r0 | [Tester] | ||
TesterType = "SMP3" | |||
TesterName = "Strommessplatz 3" | |||
MaxCurrent = 130 | |||
MaxTemperature = 250 | |||
SensorsEnable.<size(s)> = "10" | |||
SensorsEnable 0 = "True" | |||
SensorsEnable 1 = "True" | |||
SensorsEnable 2 = "True" | |||
SensorsEnable 3 = "True" | |||
SensorsEnable 4 = "False" | |||
SensorsEnable 5 = "False" | |||
SensorsEnable 6 = "False" | |||
SensorsEnable 7 = "False" | |||
SensorsEnable 8 = "False" | |||
SensorsEnable 9 = "False" | |||
SensorsDescription.<size(s)> = "10" | |||
SensorsDescription 0 = "NI-9210: Ch1" | |||
SensorsDescription 1 = "NI-9210: Ch2" | |||
SensorsDescription 2 = "NI-9210: Ch3" | |||
SensorsDescription 3 = "NI-9210: Ch4" | |||
SensorsDescription 4 = "NI-9219: Ch1" | |||
SensorsDescription 5 = "NI-9219: Ch2" | |||
SensorsDescription 6 = "NI-9219: Ch3" | |||
SensorsDescription 7 = "NI-9219: Ch4" | |||
SensorsDescription 8 = "" | |||
SensorsDescription 9 = "" | |||
VoltageDescription.<size(s)> = "4" | |||
r1 | VoltageDescription 0 = "Pr�flingsspannung [V]" | ||
VoltageDescription 1 = "Shunt- Spannung [V]" | |||
r0 | VoltageDescription 2 = "Strom [A]" | ||
VoltageDescription 3 = "Widerstand [mOhm]" | |||
CalibrationPassword = "48c8947f69c054a5caa934674ce8881d02bb18fb59d5a63eeaddff735b0e9801e87294783281ae49fc8287a0fd86779b27d7972d3e84f0fa0d826d7cb67dfefc" | |||
[Hardware] | |||
SimulateDevices = True | |||
DI_E-Stop = "PXI1Slot5/port0/line5" | |||
DI_Setup = "PXI1Slot5/port0/line4" | |||
PowerSupply_MinCurrent = "0" | |||
PowerSupply_Check = False | |||
Measurement_Channels.<size(s)> = "12" | |||
r1 | Measurement_Channels 0 = "PXI1Slot5/ai3" | ||
r0 | Measurement_Channels 1 = "PXI1Slot5/ai4" | ||
Measurement_Channels 2 = "NI9210/ai0" | |||
Measurement_Channels 3 = "NI9210/ai1" | |||
Measurement_Channels 4 = "NI9210/ai2" | |||
Measurement_Channels 5 = "NI9210/ai3" | |||
Measurement_Channels 6 = "NI9219/ai0" | |||
Measurement_Channels 7 = "NI9219/ai1" | |||
Measurement_Channels 8 = "NI9219/ai2" | |||
Measurement_Channels 9 = "NI9219/ai3" | |||
Measurement_Channels 10 = "" | |||
Measurement_Channels 11 = "" | |||
ShuntResistance = 0,001 | |||
Measurement_Check = False | |||
DMM_VISAName = "PXI1Slot3" | |||
r1 | DMM_ContactLimits = "<size(s)=2> 0,0 1,5" | ||
r0 | TemperatureGain = "<size(s)=10> 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000 1,000000" | ||
TemperatureOffset = "<size(s)=10> 0,000000 0,000000 0,000000 0,500000 0,000000 0,000000 0,000000 0,000000 0,000000 0,000000" | |||
VoltageGain = "<size(s)=4> 1,000000 1,000000 1,000000 1,000000" | |||
VoltageOffset = "<size(s)=4> 0,000000 0,000000 0,000000 0,000000" | |||
AllowedContactFails = "2" | |||
[SMP3] | |||
PowerSupply_VISAName = "COM4" | |||
PowerSupply_Address = "1" | |||
PowerSupply_Baudrate = "9600" | |||
r1 | [HSMP1] | ||
PowerSupply_VISAName = "COM2" | |||
PowerSupply_Address = "6" | |||
PowerSupply_Baudrate = "9600" | |||
DMM_Baudrate = "9600" | |||
NI_USB6252_Out_LiftTable = "Dev1/port0/line5" | |||
NI_USB6252_Out_SettingMode.<size(s)> = "2" | |||
NI_USB6252_Out_SettingMode 0 = "Dev1/port0/line0" | |||
NI_USB6252_Out_SettingMode 1 = "Dev1/port0/line1" | |||
r0 | [DefaultValues] | ||
WorkingStroke = "0" | |||
MaxTemperature = "80" | |||
MeasurementTime = "1" | |||
NominalCurrent = "0" | |||
TableControl = False | |||
SensorsColor = "<size(s)=10> 16776960 16711680 16744448 16744640 16711935 10879142 8388863 8421631 423327 9567230" | |||
Sensors+.<size(s)> = "10" | |||
Sensors+ 0 = "True" | |||
Sensors+ 1 = "True" | |||
Sensors+ 2 = "True" | |||
Sensors+ 3 = "True" | |||
Sensors+ 4 = "False" | |||
Sensors+ 5 = "False" | |||
Sensors+ 6 = "False" | |||
Sensors+ 7 = "False" | |||
Sensors+ 8 = "False" | |||
Sensors+ 9 = "False" | |||
SensorsFunction.<size(s)> = "10" | |||
SensorsFunction 0 = "Umgebungstemperatur" | |||
SensorsFunction 1 = "Pr�flingstemperatur" | |||
SensorsFunction 2 = "Temperatur 3" | |||
SensorsFunction 3 = "Temperatur 4" | |||
SensorsFunction 4 = "Temperatur 5" | |||
SensorsFunction 5 = "Temperatur 6" | |||
SensorsFunction 6 = "Temperatur 7" | |||
SensorsFunction 7 = "Temperatur 8" | |||
SensorsFunction 8 = "Temperatur 9" | |||
SensorsFunction 9 = "Temperatur 10" | |||
[Pathes] | |||
User = "C:\Work\CurrentTester\support\User.txt" | |||
r1 | ReportsFolder = "C:\Work\CurrentTester\support\ResultData_SMP3" | ||
r0 | CurrentProfilesFolder = "C:\Work\CurrentTester\support\CurrentProfiles" | ||
[Report] | |||
FileNameFormat = "%s_TestResults.txt" | |||
ReportNameFormat = "%s_TestReport.xlsx" | |||
ReportTemplate_German = "C:\Work\CurrentTester\support\ReportTemplates\TemplateGerman.xlsx" | |||
ReportTemplate_English = "C:\Work\CurrentTester\support\ReportTemplates\TemplateEnglish.xlsx" | |||
[StateMessages] | |||
Info.<size(s)> = "17" | |||
Info 0 = "Aktivierter Not-Halt oder eine T�r steht offen! Ein Teststart ist nicht m�glich" | |||
Info 1 = "Zum Anlegen eines neuen Tests "Neuer Test" klicken" | |||
Info 2 = "Grunddaten anlegen oder bestehenden Test �ffnen" | |||
Info 3 = "Testdaten anlegen" | |||
Info 4 = "Der Schl�sselschalter muss in die Position "Einrichten" gebracht werden um die Einrichtbuttons zu aktivieren oder in die Position "Automatik" um den Test starten zu k�nnen oder den Strom manuell einzustellen!" | |||
Info 5 = "Test geladen" | |||
Info 6 = "Laufende Pr�fung..." | |||
Info 7 = "Pr�fung erfolgreich abgeschlossen" | |||
Info 8 = "Fehler aufgetreten!" | |||
Info 9 = "Test abgebrochen!" | |||
Info 10 = "Test abgebrochen! Maximale Temperatur wurde �berschritten" | |||
Info 11 = "Test abgebrochen! Fehlerhafte Kontaktierung" | |||
Info 12 = "Test abgebrochen! Messrate ist zu hoch" | |||
Info 13 = "Test abgebrochen! Stromprofil- Generierung ist fehlgeschlagen" | |||
Info 14 = "Report wird erstellt... Bitte warten" | |||
Info 15 = "Report erstellt" | |||
Info 16 = "Der letzte Test ist geladen..." | |||
Result.<size(s)> = "17" | |||
Result 0 = "Not-Halt" | |||
Result 1 = "" | |||
Result 2 = "Bereit" | |||
Result 3 = "Bereit" | |||
Result 4 = "Einrichtbetrieb" | |||
Result 5 = "Bereit" | |||
Result 6 = "Pr�fung l�uft" | |||
Result 7 = "Pr�fung fertig" | |||
Result 8 = "Fehler" | |||
Result 9 = "Pr�fung Stop" | |||
Result 10 = "Pr�fung Stop" | |||
Result 11 = "Pr�fung Stop" | |||
Result 12 = "Pr�fung Stop" | |||
Result 13 = "Pr�fung Stop" | |||
Result 14 = "Bereit" | |||
Result 15 = "Bereit" | |||
Result 16 = "Bereit" | |||
[DialogMessages] | |||
Messages.<size(s)> = "2" | |||
Messages 0 = "Achtung Einrichtbetrieb!\0AM�gliche Gefahren:\0A-Klemmgefahr\0A-Hei�e Oberfl�chen\0A-Lichtbogen" | |||
Messages 1 = "W�hlen Sie eine Vorlage aus:" |