: Ch6" | |||
| SensorsDescription 7 = "NI-9212: Ch7" | |||
| SensorsDescription 8 = "NI-9219_1: Ch0" | |||
| SensorsDescription 9 = "NI-9219_1: Ch1" | |||
| SensorsDescription 10 = "NI-9219_1: Ch2" | |||
| SensorsDescription 11 = "NI-9219_2: Ch0" | |||
| SensorsDescription 12 = "NI-9219_2: Ch1" | |||
| SensorsDescription 13 = "NI-9219_2: Ch2" | |||
| SensorsDescription 14 = "NI-9219_2: Ch3" | |||
| r48 | VoltageDescription.<size(s)> = "5 2" | ||
| r55 | VoltageDescription 0 = "NI-9215: Ch0" | ||
| r37 | VoltageDescription 1 = "Pr�flingsspannung [V]" | ||
| r55 | VoltageDescription 2 = "NI-9219_1: Ch2" | ||
| r37 | VoltageDescription 3 = "Zero Flux- Spannung [V]" | ||
| VoltageDescription 4 = "" | |||
| VoltageDescription 5 = "Strom [A]" | |||
| VoltageDescription 6 = "" | |||
| VoltageDescription 7 = "Widerstand [mOhm]" | |||
| r48 | VoltageDescription 8 = "" | ||
| VoltageDescription 9 = "Leistung [W]" | |||
| r37 | CalibrationPassword = "48c8947f69c054a5caa934674ce8881d02bb18fb59d5a63eeaddff735b0e9801e87294783281ae49fc8287a0fd86779b27d7972d3e84f0fa0d826d7cb67dfefc" | ||
| [Hardware] | |||
| SimulateDevices = False | |||
| DI_E-Stop = "" | |||
| DI_Setup = "" | |||
| r52 | PowerSupply_VISAName = "TCPIP0::10.1.2.40::30000::SOCKET" | ||
| r37 | PowerSupply_Address = "0" | ||
| r52 | PowerSupply_Baudrate = "0" | ||
| r39 | PowerSupply_OutputVoltage = "10,000000" | ||
| PowerSupply_OverVoltageProtection = "9,800000" | |||
| r37 | PowerSupply_MinCurrent = "0" | ||
| PowerSupply_Check = False | |||
| r56 | PowerSupply_WarningPower = "4000,000000" | ||
| PowerSupply_AbortPower = "5000,000000" | |||
| r37 | PowerSupply_PID = "FALSE" | ||
| r54 | PowerSupply_PID_Time = "1,000000" | ||
| r37 | PowerSupply_PID_ProportionalGain = "0,100000" | ||
| PowerSupply_PID_IntegralTime = "0,180000" | |||
| PowerSupply_PID_DerivativeTime = "0,000000" | |||
| AbortCurrentDifference = "0,000000" | |||
| r53 | Measurement_Channels.<size(s)> = "17" | ||
| r37 | Measurement_Channels 0 = "NI9215/ai0" | ||
| r54 | Measurement_Channels 1 = "NI9219_1/ai2" | ||
| r37 | Measurement_Channels 2 = "NI9212/ai0" | ||
| Measurement_Channels 3 = "NI9212/ai1" | |||
| Measurement_Channels 4 = "NI9212/ai2" | |||
| Measurement_Channels 5 = "NI9212/ai3" | |||
| r53 | Measurement_Channels 6 = "NI9212/ai4" | ||
| Measurement_Channels 7 = "NI9212/ai5" | |||
| Measurement_Channels 8 = "NI9212/ai6" | |||
| Measurement_Channels 9 = "NI9212/ai7" | |||
| Measurement_Channels 10 = "NI9219_1/ai0" | |||
| Measurement_Channels 11 = "NI9219_1/ai1" | |||
| Measurement_Channels 12 = "NI9219_1/ai2" | |||
| Measurement_Channels 13 = "NI9219_2/ai0" | |||
| Measurement_Channels 14 = "NI9219_2/ai1" | |||
| Measurement_Channels 15 = "NI9219_2/ai2" | |||
| Measurement_Channels 16 = "NI9219_2/ai3" | |||
| Measurement_Sample = "<size(s)=17> 40,000000 40,000000 2,000000 2,000000 2,000000 2,000000 2,000000 2,000000 2,000000 2,000000 40,000000 40,000000 40,000000 40,000000 40,000000 40,000000 40,000000" | |||
| r37 | ShuntResistance = "0,005" | ||
| Measurement_Check = False | |||
| r54 | Measurement_Delay = "1" | ||
| r41 | DMM_VISAName = "NI9219_1/ai3" | ||
| r66 | DMM_ContactLimits = "<size(s)=2> -1,000000 1,000000" | ||
| r41 | TemperatureGain = "<size(s)=15> 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000" | ||
| TemperatureOffset = "<size(s)=15> 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000" | |||
| r54 | VoltageGain = "<size(s)=5> 1,000000 -1,000000 1,000000 1,000000 1,000000" | ||
| r48 | VoltageOffset = "<size(s)=5> 0,000000 0,000000 0,000000 0,000000 0,000000" | ||
| r37 | AllowedContactFails = "2" | ||
| [HSMP2] | |||
| r53 | DMM_Configuration.Maximum = "10500,000000" | ||
| r41 | DMM_Configuration.Minimum = "0,000000" | ||
| r53 | DMM_Configuration.Configuration = "4-Wire" | ||
| r37 | DMM_Configuration.CurrentExcitationSource = "Internal" | ||
| r41 | DMM_Configuration.CurrentExcitationValue = "0,000500" | ||
| r49 | DMM_Sample = "40,000000" | ||
| r37 | Configuration_AI_Voltage.<size(s)> = "2" | ||
| Configuration_AI_Voltage 0.Maximum = "10,000000" | |||
| Configuration_AI_Voltage 0.Minimum = "-10,000000" | |||
| Configuration_AI_Voltage 0.InputTerminalConfiguration = "Differential" | |||
| Configuration_AI_Voltage 1.Maximum = "10,000000" | |||
| Configuration_AI_Voltage 1.Minimum = "0,000000" | |||
| Configuration_AI_Voltage 1.InputTerminalConfiguration = "Differential" | |||
| r41 | Configuration_AI_Thermocouple.<size(s)> = "15" | ||
| r37 | Configuration_AI_Thermocouple 0.Maximum = "250,000000" | ||
| r53 | Configuration_AI_Thermocouple 0.Minimum = "0,000000" | ||
| r37 | Configuration_AI_Thermocouple 0.Type = "K" | ||
| Configuration_AI_Thermocouple 0.CJC_Source = "Built-In" | |||
| Configuration_AI_Thermocouple 0.CJC_Value = "25,000000" | |||
| Configuration_AI_Thermocouple 1.Maximum = "250,000000" | |||
| r53 | Configuration_AI_Thermocouple 1.Minimum = "0,000000" | ||
| r37 | Configuration_AI_Thermocouple 1.Type = "K" | ||
| Configuration_AI_Thermocouple 1.CJC_Source = "Built-In" | |||
| Configuration_AI_Thermocouple 1.CJC_Value = "25,000000" | |||
| Configuration_AI_Thermocouple 2.Maximum = "250,000000" | |||
| r53 | Configuration_AI_Thermocouple 2.Minimum = "0,000000" | ||
| r37 | Configuration_AI_Thermocouple 2.Type = "K" | ||
| Configuration_AI_Thermocouple 2.CJC_Source = "Built-In" | |||
| Configuration_AI_Thermocouple 2.CJC_Value = "25,000000" | |||
| Configuration_AI_Thermocouple 3.Maximum = "250,000000" | |||
| r53 | Configuration_AI_Thermocouple 3.Minimum = "0,000000" | ||
| r37 | Configuration_AI_Thermocouple 3.Type = "K" | ||
| Configuration_AI_Thermocouple 3.CJC_Source = "Built-In" | |||
| Configuration_AI_Thermocouple 3.CJC_Value = "10,000000" | |||
| Configuration_AI_Thermocouple 4.Maximum = "250,000000" | |||
| r53 | Configuration_AI_Thermocouple 4.Minimum = "0,000000" | ||
| r37 | Configuration_AI_Thermocouple 4.Type = "K" | ||
| Configuration_AI_Thermocouple 4.CJC_Source = "Built-In" | |||
| Configuration_AI_Thermocouple 4.CJC_Value = "25,000000" | |||
| Configuration_AI_Thermocouple 5.Maximum = "250,000000" | |||
| r53 | Configuration_AI_Thermocouple 5.Minimum = "0,000000" | ||
| r37 | Configuration_AI_Thermocouple 5.Type = "K" | ||
| Configuration_AI_Thermocouple 5.CJC_Source = "Built-In" | |||
| Configuration_AI_Thermocouple 5.CJC_Value = "25,000000" | |||
| Configuration_AI_Thermocouple 6.Maximum = "250,000000" | |||
| r53 | Configuration_AI_Thermocouple 6.Minimum = "0,000000" | ||
| r37 | Configuration_AI_Thermocouple 6.Type = "K" | ||
| Configuration_AI_Thermocouple 6.CJC_Source = "Built-In" | |||
| Configuration_AI_Thermocouple 6.CJC_Value = "25,000000" | |||
| Configuration_AI_Thermocouple 7.Maximum = "250,000000" | |||
| r53 | Configuration_AI_Thermocouple 7.Minimum = "0,000000" | ||
| r37 | Configuration_AI_Thermocouple 7.Type = "K" | ||
| Configuration_AI_Thermocouple 7.CJC_Source = "Built-In" | |||
| Configuration_AI_Thermocouple 7.CJC_Value = "25,000000" | |||
| Configuration_AI_Thermocouple 8.Maximum = "250,000000" | |||
| r53 | Configuration_AI_Thermocouple 8.Minimum = "0,000000" | ||
| r37 | Configuration_AI_Thermocouple 8.Type = "K" | ||
| Configuration_AI_Thermocouple 8.CJC_Source = "Built-In" | |||
| Configuration_AI_Thermocouple 8.CJC_Value = "25,000000" | |||
| Configuration_AI_Thermocouple 9.Maximum = "250,000000" | |||
| r53 | Configuration_AI_Thermocouple 9.Minimum = "0,000000" | ||
| r37 | Configuration_AI_Thermocouple 9.Type = "K" | ||
| Configuration_AI_Thermocouple 9.CJC_Source = "Built-In" | |||
| Configuration_AI_Thermocouple 9.CJC_Value = "25,000000" | |||
| r41 | Configuration_AI_Thermocouple 10.Maximum = "250,000000" | ||
| r53 | Configuration_AI_Thermocouple 10.Minimum = "0,000000" | ||
| r41 | Configuration_AI_Thermocouple 10.Type = "K" | ||
| Configuration_AI_Thermocouple 10.CJC_Source = "Built-In" | |||
| Configuration_AI_Thermocouple 10.CJC_Value = "25,000000" | |||
| Configuration_AI_Thermocouple 11.Maximum = "250,000000" | |||
| Configuration_AI_Thermocouple 11.Minimum = "-200,000000" | |||
| Configuration_AI_Thermocouple 11.Type = "K" | |||
| Configuration_AI_Thermocouple 11.CJC_Source = "Built-In" | |||
| Configuration_AI_Thermocouple 11.CJC_Value = "25,000000" | |||
| Configuration_AI_Thermocouple 12.Maximum = "250,000000" | |||
| Configuration_AI_Thermocouple 12.Minimum = "-200,000000" | |||
| Configuration_AI_Thermocouple 12.Type = "K" | |||
| Configuration_AI_Thermocouple 12.CJC_Source = "Built-In" | |||
| Configuration_AI_Thermocouple 12.CJC_Value = "25,000000" | |||
| Configuration_AI_Thermocouple 13.Maximum = "250,000000" | |||
| Configuration_AI_Thermocouple 13.Minimum = "-200,000000" | |||
| Configuration_AI_Thermocouple 13.Type = "K" | |||
| Configuration_AI_Thermocouple 13.CJC_Source = "Built-In" | |||
| Configuration_AI_Thermocouple 13.CJC_Value = "10,000000" | |||
| Configuration_AI_Thermocouple 14.Maximum = "250,000000" | |||
| Configuration_AI_Thermocouple 14.Minimum = "-200,000000" | |||
| Configuration_AI_Thermocouple 14.Type = "K" | |||
| Configuration_AI_Thermocouple 14.CJC_Source = "Built-In" | |||
| Configuration_AI_Thermocouple 14.CJC_Value = "25,000000" | |||
| r53 | Configuration_AI_NI9219_Resistance.<size(s)> = "7" | ||
| Configuration_AI_NI9219_Resistance 0.Maximum = "800,000000" | |||
| r37 | Configuration_AI_NI9219_Resistance 0.Minimum = "0,000000" | ||
| r53 | Configuration_AI_NI9219_Resistance 0.Configuration = "4-Wire" | ||
| r37 | Configuration_AI_NI9219_Resistance 0.CurrentExcitationSource = "Internal" | ||
| Configuration_AI_NI9219_Resistance 0.CurrentExcitationValue = "0,000500" | |||
| Configuration_AI_NI9219_Resistance 0.RTD_Type = "Pt3750" | |||
| Configuration_AI_NI9219_Resistance 0.R0 = "1000,000000" | |||
| r53 | Configuration_AI_NI9219_Resistance 0.ABC = "<size(s)=3> 1,224E-3 2,31E-4 3,938074E-9" | ||
| r37 | Configuration_AI_NI9219_Resistance 1.Maximum = "250,000000" | ||
| r53 | Configuration_AI_NI9219_Resistance 1.Minimum = "0,000000" | ||
| r37 | Configuration_AI_NI9219_Resistance 1.Configuration = "2-Wire" | ||
| Configuration_AI_NI9219_Resistance 1.CurrentExcitationSource = "Internal" | |||
| Configuration_AI_NI9219_Resistance 1.CurrentExcitationValue = "0,000500" | |||
| Configuration_AI_NI9219_Resistance 1.RTD_Type = "Pt3750" | |||
| Configuration_AI_NI9219_Resistance 1.R0 = "1000,000000" | |||
| r53 | Configuration_AI_NI9219_Resistance 1.ABC = "<size(s)=3> 1,224E-3 2,31E-4 3,938074E-9" | ||
| r37 | Configuration_AI_NI9219_Resistance 2.Maximum = "250,000000" | ||
| r53 | Configuration_AI_NI9219_Resistance 2.Minimum = "0,000000" | ||
| r37 | Configuration_AI_NI9219_Resistance 2.Configuration = "2-Wire" | ||
| Configuration_AI_NI9219_Resistance 2.CurrentExcitationSource = "Internal" | |||
| Configuration_AI_NI9219_Resistance 2.CurrentExcitationValue = "0,000500" | |||
| Configuration_AI_NI9219_Resistance 2.RTD_Type = "Pt3750" | |||
| Configuration_AI_NI9219_Resistance 2.R0 = "1000,000000" | |||
| Configuration_AI_NI9219_Resistance 2.ABC = "<size(s)=3> 3,81E-3 -6,02E-7 -6E-12" | |||
| Configuration_AI_NI9219_Resistance 3.Maximum = "250,000000" | |||
| r53 | Configuration_AI_NI9219_Resistance 3.Minimum = "0,000000" | ||
| r37 | Configuration_AI_NI9219_Resistance 3.Configuration = "2-Wire" | ||
| Configuration_AI_NI9219_Resistance 3.CurrentExcitationSource = "Internal" | |||
| Configuration_AI_NI9219_Resistance 3.CurrentExcitationValue = "0,000500" | |||
| Configuration_AI_NI9219_Resistance 3.RTD_Type = "Pt3750" | |||
| Configuration_AI_NI9219_Resistance 3.R0 = "1000,000000" | |||
| Configuration_AI_NI9219_Resistance 3.ABC = "<size(s)=3> 1,224312924E-3 2,308955523E-4 3,938074268E-9" | |||
| r41 | Configuration_AI_NI9219_Resistance 4.Maximum = "10500,000000" | ||
| Configuration_AI_NI9219_Resistance 4.Minimum = "0,000000" | |||
| Configuration_AI_NI9219_Resistance 4.Configuration = "2-Wire" | |||
| Configuration_AI_NI9219_Resistance 4.CurrentExcitationSource = "Internal" | |||
| Configuration_AI_NI9219_Resistance 4.CurrentExcitationValue = "0,000500" | |||
| Configuration_AI_NI9219_Resistance 4.RTD_Type = "Pt3750" | |||
| Configuration_AI_NI9219_Resistance 4.R0 = "1000,000000" | |||
| r53 | Configuration_AI_NI9219_Resistance 4.ABC = "<size(s)=3> 0,001224 0,000231 3,938074E-9" | ||
| r41 | Configuration_AI_NI9219_Resistance 5.Maximum = "250,000000" | ||
| r53 | Configuration_AI_NI9219_Resistance 5.Minimum = "0,000000" | ||
| r41 | Configuration_AI_NI9219_Resistance 5.Configuration = "2-Wire" | ||
| Configuration_AI_NI9219_Resistance 5.CurrentExcitationSource = "Internal" | |||
| Configuration_AI_NI9219_Resistance 5.CurrentExcitationValue = "0,000500" | |||
| Configuration_AI_NI9219_Resistance 5.RTD_Type = "Pt3750" | |||
| Configuration_AI_NI9219_Resistance 5.R0 = "1000,000000" | |||
| r53 | Configuration_AI_NI9219_Resistance 5.ABC = "<size(s)=3> 0,001224 0,000231 3,938074E-9" | ||
| r41 | Configuration_AI_NI9219_Resistance 6.Maximum = "250,000000" | ||
| r53 | Configuration_AI_NI9219_Resistance 6.Minimum = "0,000000" | ||
| r41 | Configuration_AI_NI9219_Resistance 6.Configuration = "2-Wire" | ||
| Configuration_AI_NI9219_Resistance 6.CurrentExcitationSource = "Internal" | |||
| Configuration_AI_NI9219_Resistance 6.CurrentExcitationValue = "0,000500" | |||
| Configuration_AI_NI9219_Resistance 6.RTD_Type = "Pt3750" | |||
| Configuration_AI_NI9219_Resistance 6.R0 = "1000,000000" | |||
| r53 | Configuration_AI_NI9219_Resistance 6.ABC = "<size(s)=3> 0,003810 -6,020000E-7 -6,000000E-12" | ||
| Configuration_AI_NI9219_Type.<size(s)> = "7" | |||
| Configuration_AI_NI9219_Type 0 = "RTD" | |||
| Configuration_AI_NI9219_Type 1 = "Resistance_Thermistor" | |||
| Configuration_AI_NI9219_Type 2 = "Thermocouple" | |||
| Configuration_AI_NI9219_Type 3 = "Resistance_RTD" | |||
| Configuration_AI_NI9219_Type 4 = "Resistance_RTD" | |||
| Configuration_AI_NI9219_Type 5 = "Resistance_RTD" | |||
| Configuration_AI_NI9219_Type 6 = "Resistance_RTD" | |||
| r39 | POS_Config.IP = "10.1.2.1" | ||
| POS_Config.Port = "502" | |||
| POS_AxesNames.<size(s)> = "3" | |||
| POS_AxesNames 0 = "X" | |||
| POS_AxesNames 1 = "Y" | |||
| POS_AxesNames 2 = "Z" | |||
| r44 | POS_Reference_Axes = "<size(s)=3> 1,000000 1,000000 308,000000" | ||
| POS_Limits_Axis1 = "<size(s)=2> 0 155" | |||
| r43 | POS_Limits_Axis2 = "<size(s)=2> 0 303" | ||
| POS_Limits_Axis3 = "<size(s)=2> 0 309" | |||
| r39 | POS_AxesFlipped.<size(s)> = "3" | ||
| POS_AxesFlipped 0 = "True" | |||
| POS_AxesFlipped 1 = "True" | |||
| POS_AxesFlipped 2 = "False" | |||
| Pos_MaxVelocity = "300" | |||
| Pos_MaxAcceleration = "15000" | |||
| Pos_MaxJerk = "140000" | |||
| r40 | Pos_DO_E-Stop_Index = "0" | ||
| r44 | Pos_DO_Setup_Index = "2" | ||
| r43 | ForceLimit_Axis3 = "<size(s)=1> 0,000000" | ||
| ForceLimit_Axis3_Text.<size(s)> = "1" | |||
| r42 | ForceLimit_Axis3_Text 0 = "" | ||
| r43 | ForceLimit_Axis3_AO_Limits = "<size(s)=2> 0,000000 100,000000" | ||
| r42 | ForceLimit_AI_Index = "0" | ||
| AirCooling_AI_Index = "1" | |||
| r55 | AirCooling_AO_Index = "0" | ||
| r37 | |||
| [DefaultValues] | |||
| WorkingStroke = "0" | |||
| r41 | MaxTemperature = "<size(s)=15> 50,000000 250,000000 250,000000 250,000000 250,000000 250,000000 250,000000 250,000000 250,000000 250,000000 250,000000 250,000000 250,000000 250,000000 250,000000" | ||
| r37 | MeasurementTime = "1" | ||
| NominalCurrent = "0" | |||
| TableControl = False | |||
| r41 | SensorsColor = "<size(s)=15> 16776960 16711680 16744448 16744640 16711935 10879142 8388863 8421631 423327 9567230 14869218 14869218 14869218 14869218 14869218" | ||
| Sensors+.<size(s)> = "15" | |||
| r37 | Sensors+ 0 = "True" | ||
| Sensors+ 1 = "True" | |||
| Sensors+ 2 = "True" | |||
| r53 | Sensors+ 3 = "False" | ||
| r40 | Sensors+ 4 = "False" | ||
| r37 | Sensors+ 5 = "False" | ||
| Sensors+ 6 = "False" | |||
| Sensors+ 7 = "False" | |||
| Sensors+ 8 = "False" | |||
| Sensors+ 9 = "False" | |||
| r41 | Sensors+ 10 = "False" | ||
| Sensors+ 11 = "False" | |||
| Sensors+ 12 = "False" | |||
| Sensors+ 13 = "False" | |||
| Sensors+ 14 = "False" | |||
| SensorsFunction.<size(s)> = "15" | |||
| r37 | SensorsFunction 0 = "Umgebungstemperatur" | ||
| SensorsFunction 1 = "Pr�flingstemperatur" | |||
| SensorsFunction 2 = "Temperatur 3" | |||
| SensorsFunction 3 = "Temperatur 4" | |||
| SensorsFunction 4 = "Temperatur 5" | |||
| SensorsFunction 5 = "Temperatur 6" | |||
| SensorsFunction 6 = "Temperatur 7" | |||
| SensorsFunction 7 = "Temperatur 8" | |||
| SensorsFunction 8 = "Temperatur 9" | |||
| SensorsFunction 9 = "Temperatur 10" | |||
| r41 | SensorsFunction 10 = "Temperatur 11" | ||
| SensorsFunction 11 = "Temperatur 12" | |||
| SensorsFunction 12 = "Temperatur 13" | |||
| SensorsFunction 13 = "Temperatur 14" | |||
| SensorsFunction 14 = "Temperatur 15" | |||
| r42 | ForceLimit_Z = "0" | ||
| r41 | MovingParameter.Velocity = "20,000000" | ||
| MovingParameter.Acceleration = "50,000000" | |||
| MovingParameter.Jerk = "140000,000000" | |||
| Learning_Steps.X = "1,000000" | |||
| Learning_Steps.Y = "1,000000" | |||
| Learning_Steps.Z = "1,000000" | |||
| r37 | |||
| [Pathes] | |||
| User = "C:\Work\CurrentTester\support\User.txt" | |||
| ReportsFolder = "C:\Work\CurrentTester\support\ResultData" | |||
| ProtocolsFolder = "\\orion\G K S - Test1\01_Access\Anlagen" | |||
| r59 | CurrentProfilesFolder = "\\orion\labview\CurrentTester\support\CurrentProfiles" | ||
| r37 | Applicants = "C:\Work\CurrentTester\support\Applicants.txt" | ||
| r66 | Note = "C:\Work\CurrentTester\support\Note.txt" | ||
| r37 | |||
| [Report] | |||
| FileNameFormat = "%s_TestResults.txt" | |||
| ReportNameFormat = "%s_TestReport_%s.xlsx" | |||
| ReportTemplate_German = "C:\Work\CurrentTester\support\ReportTemplates\TemplateGerman.xlsx" | |||
| ReportTemplate_English = "C:\Work\CurrentTester\support\ReportTemplates\TemplateEnglish.xlsx" | |||
| [Protocol] | |||
| ProtocolNameFormat = "%s_A%d_Report_%s.docx" | |||
| ProtocolTemplate_German = "C:\Work\CurrentTester\support\ReportTemplates\ProtocolTemplateGerman.dotx" | |||
| ProtocolTemplate_English = "C:\Work\CurrentTester\support\ReportTemplates\ProtocolTemplateEnglish.dotx" | |||
| ProtocolComment_German = "Alle Messungen sind mit einem galvanisch isoliertem Thermosensor Type K durchf�hrt worden.\0ADie Testergebnisse und Auswertungen beziehen sich ausschlie�lich auf die Muster, die zu diesem Test unter Laborbedingungen verwendet wurden und auf den verwendeten Testaufbau!" | |||
| ProtocolComment_English = "All measurements were carried out with a galvanically isolated Type K thermal sensors.\0AThe test results and evaluations refer exclusively to the samples that were used for this test under laboratory conditions and to the test setup used!" | |||
| ProtocolDataFolderName = "Bilder|Messungen" | |||
| r57 | ProtocolFolderFormat = "%s_%s_Stromtest" | ||
| r37 | |||
| [StateMessages] | |||
| r64 | Info.<size(s)> = "32" | ||
| r37 | Info 0 = "Aktivierter Not-Halt oder eine T�r steht offen! Ein Teststart ist nicht m�glich" | ||
| Info 1 = "Zum Anlegen eines neuen Tests "Neuer Test" klicken" | |||
| Info 2 = "Grunddaten anlegen oder bestehenden Test �ffnen" | |||
| Info 3 = "Testdaten anlegen" | |||
| r64 | Info 4 = "Zur manuellen Stromeinstellung sollte die Schutzt�renfreigabe aufgehoben werden, zum Verfahren der Achsen sollte der Automatikbetrieb der Anlagensteuerung aktiviert werden!" | ||
| r37 | Info 5 = "Test geladen" | ||
| Info 6 = "Laufende Pr�fung..." | |||
| Info 7 = "Pr�fung erfolgreich abgeschlossen" | |||
| Info 8 = "Fehler aufgetreten!" | |||
| Info 9 = "Test abgebrochen!" | |||
| Info 10 = "Test abgebrochen! Maximale Temperatur wurde �berschritten" | |||
| Info 11 = "Test abgebrochen! Fehlerhafte Kontaktierung" | |||
| Info 12 = "Test abgebrochen! Messrate ist zu hoch" | |||
| Info 13 = "Test abgebrochen! Stromprofil- Generierung ist fehlgeschlagen" | |||
| Info 14 = "Test abgebrochen! Eingestellte Abschaltleistung der Stromquelle wurde erreicht" | |||
| Info 15 = "Test abgebrochen! Gemessener Strom liegt au�erhalb des definierten Bereichs" | |||
| Info 16 = "Testprotokoll wird erstellt... Bitte warten" | |||
| Info 17 = "Testprotokoll erstellt" | |||
| Info 18 = "Der letzte Test ist geladen..." | |||
| r64 | Info 19 = "Testdaten zur Testberichterstellung laden" | ||
| Info 20 = "Testdaten werden geladen... Bitte warten" | |||
| Info 21 = "Testdaten zur Testberichterstellung ausw�hlen" | |||
| Info 22 = "Testbericht wird erstellt... Bitte warten" | |||
| Info 23 = "Testbericht erstellt" | |||
| Info 24 = "Test ist gespeichert" | |||
| Info 25 = "Testdaten werden ge�ndert... Bitte warten" | |||
| Info 26 = "Achsen werden initialisiert..." | |||
| Info 27 = "Referenzfahrt l�uft..." | |||
| Info 28 = "X-Achse wird referenziert..." | |||
| Info 29 = "Y-Achse wird referenziert..." | |||
| Info 30 = "Z-Achse wird referenziert..." | |||
| Info 31 = "Position wird angefahren..." | |||
| Result.<size(s)> = "32" | |||
| r37 | Result 0 = "Not-Halt" | ||
| Result 1 = "" | |||
| Result 2 = "Bereit" | |||
| Result 3 = "Bereit" | |||
| Result 4 = "Einrichtbetrieb" | |||
| Result 5 = "Bereit" | |||
| Result 6 = "Pr�fung l�uft" | |||
| Result 7 = "Pr�fung fertig" | |||
| Result 8 = "Fehler" | |||
| Result 9 = "Pr�fung Stop" | |||
| Result 10 = "Pr�fung Stop" | |||
| Result 11 = "Pr�fung Stop" | |||
| Result 12 = "Pr�fung Stop" | |||
| Result 13 = "Pr�fung Stop" | |||
| Result 14 = "Pr�fung Stop" | |||
| Result 15 = "Pr�fung Stop" | |||
| Result 16 = "Bereit" | |||
| Result 17 = "Bereit" | |||
| Result 18 = "Bereit" | |||
| Result 19 = "Bereit" | |||
| Result 20 = "Bereit" | |||
| Result 21 = "Bereit" | |||
| r44 | Result 22 = "Bereit" | ||
| r61 | Result 23 = "Bereit" | ||
| r64 | Result 24 = "Bereit" | ||
| Result 25 = "Bereit" | |||
| Result 26 = "" | |||
| r39 | Result 27 = "Einrichtbetrieb" | ||
| r44 | Result 28 = "Einrichtbetrieb" | ||
| r61 | Result 29 = "Einrichtbetrieb" | ||
| r64 | Result 30 = "Einrichtbetrieb" | ||
| Result 31 = "Einrichtbetrieb" | |||
| r37 | |||
| [DialogMessages] | |||
| r64 | Messages.<size(s)> = "13" | ||
| r37 | Messages 0 = "Achtung Einrichtbetrieb!\0AM�gliche Gefahren:\0A-Klemmgefahr\0A-Hei�e Oberfl�chen\0A-Lichtbogen" | ||
| r61 | Messages 1 = "Bitte achten Sie darauf, dass alle Eingabefelder in der gew�hlten Sprache sind" | ||
| Messages 2 = "Geben Sie die f�r die Testberichterstellung erforderlichen Daten ein. Bitte achten Sie darauf, dass alle Eingabefelder in der gew�hlten Sprache sind" | |||
| r64 | Messages 3 = "\0A\0A\0AF�r den ausgew�hlten Artikel sind mehrere Stromprofile verf�gbar, eine kombinierte Anzeige ist daher nicht m�glich!" | ||
| r37 | Messages 4 = "W�hlen Sie eine Testkonfigurationsdatei zum Laden aus" | ||
| Messages 5 = "W�hlen Sie einen Ordner aus, der die Testergebnisse zum Laden enth�lt" | |||
| r42 | Messages 6 = "W�hlen Sie einen ID-Ordner aus, der alle Testergebnisse zum Laden enth�lt" | ||
| r57 | Messages 7 = "Die Merkzetteldaten werden gel�scht!\0ABitte best�tigen Sie die Operation oder schlie�en Sie das Dialogfeld, um den Vorgang abzubrechen ..." | ||
| r60 | Messages 8 = "Sollen die Testmessdaten zur sp�teren Testberichtserstellung au�erhalb des Stromtesters in das unten stehende Verzeichnis im Netzwerk kopiert werden?" | ||
| r63 | Messages 9 = "Sollen die Testdaten ge�ndert, bestehende Verzeichnisse umbenannt und vorhandene Excel- Testprotokolle �berschrieben werden?" | ||
| r64 | Messages 10 = "W�hlen Sie Artikel zum Laden aus" | ||
| Messages 11 = "Soll das unten stehende Verzeichnis erstellt werden?" | |||
| Messages 12 = "Zur Achsensteuerung mit freigegebenen T�ren sollte der Zustimmtaster w�hrend der Bewegung gedr�ckt werden" | |||
| r63 | |||
| [Tips] | |||