r1 [Tester]
TesterType = "HSMP1"
TesterName = "Hochstrommessplatz 1"
MaxCurrent = 600
MaxTemperature = 250
SensorsEnable.<size(s)> = "10"
SensorsEnable 0 = "True"
SensorsEnable 1 = "True"
SensorsEnable 2 = "True"
SensorsEnable 3 = "True"
SensorsEnable 4 = "True"
SensorsEnable 5 = "False"
SensorsEnable 6 = "False"
SensorsEnable 7 = "False"
SensorsEnable 8 = "False"
SensorsEnable 9 = "False"
SensorsDescription.<size(s)> = "10"
SensorsDescription 0 = "Keithley: Ch6"
SensorsDescription 1 = "Keithley: Ch7"
SensorsDescription 2 = "Keithley: Ch8"
SensorsDescription 3 = "Keithley: Ch9"
SensorsDescription 4 = "Keithley: Ch10"
SensorsDescription 5 = ""
SensorsDescription 6 = ""
SensorsDescription 7 = ""
SensorsDescription 8 = ""
SensorsDescription 9 = ""
VoltageDescription.<size(s)> = "4"
VoltageDescription 0 = "Pr�flingsspannung [V]"
VoltageDescription 1 = "Shunt- Spannung [V]"
VoltageDescription 2 = "Strom [A]"
VoltageDescription 3 = "Widerstand [mOhm]"
CalibrationPassword = "48c8947f69c054a5caa934674ce8881d02bb18fb59d5a63eeaddff735b0e9801e87294783281ae49fc8287a0fd86779b27d7972d3e84f0fa0d826d7cb67dfefc"
[Hardware]
SimulateDevices = True
DI_E-Stop = "Dev1/port1/line0"
DI_Setup = ""
PowerSupply_MinCurrent = "1"
PowerSupply_Check = False
Measurement_Channels.<size(s)> = "12"
Measurement_Channels 0 = "102"
Measurement_Channels 1 = "104"
Measurement_Channels 2 = "106"
Measurement_Channels 3 = "107"
Measurement_Channels 4 = "108"
Measurement_Channels 5 = "109"
Measurement_Channels 6 = "110"
Measurement_Channels 7 = ""
Measurement_Channels 8 = ""
Measurement_Channels 9 = ""
Measurement_Channels 10 = ""
Measurement_Channels 11 = ""
ShuntResistance = 0,00006
Measurement_Check = False
DMM_VISAName = "COM1"
DMM_ContactLimits = "<size(s)=2> 0,0 50,0"
TemperatureGain = "<size(s)=10> 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000"
TemperatureOffset = "<size(s)=10> 0,000000 0,000000 0,000000 0,500000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000"
VoltageGain = "<size(s)=4> 1,000000 1,000000 1,000000 1,000000"
VoltageOffset = "<size(s)=4> 0,000000 0,000000 0,000000 0,000000"
AllowedContactFails = "2"
[SMP3]
PowerSupply_VISAName = "COM4"
PowerSupply_Address = "1"
PowerSupply_Baudrate = "9600"
[HSMP1]
PowerSupply_VISAName = "COM2"
PowerSupply_Address = "6"
PowerSupply_Baudrate = "9600"
DMM_Baudrate = "9600"
NI_USB6252_Out_LiftTable = "Dev1/port0/line5"
NI_USB6252_Out_SettingMode.<size(s)> = "2"
NI_USB6252_Out_SettingMode 0 = "Dev1/port0/line0"
NI_USB6252_Out_SettingMode 1 = "Dev1/port0/line1"
[DefaultValues]
WorkingStroke = "0"
MaxTemperature = "250"
MeasurementTime = "1"
NominalCurrent = "0"
TableControl = False
SensorsColor = "<size(s)=10> 16776960 16711680 16744448 16744640 16711935 10879142 8388863 8421631 423327 9567230"
Sensors+.<size(s)> = "10"
Sensors+ 0 = "True"
Sensors+ 1 = "True"
Sensors+ 2 = "True"
Sensors+ 3 = "True"
Sensors+ 4 = "True"
Sensors+ 5 = "False"
Sensors+ 6 = "False"
Sensors+ 7 = "False"
Sensors+ 8 = "False"
Sensors+ 9 = "False"
SensorsFunction.<size(s)> = "10"
SensorsFunction 0 = "Umgebungstemperatur"
SensorsFunction 1 = "Pr�flingstemperatur"
SensorsFunction 2 = "Temperatur 3"
SensorsFunction 3 = "Temperatur 4"
SensorsFunction 4 = "Temperatur 5"
SensorsFunction 5 = "Temperatur 6"
SensorsFunction 6 = "Temperatur 7"
SensorsFunction 7 = "Temperatur 8"
SensorsFunction 8 = "Temperatur 9"
SensorsFunction 9 = "Temperatur 10"
[Pathes]
User = "C:\Work\CurrentTester\support\User.txt"
ReportsFolder = "C:\Work\CurrentTester\support\ResultData_HSMP1"
CurrentProfilesFolder = "C:\Work\CurrentTester\support\CurrentProfiles"
[Report]
FileNameFormat = "%s_TestResults.txt"
ReportNameFormat = "%s_TestReport.xlsx"
ReportTemplate_German = "C:\Work\CurrentTester\support\ReportTemplates\TemplateGerman.xlsx"
ReportTemplate_English = "C:\Work\CurrentTester\support\ReportTemplates\TemplateEnglish.xlsx"
[StateMessages]
Info.<size(s)> = "17"
Info 0 = "Aktivierter Not-Halt oder eine T�r steht offen! Ein Teststart ist nicht m�glich"
Info 1 = "Zum Anlegen eines neuen Tests "Neuer Test" klicken"
Info 2 = "Grunddaten anlegen oder bestehenden Test �ffnen"
Info 3 = "Testdaten anlegen"
Info 4 = "Der Schl�sselschalter muss in die Position "Einrichten" gebracht werden um die Einrichtbuttons zu aktivieren oder in die Position "Automatik" um den Test starten zu k�nnen oder den Strom manuell einzustellen!"
Info 5 = "Test geladen"
Info 6 = "Laufende Pr�fung..."
Info 7 = "Pr�fung erfolgreich abgeschlossen"
Info 8 = "Fehler aufgetreten!"
Info 9 = "Test abgebrochen!"
Info 10 = "Test abgebrochen! Maximale Temperatur wurde �berschritten"
Info 11 = "Test abgebrochen! Fehlerhafte Kontaktierung"
Info 12 = "Test abgebrochen! Messrate ist zu hoch"
Info 13 = "Test abgebrochen! Stromprofil- Generierung ist fehlgeschlagen"
Info 14 = "Report wird erstellt... Bitte warten"
Info 15 = "Report erstellt"
Info 16 = "Der letzte Test ist geladen..."
Result.<size(s)> = "17"
Result 0 = "Not-Halt"
Result 1 = ""
Result 2 = "Bereit"
Result 3 = "Bereit"
Result 4 = "Einrichtbetrieb"
Result 5 = "Bereit"
Result 6 = "Pr�fung l�uft"
Result 7 = "Pr�fung fertig"
Result 8 = "Fehler"
Result 9 = "Pr�fung Stop"
Result 10 = "Pr�fung Stop"
Result 11 = "Pr�fung Stop"
Result 12 = "Pr�fung Stop"
Result 13 = "Pr�fung Stop"
Result 14 = "Bereit"
Result 15 = "Bereit"
Result 16 = "Bereit"
[DialogMessages]
Messages.<size(s)> = "2"
Messages 0 = "Achtung Einrichtbetrieb!\0AM�gliche Gefahren:\0A-Klemmgefahr\0A-Hei�e Oberfl�chen\0A-Lichtbogen"
Messages 1 = "W�hlen Sie eine Vorlage aus:"